8. Power Sequence.................................................................................................................................... 13
10. Reliability TEST .................................................................................................................................... 17
Module applies to OA product, car TV(must use Analog to Digital drive board), which
require high quality flat panel display. If you must use in high reliability environment can’t over
reliability test condition
Optrex assumes no responsibility for any damage resulting from the use of the device
which dose not comply with the instructions and the precautions inthese specification sheet.
2. Features
. Amorphous silicon TFT LCD panel with back-light unit
. Pixel in stripe configuration
. Slim and compact, designed for O/A application
. 3.3V LVDS interface standard: DS90CF364 as receiver
. +3.3V DC supply voltage for TFT LCD panel driving
. Backlight driving DC/AC inverter not included in this module
. Wide Viewing Angle
3.Mechanical Specifications
ParameterSpecificationsUnit
Screen Size26.4(diagonal)cm
10.4 (diagonal)inch
Display Format
Display Colors262,144
Active Area
Pixel Pitch
Pixel ConfigurationStripe
Outline Dimension
Weight470(typ.),g
Back-lightCCFL, 2 tubes
Surface treatmentAnti-glare and hard-coating
Display modeNormally white
800×(R, G, B)×600
211.2(H)×158.4 (V)
0.264 (H)×0.264 (V)
243 (w)×185.1(H)×11(typ.) (D)
dot
mm
mm
mm
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 2/18
Page 3
4.Mechanical Drawing of TFT-LCD Module
Unit:mm
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 3/18
Page 4
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 4/18
Page 5
5.Input Terminals
5-1) TFT-LCD Panel Driving
Connector type: Molex55177-1491
Pin No.SymbolFunctionRemark
1VDDPower supply : +3.3V
2VDDPower supply : +3.3V
3GND
4GND
5IN0-Pixel data Transmission pair 0 (negative -)
6IN0+Pixel data Transmission pair 0 (positive +)
7IN1-Pixel data Transmission pair 1 (negative -)
8IN1+Pixel data Transmission pair 1 (positive +)
ItemSymbolMin.Typ.Max.UnitRemark
Supply VoltageVDD3.03.33.6V
Current DissipationI
LVDS Differential input high thresholdV
LVDS Differential input low thresholdV
Lamp CurrentI
Lamp VoltageV
Lamp Initial VoltageV
Lamp Driving FrequencyF
DD
TH
TL
FL
L
SFL
L
Lamp power consumption4811WNote 7-5
Lamp Life Time30000 40000HrsNote 7-6
LCD Panel Life Time(MTBF)50000Hrs
-370430mANote 7-1
--100mVNote 7-2
-100--
6.014.016.0mANote 7-3
Note 7-5
400430530VrmsNote 7-3
--875Vrms
at Ta=25°C
Note 7-4
--1300
at Ta=0°C
Note 7-4
305560KHz
℃
Note 7-1 : To test the current dissipation of VDD, using the “color bars” testing pattern
shown as below
White
1.
Yellow
2.
Cyan
3.
Green
4.
Magenta
5.
Red
6.
Blue
7.
Black
8.
Idd current dissipation testing pattern
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 7/18
Page 8
Note 7-2 : Please refers to DS90CF364 specification by National Semiconductor
321
X,1
X,2
X,3
X,4
X,598
X,599
X,600
X,Y
0
Corporation.
This LCD module conforms to LVDS standard.
Note 7-3 : The back-light driving waveform should be as closed to sine-wave as possible.
In order to satisfy the quality of B/L , no matter use what kind of inverter , the
output lamp current must between Min. and Max. to avoid the abnormal
display image caused by B/L.
Note 7-4 : Not including the efficiency of backlight DC/AC inverter
Note 7-5 : Lamp current is measured with current meter for high frequency as shown below
TFT-LCD
Inverter
Module
~
A
* Pin 3 isVlow
** Current meter :
Yokogawa 2016-01
Lamp current dissipation testing configuration
Note 7-6: The life time is determined as the time at which brightness of lamp is 50%
compare
to that of initial value at the typical lamp current.
7-2) Input / Output signal timing chart
(A) Vertical Timing
1
t
2
t
CLK
ENAB
R5~R0
G5~G
B5~B0
3
3
t
t
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 8/18
Page 9
(B) Horizontal Timing
c
t
CLK
ENAB
R5~R0
3
t
4
t
797,Y 799,Y
G5~G0
B5~B0
CLK
ENAB
R5‑R0
G5‑G0
B5‑B0
2,Y3,Y 4,Y 5,Y
1,Y
t 6
7,Y
6,Y
t 5
t 8t 9
X,Y
t 7
VALID
DATA
798,Y 800,Y
VIH(Min):0.8V
VIL(Max):0.2V
Input Signal
CenterLevel:
0.5V
VIH(Min):0.8V
VIL(Max):0.2V
cc
cc
cc
cc
cc
a
CLK
Duty ( a ,b ) : 50 。モ 10%
T-51410D104-FW-P-AG
b
0.5V
cc
OPTREX CORPORATION
Page 9/18
Page 10
D) Timing Specifications
ItemSymbolMin.Typ.Max.Unit Remark
Frame Cyclingt1604 X t3628X t3660 X t3-
-16.5817.86ms
Vertical Display Periodt2600 X t3600 X t3600 X t3Horizontal Scanning Timet3844 X t51056 X t5 1064 X t5-
26.326.4Horizontal Display Periodt4-800 X t5-Clock Cyclet524.025.0-ns
Clock High Level Timet69.0--ns
Clock Low Level Timet79.0--ns
Hold timet84.0--ns
Set-up timet95.0--ns
1. The supply voltage for input signals should be same as V
3.0 V
1
CC.
2. When the power is off , please keep whole signals (Hsync, Vsync, CLK, Data) low level
or high impedance
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 13/18
Page 14
9.) Optical Characteristics
500 mm +/- 50 mm
9-1) Specification:
Ta = 25
ParameterSymbolConditionMIN.TYP.MAX.UnitRemarks
Horizontal
Viewing Angle
Contrast RatioCR
Response time
LuminanceL
Luminance UniformityU5580-%Note 9-5
White Chromaticity
Cross Talk RatioCTK--3.5%Note 9-6
Vertical
RiseTr-1550ms
FallTf
θ±
θ
(to 12
o’clock)
θ
(to 6
o’clock)
x0.280 0.330 0.380y0.340 0.390 0.440-
CR³10
Optimum
direction
θ=0°
φ=0°
θ
=0°/
°
=0
φ
5055-deg Note 9-1
3540-deg
100180--Note 9-2
310350-
±
55
-2550ms
60
-deg
cd/
Note 9-4
Note 9-3
㎡
℃
All the optical measurement shall be executed 30 minutes after backlight being turn-on. The
optical characteristics shall be measured in dark room (ambient illumination on panel surface
less than 1 Lux). The measuring configuration shows as following figure.
Photometer (TOPCON
BM-5A or BM-7 fast)
Field = 2°
TFT-LCD module
DC/AC Inverter
Optical characteristics measuring configuration
Note 9-1`:The definitions of viewing angles are as follows.
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 14/18
Page 15
12 o’clock
3 o’clock
9 o’clock
6 o’clock
Lamp connector
B
Tr
Tf
q
f
Note 9-2 : The definition of contrast ratio
CR
=
Luminanceatgray level 0
Note 9-3:Topcon BM-5Aluminance meter 2°field of view is used in the testing (after 30
minutes’ operation). The typical luminance value is measured at lamp current 14.0
mA.
Note 9-4: Definition of Response Time Trand Tf:
Luminanceatgray level 63
WhiteWhite
100%
90%
rightness
10%
0%
Black
Note 9-5: The uniformity of LCD is defined as
The Minimum Brightness of the 9 testing Points
U =
The Maximum Brightness of the 9 testing
Points
Luminance meter : BM-5A or BM-7 fast(TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
The test pattern is white (Gray Level 63).
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 15/18
Page 16
25%50%75%
25%
50%
75%
Note 8-6: Cross Talk (CTK) =
YA: Brightness of Pattern A
YB: Brightness of Pattern B
Luminance meter : BM 5A (TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
Pattern A
(GrayLevel31)
½YA-YB½
YA
YA
1/3
1/3
1/3
×
100%
Pattern B
(GrayLevel31, central
black boxexclusive)
YB
: Measuring Point (Aand B are at thesame point.)
T-51410D104-FW-P-AG
1/31/31/3
OPTREX CORPORATION
Black
(GrayLevel0)
Page 16/18
Page 17
10. Reliability Test
NoTestItemTestConditionRemark
1High Temperature Storage Test
2Low Temperature Storage Test
3Low Temperature Operation Test
High Temperature & High Humidity
4
Operation Test
Thermal Cycling Test
5
(non-operating)
Vibration Test
6
(non-operating)
Shock Test
7
(non-operating)
Ta: ambient temperature
Ta = +60℃, 240 hrs
Ta = -20℃, 240 hrs
Ta = 0℃, 240 hrs
Ta = +50℃, 80%RH, 240 hrs
(No Condensation)
0
℃
ßà+25℃ßà+60
1Hr0.5Hr1Hr
Frequency:10 ~ 57 H
58~500Hz, 1G
Sweep time: 11 min
Test Period: 3 hrs (1 hr for each direction of
X, Y, Z)
80G, 6ms, X,Y, Z
1 times for each direction
℃
, 50 Cycles
Amplitude:0.15 mm
Z ,
[Judgement Criteria]
Under the display quality test conditions with normal operation state , there should be no
change which may affect practical display function.
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 17/18
Page 18
11.)Block Diagram
123
599
598
6004212400
Con
o
C
cu
G
D
r
LVD
D
C
R5
G5
B5
………
ENAB
CLK
Back-light(Lamp1)
VL1
VL2
ENAB
CLK
IN0-/+
IN1-/+
IN2-/+
VDD
S Interface (
S90
364)
Power
Module
R0
R1
G0
G11
B0
B1
tr
l
ir
ate
TFT-LCD
rive
Display Area
it
3
Source Driver
T-51410D104-FW-P-AG
OPTREX CORPORATION
Page 18/18
Loading...