TEL50B
&
. . . engineered solutions for the transient environment™
PBX LOW VOLTAGE TELEPHONE PROTECTOR
APPLICATIONS
✔ Telcom Terminal Equipment
✔ Data/Telcom Interfaces
✔ Dedicated Fax & Modems
IEC COMPATIBILITY (EN61000-4)
✔ 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
✔ 61000-4-4 (EFT): 40A - 5/50ns
✔ 61000-4-5 (Surge): 8/20µs - 95A, L5(Line-Gnd)
FEATURES
✔ Designed for ±50 Volt (Peak) Telephone Lines
✔ 4 Wire, Line-to-Ground Protection
✔ Permanent Two-Stage Protection
✔ Subnanosecond Response Time
✔ Automatic Reset - Does Not Interupt Service
✔ Effective Against Lightning, Inductive Switching and ESD
TEL50E
TEL50B
TEL50E
MECHANICAL CHARACTERISTICS
✔ Weight: TEL50E - 142 grams, TEL50B - 28 grams (Approximate)
✔ Flammability Rating UL 94V-0
✔ Device Marking: Logo, Part Number & Terminal Designations
DESCRIPTION
The TEL50B/E is a two-stage transient voltage protector that provides primary
and secondary protection against lightning, inductive switching and electrostatic discharge (ESD) transient threats. The first stage diverts the transient
current through the ground terminal return path and the second stage clamps
the voltage to a safe level without interuption of service.
The TEL50B/E is designed to protect telcom lines from common mode (line-toground) transients. There are four (4) independent lines referenced to the
ground terminals.
1 www.protekdevices.com05049.R2 1/03

DEVICE CHARACTERISTICS
TEL50B
&
TEL50E
MAXIMUM RATINGS @ 25°C
Peak Operatiing Line Voltage (VOP)
Operating Line Current (I
)
O
Maximum Transient Voltage
Maximum Transient Current
(8/20µs waveform)
Operating & Storage Temperature
Response Time
INSTALLATION INSTRUCTIONS
There are five (5) terminals on both the line and equipment side of the
TEL50E - four telcom line terminals and one ground terminal. The ground
terminal, as shown on the label, is connected internally. A single ground
connection is sufficient. However, it is recommended that both ground
connections be used for a lower impedance path to earth. This connection can be made through the green AC power ground wire or a known
earth ground. The ground wire should be #14 stranded wire.
Incoming telcom lines are to cut or disconnected from the equipment to
insert the TEL50E product. The line side of the terminals are to be
connected to outside telephone or telecommunication lines that carry the
transient threats into the equipment to be protected. The equipment
side of the terminals are to be connected to the equipment to be
protected . The location of the product should be such that these wires
are as short as possible. A #18 or 20 gauge wire can be used for these
connections.
±50V
PEAK
200mA
10kV
10kA/Wire
40kA/Protector
-55°C to 100°C
< 1 nanosecond
ELECTRICAL CHARACTERISTICS @ 25°C
MAXIMUM
CLAMPING
VOLTAGE
(8/20µs)
MAXIMUM
LINE
THRUPUT
RESISTANCE
@ ±500A
V
C
VOLTS
R
OHMS
95 12 5 800
The TEL50B requires an edge connector interface for installation. A
standard 15 position edge connector can be use. When mounting or
wiring the connectors onto a printed circuit board, be sure that the
correct terminals are soldered. The line side of the board connections
are finger contacts 2 thru 5. The boards are conformal coated for limited
protection against moisture.
ProTek’s telcom line protector is designed with a short circuit failure
mode to give maximum protection. A fuse, PTC, fussable link, or circuit
breaker is recommended for each signal line on the input (line) side of
the protector for those applications that require an open circuit failure
mode.
Caution: A low DC resistance ground may not be indicative of a good
lightning ground. Lightning contains a broad spectrum of frequencies up to 1 MHz. A low impedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG
stranded wire. For wire lengths over 1.5 meters, there may be some
excessive line to earth potential under severe thunderstorm conditions.
For these applications, an additional protector may be necessary at the
equipment interface.
MAXIMUM
LEAKAGE
CURRENT
@ ±185V
I
D
µA
MAXIMUM
CAPACITANCE
@ 0V, 1MHz
OP
C
pF
05049.R2 1/03
2 www.protekdevices.com

PACKAGE OUTLINE & DIMENSIONS
TEL50E CASE OUTLINE TEL50B BOARD OUTLINE
TEL50B
&
TEL50E
1.125”
(30.2mm)
Adhesive Mylar Label
0.61” MAX
(15.5mm)
3.8” MAX
(95.5mm)
3.25”±0.015”
(82.6mm±0.38mm)
WARNING:
EQUIPMENT
124 GND3
Terminal Screw
#6 Screws
Terminal Strip
0.50” MAX (12.7mm)
3.0” MAX
(76.2mm)
LINE
21 4GND 3
2.25” MAX
(57.2mm)
Mounting
Hole for #8
Screw
1.19” MAX
(30.2mm)
EQUIPMENT
030” MAX
(7.6mm)
OUTPUT Connected to
Transmit/Receive Circuits
Note:
I/O contacts spaced at 0.156”
(3.96mm) centers.
Orientation Notch
5
2
GND
15
12
0.07”
(17.8mm)
1.90” MAX
LINE
(48.2mm)
CONTINUITY
INPUT OUTPUT
12
13
14
15
INPUT Connected to Line From
Outside World
5
4
3
2
ProTek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288
E-Mail: sales@protekdevices.com
Web Site: www.protekdevices.com
COPYRIGHT © ProTek Devices 2003
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC).
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing
engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
3 www.protekdevices.com05049.R2 1/03