Datasheet T-51410D104-FW-P-AG Datasheet (OPTREX)

Page 1
Rev.
Date
Page
Comment
OP T R E X
LCD Module Technical Specification
T-51410D104-FW-P-AG
First Edition
Mar. 28, 2002
Final Revision
******
Checked by (Quality Assurance Div.)
***The part number and specification are still tentative.
Checked by (Design Engineering Div.)
Prepared by (Production Div.)
Table of Contents
1. Applications................................................................................................................................................. 2
2. Features........................................................................................................................................................... 2
3. Mechanical Specifications................................................................................................................ 2
4. Mechanical Drawing TFT LCD Module............................................................................ 3
5. Input / Output Terminals................................................................................................................. 6
6. Absolute Maximum Ratings ............................................................................................................7
7. Electrical Characteristics.....................................................................................................................7
9. Optical Characteristics..................................................................................................................... 14
10. Reliability TEST .................................................................................................................................... 17
11. Block Diagram......................................................................................................................................... 18
Revision History
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 1/18
Page 2
1.Application
This data sheet applies to acolor TFT LCD module.
Module applies to OA product, car TV(must use Analog to Digital drive board), which require high quality flat panel display. If you must use in high reliability environment can’t over reliability test condition
Optrex assumes no responsibility for any damage resulting from the use of the device which dose not comply with the instructions and the precautions inthese specification sheet.
2. Features
. Amorphous silicon TFT LCD panel with back-light unit . Pixel in stripe configuration . Slim and compact, designed for O/A application
. Display Colors:262,144 colors . Optimum Viewing Direction:12 o’clock
. 3.3V LVDS interface standard: DS90CF364 as receiver . +3.3V DC supply voltage for TFT LCD panel driving . Backlight driving DC/AC inverter not included in this module . Wide Viewing Angle
3.Mechanical Specifications
Parameter Specifications Unit
Screen Size 26.4(diagonal) cm
10.4 (diagonal) inch
Display Format Display Colors 262,144
Active Area Pixel Pitch Pixel Configuration Stripe
Outline Dimension Weight 470(typ.), g
Back-light CCFL, 2 tubes Surface treatment Anti-glare and hard-coating Display mode Normally white
800×(R, G, B)×600
211.2(H)×158.4 (V)
0.264 (H)×0.264 (V)
243 (w)×185.1(H)×11(typ.) (D)
dot
mm mm
mm
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 2/18
Page 3
4.Mechanical Drawing of TFT-LCD Module
Unit: mm
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 3/18
Page 4
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 4/18
Page 5
5.Input Terminals
5-1) TFT-LCD Panel Driving
Connector type: Molex55177-1491
Pin No. Symbol Function Remark
1 VDD Power supply : +3.3V 2 VDD Power supply : +3.3V 3 GND 4 GND 5 IN0- Pixel data Transmission pair 0 (negative -) 6 IN0+ Pixel data Transmission pair 0 (positive +) 7 IN1- Pixel data Transmission pair 1 (negative -) 8 IN1+ Pixel data Transmission pair 1 (positive +)
9 IN2- Pixel data Transmission pair 2 (negative -) 10 IN2+ Pixel data Transmission pair 2 (positive +) 11 CLK- Sampling Clock (negative -) 12 CLK+ Sampling Clock (positive +) 13 GND 14 GND
Recommended Transmitter (DS90C*363 of National Semiconductor) to interface
Assignment:
Input
terminal
of DS
Symbol No. Symbol Function
TIN0 44 R0 Red pixel data (LSB) TIN1 45 R1 Red pixel data TIN2 47 R2 Red pixel data Tout0- No.5 : IN0­TIN3 48 R3 Red pixel data TIN4 1 R4 Red pixel data Tout0+ No.6 : IN0+ TIN5 3 R5 Red pixel data(MSB) TIN6 4 G0 Green pixel data (LSB) TIN7 6 G1 Green pixel data TIN8 7 G2 Green pixel data
TIN9 9 G3 Green pixel data Tout1- No.7 : IN1­TIN10 10 G4 Green pixel data TIN11 12 G5 Green pixel data(MSB) Tout1+ No.8 : IN1+ TIN12 13 B0 Blue pixel data(LSB) TIN13 15 B1 Blue pixel data TIN14 16 B2 Blue pixel data TIN15 18 B3 Blue pixel data TIN16 19 B4 Blue pixel data Tout2- No.9 : IN2­TIN17 20 B5 Blue pixel data(MSB) TIN18 22 NC No connection Tout2+ N0.10 : IN2+ TIN19 23 NC No connection TIN20 25 ENAB Compound Synchronization
CLK in 26 NCLK Data sampling clock TCLK out-
90C*363
Graphic controller output signal Output signal
symbol
signal
TCLK out+
To interface
terminal(Symbol)
No.11 : CLK IN­No.12 : CLK IN+
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 5/18
Page 6
Data stream of IN0-/+, IN1-/+ and IN2-/+
Graphic Controller Circuit
TTL parallel to LVDS
LVDS to TTL parallel
LCD InternalCircuit
IN0
IN1
RxOUT6 RxOUT5 RxOUT4 RxOUT3 RxOUT2
R5
B0
NC
IN2
G0
RxOUT13 RxOUT12 RxOUT11 RxOUT10 RxOUT9
B1
RxOUT13 RxOUT12 RxOUT11 RxOUT10 RxOUT9
ENAB
LVDS Interface Block Diagram
R0~R5 G0~G5 B0~B5
TIN0~TIN5 TIN6~TIN11 TIN12~TIN17
R4 R3 R2
G5 G4 G3
NC B5 B4
IN0­IN0+
IN1-
RxOUT1
R1 R0
RxOUT8
G2 G1
RxOUT8
B3 B2
RxOUT0
RxOUT7
RxOUT7
RxOUT0~RxOUT5 RxOUT6~RxOUT11 RxOUT12~RxOUT17
TIN18
NC
TIN19
NC
ENAB
CLK IN
TIN20
TCLK IN
Customer systemside
PLL
DS90C*363
IN1+ IN2-
IN2+
CLK­CLK+
PLL
DS90CF364
RxOUT18 RxOUT19 RxOUT20
CLKOUT
module side
5-2) Backlight driving
Connector type :“BHR-02VS-1” of Japan Solderless Terminal MFG Co. LTD
PIN NO. Symbol Description Remark
1 LV Ground White 2 HV Lamp power input Pink (or Gray) 3 HV Lamp power input Pink (or Gray)
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 6/18
Page 7
6.Absolute Maximum Ratings:
1234567
8
GND=0V, Ta=25
Parameters Symbol MIN. MAX. Unit Remark
Supply Voltage V Input Signals Voltage V Backlight Driving Voltage V Backlight Driving Frequency F Storage Temperature T
Operating Temperature T
DD
IN
L
L
ST
OP
-0.3 +4.0 V
-0.3 VDD+0.3 V Note 6-1
- 2000 V
0 100 KHz
-20 +60 0 +50
℃ ℃
Note 6-2
Note 6-1: LVDS signal Note 6-2: Humidity : 80% RH Max. at Ta£ 40℃.
Maximum wet-bulb temperature is at 39℃or less at Ta > 40℃and no
condensation.
7.Electrical Characteristics
7-1) Recommended Operating Conditions: GND = 0V,Ta = 25
Item Symbol Min. Typ. Max. Unit Remark Supply Voltage VDD 3.0 3.3 3.6 V Current Dissipation I LVDS Differential input high threshold V LVDS Differential input low threshold V Lamp Current I
Lamp Voltage V Lamp Initial Voltage V
Lamp Driving Frequency F
DD
TH TL
FL
L
SFL
L
Lamp power consumption 4 8 11 W Note 7-5 Lamp Life Time 30000 40000 Hrs Note 7-6 LCD Panel Life Time(MTBF) 50000 Hrs
- 370 430 mA Note 7-1
- - 100 mV Note 7-2
-100 - -
6.0 14.0 16.0 mA Note 7-3 Note 7-5
400 430 530 Vrms Note 7-3
- - 875 Vrms
at Ta=25°C
Note 7-4
- - 1300
at Ta=0°C
Note 7-4
30 55 60 KHz
Note 7-1 : To test the current dissipation of VDD, using the “color bars” testing pattern
shown as below
White
1.
Yellow
2.
Cyan
3.
Green
4.
Magenta
5.
Red
6.
Blue
7.
Black
8.
Idd current dissipation testing pattern
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 7/18
Page 8
Note 7-2 : Please refers to DS90CF364 specification by National Semiconductor
3 2 1
X,1
X,2
X,3
X,4
X,598
X,599
X,600
X,Y
0
Corporation.
This LCD module conforms to LVDS standard.
Note 7-3 : The back-light driving waveform should be as closed to sine-wave as possible.
In order to satisfy the quality of B/L , no matter use what kind of inverter , the
output lamp current must between Min. and Max. to avoid the abnormal display image caused by B/L.
Note 7-4 : Not including the efficiency of backlight DC/AC inverter Note 7-5 : Lamp current is measured with current meter for high frequency as shown below
TFT-LCD
Inverter
Module
~ A
* Pin 3 isVlow ** Current meter :
Yokogawa 2016-01
Lamp current dissipation testing configuration Note 7-6: The life time is determined as the time at which brightness of lamp is 50% compare
to that of initial value at the typical lamp current.
7-2) Input / Output signal timing chart (A) Vertical Timing
1
t
2
t
CLK
ENAB
R5~R0 G5~G B5~B0
3
3
t
t
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 8/18
Page 9
(B) Horizontal Timing
c
t
CLK
ENAB
R5~R0
3
t
4
t
797,Y 799,Y
G5~G0 B5~B0
CLK
ENAB R5‑R0 G5‑G0 B5‑B0
2,Y3,Y 4,Y 5,Y
1,Y
t 6
7,Y
6,Y
t 5
t 8 t 9
X,Y
t 7
VALID
DATA
798,Y 800,Y
VIH(Min):0.8V
VIL(Max):0.2V
Input Signal
CenterLevel:
0.5V
VIH(Min):0.8V
VIL(Max):0.2V
cc
cc
cc
cc
cc
a
CLK
Duty ( a ,b ) : 50 。モ 10%
T-51410D104-FW-P-AG
b
0.5V
cc
OPTREX CORPORATION
Page 9/18
Page 10
D) Timing Specifications
Item Symbol Min. Typ. Max. Unit Remark
Frame Cycling t1 604 X t3 628X t3 660 X t3 -
- 16.58 17.86 ms Vertical Display Period t2 600 X t3 600 X t3 600 X t3 ­Horizontal Scanning Time t3 844 X t5 1056 X t5 1064 X t5 -
26.3 26.4 ­Horizontal Display Period t4 - 800 X t5 - ­Clock Cycle t5 24.0 25.0 - ns Clock High Level Time t6 9.0 - - ns Clock Low Level Time t7 9.0 - - ns Hold time t8 4.0 - - ns Set-up time t9 5.0 - - ns
μ
s
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 10/18
Page 11
7-3) Display Color and Gray Scale Reference
Input Color Data
Color Red Green Blue
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (63)
Basic Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Colors Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Red (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (01) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (02) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0
Darker
Red
Green
Blue
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Red (61) 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (00) Green (01) Green (02)
Darker
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Green (61) Green (62) Green (63) Blue (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue (01) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue (02) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
Darker
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Blue (61) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 Blue (62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0
0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 11/18
Page 12
7-4) Pixel Arrangement
RGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGB3
rd Line
2
nd Line
1
st Line
600
th Line
599
th Line
598
th Line
RGBRGBRGBRGB1
st Pixel
800
th Pixel
1 Pixel=
RGB
The LCD module pixel arrangement is the stripe.
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 12/18
Page 13
8.)Power On Sequence
3.0 V
V
CC
0 s< t <35 ms
0 s< t <35 ms
Signal
2t
1
0<t
Backlight
1. The supply voltage for input signals should be same as V
3.0 V
1
CC.
2. When the power is off , please keep whole signals (Hsync, Vsync, CLK, Data) low level or high impedance
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 13/18
Page 14
9.) Optical Characteristics
500 mm +/- 50 mm
9-1) Specification:
Ta = 25
Parameter Symbol Condition MIN. TYP. MAX. Unit Remarks
Horizontal
Viewing Angle
Contrast Ratio CR
Response time
Luminance L Luminance Uniformity U 55 80 - % Note 9-5
White Chromaticity Cross Talk Ratio CTK - - 3.5 % Note 9-6
Vertical
Rise Tr - 15 50 ms
Fall Tf
θ ±
θ
(to 12
o’clock)
θ
(to 6
o’clock)
x 0.280 0.330 0.380 ­y 0.340 0.390 0.440 -
CR³10
Optimum
direction
θ=0° φ=0°
θ
=0°/
°
=0
φ
50 55 - deg Note 9-1
35 40 - deg
100 180 - - Note 9-2
310 350 -
±
55
- 25 50 ms
60
- deg
cd/
Note 9-4
Note 9-3
All the optical measurement shall be executed 30 minutes after backlight being turn-on. The optical characteristics shall be measured in dark room (ambient illumination on panel surface less than 1 Lux). The measuring configuration shows as following figure.
Photometer (TOPCON BM-5A or BM-7 fast)
Field = 2°
TFT-LCD module
DC/AC Inverter
Optical characteristics measuring configuration
Note 9-1`:The definitions of viewing angles are as follows.
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 14/18
Page 15
12 o’clock
3 o’clock
9 o’clock
6 o’clock
Lamp connector
B
Tr
Tf
q
f
Note 9-2 : The definition of contrast ratio
CR
=
Luminanceatgray level 0
Note 9-3:Topcon BM-5A luminance meter 2°field of view is used in the testing (after 30
minutes’ operation). The typical luminance value is measured at lamp current 14.0 mA.
Note 9-4: Definition of Response Time Trand Tf:
Luminanceatgray level 63
White White
100%
90%
rightness
10%
0%
Black
Note 9-5: The uniformity of LCD is defined as
The Minimum Brightness of the 9 testing Points
U =
The Maximum Brightness of the 9 testing
Points Luminance meter : BM-5A or BM-7 fast(TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module
The test pattern is white (Gray Level 63).
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 15/18
Page 16
25% 50% 75%
25%
50%
75%
Note 8-6: Cross Talk (CTK) =
YA: Brightness of Pattern A YB: Brightness of Pattern B Luminance meter : BM 5A (TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module
Pattern A
(GrayLevel31)
½YA-YB½
YA
YA
1/3 1/3 1/3
×
100%
Pattern B
(GrayLevel31, central
black boxexclusive)
YB
: Measuring Point (Aand B are at thesame point.)
T-51410D104-FW-P-AG
1/3 1/3 1/3
OPTREX CORPORATION
Black
(GrayLevel0)
Page 16/18
Page 17
10. Reliability Test
No Test Item Test Condition Remark
1 High Temperature Storage Test 2 Low Temperature Storage Test 3 Low Temperature Operation Test
High Temperature & High Humidity
4
Operation Test Thermal Cycling Test
5
(non-operating)
Vibration Test
6
(non-operating)
Shock Test
7
(non-operating)
Ta: ambient temperature
Ta = +60℃, 240 hrs Ta = -20℃, 240 hrs Ta = 0℃, 240 hrs Ta = +50℃, 80%RH, 240 hrs (No Condensation) 0
ßà+25℃ßà+60
1Hr 0.5Hr 1Hr Frequency:10 ~ 57 H
58~500Hz, 1G
Sweep time: 11 min Test Period: 3 hrs (1 hr for each direction of X, Y, Z)
80G, 6ms, X,Y, Z 1 times for each direction
, 50 Cycles
Amplitude:0.15 mm
Z ,
[Judgement Criteria]
Under the display quality test conditions with normal operation state , there should be no change which may affect practical display function.
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 17/18
Page 18
11.)Block Diagram
123
599
598
6004212400
Con o
C cu
G D
r
LVD
D
C
R5
G5
B5
………
ENAB CLK
Back-light(Lamp1)
VL1 VL2
ENAB CLK
IN0-/+ IN1-/+ IN2-/+
VDD
S Interface (
S90
364)
Power Module
R0 R1
G0 G11
B0 B1
tr l ir
ate
TFT-LCD
rive
Display Area
it
3
Source Driver
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 18/18
Loading...