Datasheet T-51382D064J-FW-P-AC Datasheet (OPTREX)

Page 1
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 1/24
LCD Module Technical Specification
T-51382D064J-FW-P-AC
NO. ITEM PAGE
- Contents 1 1 Application 2 2 Features 2 3 Mechanical Specifications 2 4 Mechanical Drawing of TFT-LCD module 3 5 Input / Output Terminals 4 6 Absolute Maximum Ratings 6 7 Electrical Characteristics 6 8 Optical Characteristics 15 9 Handling Cautions 17
10 Reliability Test 18 11 Indication of Label 18 12 Block Diagram 19 13 Standard 20 14 Packing 23
Checked by (ACI Engineering Div.)
Checked by (Quality Assurance Div.)
Approved by (Production Div.)
Prepared by (Production Div.)
Type No.
Aug 12, 2002
OPTREX
First Edition
Final Revision
******
Page 2
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 2/24
1. Application
This product applies computer peripheral, industrial meter , image communication
and multi-media.
2. Features
. Compatible with VGA-480 , VGA-400 , VGA-350 and free format. . Pixel in stripe configuration
. Slim and compact . Display Colors : 262,144 colors
. Image Reversion : Up/Down and Left/Right . Active area / Outline area = 62.3 % . Viewing Direction : 6 o’clock . Backlight lamps are Replaceable . Wide Viewing Angle
3. Mechanical Specifications
Parameter Specifications Unit
Screen Size 6.4 (diagonal) inch
Display Format
640×R, G, B×480
dot
Active Area
129.6(H)×97.44 (V)
mm
Dot Pitch
0.0675 (H)×0.203 (V)
mm
Pixel Pitch
0.203 (H)×0.203 (V)
mm
Pixel Configuration Stripe
Outline Dimension See Mechanical Drawing mm
Weight 335±10 g
Page 3
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 3/24
4. Mechanical Drawing of TFT-LCD Module
Page 4
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 4/24
5. Input / Output Terminals
5-1) TFT-LCD Panel Driving
Pin No. Symbol Function Remark
1 GND Ground (0V) 2 CLK Clock Signal for Sampling Image Digital Data 3 Hsync Horizontal Synchronous Signal Note 5-1 4 Vsync Vertical Synchronous Signal Note 5-1 5 GND Ground (0V) 6 R0 Red Image Data Signal (LSB) 7 R1 Red Image Data Signal 8 R2 Red Image Data Signal
9 R3 Red Image Data Signal 10 R4 Red Image Data Signal 11 R5 Red Image Data Signal (MSB) 12 GND Ground (0V) 13 G0 Green Image Data Signal (LSB) 14 G1 Green Image Data Signal 15 G2 Green Image Data Signal 16 G3 Green Image Data Signal 17 G4 Green Image Data Signal 18 G5 Green Image Data Signal (MSB) 19 GND Ground (0V) 20 B0 Blue Image Data Signal (LSB) 21 B1 Blue Image Data Signal 22 B2 Blue Image Data Signal 23 B3 Blue Image Data Signal 24 B4 Blue Image Data Signal 25 B5 Blue Image Data Signal (MSB) 26 GND Ground (0V) 27 DENB Disable 28 VCC DC +5.0V Power Supply 29 VCC DC +5.0V Power Supply 30 R/L Horizontal Image Shift-direction Select Signal Note 5-2 31 U/D Vertical Image Shift-direction Select Signal Note 5-3
Note 5-1 : The TFT-LCD module is compatible with four kinds of VGA timing . They are
VGA-480 , VGA-400 , VGA-350 and freedom mode . The polarization of Hsync and Vsync determine the timings.
VGA-480 VGA-400 VGA-350 Freedom Mode
Hsync Polarization Negative Negative Positive Positive
Vsync Polarization Negative Positive Negative Positive
Page 5
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 5/24
Note 5-2 : R/L is the Right/Left shift signal. (1) R/L= High, U/D= Low (2) R/L= Low, U/D= Low
Note 5-3 : U/D is the Up/Down shift signal.
(1) R/L= High, U/D= Low (2) R/L= High, U/D= High
5-2) Backlight driving
Pin No Symbol Description Remark
1 VL1 Input terminal (Hi voltage side) 2 NC No Connection 3 VL2 Input terminal (Low voltage side) Note 5-4
Note 5-4 : Low voltage side of backlight inverter connects with ground of inverter circuits. 5-3) Input / Output Connector
(A) LCD module connector (Reference)
DF9A-31P-1V
(B) Backlight Connector
JST BHR-03VS-1 Pin No.: 3 Pitch: 4 mm
Red: High Voltage
White: Low Voltage
Page 6
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 6/24
6. Absolute Maximum Ratings:
GND=0V, Ta=25°C
Parameters SymbolMIN. MAX. Unit Remark
+5V Supply Voltage V
CC
0.0 +6.0 V
Input Signals Voltage V
sig
-0.3 VCC+0.3 V Note 6-1
Storage Temperature T
stg
-30 +70
°C
Operating Temperature T
opa
-20 +70
°C
Note 6-1 : Input signals include CLK , Hsync , Vsync , DENB , R[0:5] , G[0:5] and B[0:5].
7. Electrical Characteristics
7-1) Recommended Operating Conditions: A) Driving for TFT-LCD panel
GND = 0V, Ta = 25°C
Parameters Symbol Min. Typ. Max. Unit Remark
+5V Supply Voltage V
CC
+4.75 +5.0 +5.25 V
Supply Input Ripple Voltage V
CCRP
0.1 Vp-p VCC=+5V
Input Signals Voltage (High) V
IH
+2.6 V
Input Signals Voltage (Low) V
IL
+0.5 V
(B) Driving for backlight
Ta = 25°C
Item Symbol Min. Typ. Max. Unit Remark
Tube Current I
f
- 6 - mA
Tube Voltage V
L
- 380 - Vrms
Oscillation - 35 - KHz
Lamp Life Time - 20,000 - Hr
7-2) Power Consumption
Parameters Symbol Typ. Max. Unit Remark
+5V Current Dissipation I
CC
260 300 mA
Input Signals Current (High) I
IH
100
µA
VIH =+5V
Input Signals Current (Low) I
IL
100
µA
VIL =0V LCD Panel Power Consumption 1.3 W Note 7-1 Backlight Power Consumption 4.56 W Note 7-2
Note 7-1 : The power consumption of backlight is not included.
Note 7-2 : Backlight lamp power consumption is calculated by I
L
×
VL.
Page 7
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 7/24
7-3) Input / Output signal timing chart
Parameters Symbol Format Min. Typ. Max. Unit Note
Frequency Fc=1/Tc All 25.175 MHz Note 7-3
Clock High Time Tckh All 10 ns
Low Time Tckl All 10 ns Periodic = Line Thp All 31.778
µs
Note 7-3
Hsync 800 1024 clock Note 7-3
Pulse Width Thpw All 2 96 200 clock Back Porch Thbp All 2 48 64 clock
VGA-480 515 525 1024 line Note 7-3
Periodic = Frame Tvp VGA-400 447 449 1024 line Note 7-3
VGA-350 447 449 1024 line Note 7-3
Vsync Freedom
Mode
1024 line
Pulse Width Tvpw All 1 2 line Back Porch Tvbp All 1 64 line
Data Setup Time Tds All 10 ns
Hold Time Tdh All 10 ns Periodic = Line Tep All 800 1024 clock Pulse Width (H) Tepw All 2 640 800 clock
DENB VGA-480 480 480 line
Display Line No(V) Tvd VGA-400 400 400 line
VGA-350 350 350 line
Freedom
Mode
480 line
Horizontal Display Periodic Thd All 640 640 640 clock Hsync-CLK Phase Difference
Thc All 10 Tc-10 ns
Vsync-Hsync Phase Difference
Tvh All 1 Thp-1 clock
Note 7-3: Tc is the period of sampling clock. In case of low-frequency, the image-flicker may occur.
Page 8
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 8/24
7-4) Display Time Range
(1) Vertical Timing :
(2) Horizontal Timing :
Tvbp
Tvd
Vsync
Hsync
DENB
Tvp
Tvpw
Vsync
(Negative)
(Positive)
Tvh
Hsync
Tds
Thp
Tc
TcklTckh
Hsync
CLK
DENB
CLK
Thpw
Tep
Tepw = Thd
Hsync
(Negative)
(Positive)
Thc
CLK
Tdh
R0~R5
G0~G5
B0~B5
Thbp
Page 9
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 9/24
(3). Detail of Horizontal Timing :
(a) VGA-480 Mode (Hsync = Negative Polarization)
Item Description Clock Cycles Time
A Horizontal Width 96
3.813 µs
B Horizontal B-Porch 48
1.907 µs
C Horizontal Display 640
25.422 µs
D Horizontal F-Porch 16
0.636 µs
E Horizontal Total 800
31.778 µs
(b) VGA-400 Mode (Hsync = Negative Polarization)
Item Description Clock Cycles Time
A Horizontal Width 96
3.813 µs
B Horizontal B-Porch 48
1.907 µs
C Horizontal Display 640
25.422 µs
D Horizontal F-Porch 16
0.636 µs
E Horizontal Total 800
31.778 µs
(c) VGA-350 Mode (Hsync = Positive Polarization)
Item Description Clock Cycles Time
A Horizontal Width 96
3.813 µs
B Horizontal B-Porch 48
1.907 µs
C Horizontal Display 640
25.422 µs
D Horizontal F-Porch 16
0.636 µs
E Horizontal Total 800
31.778 µs
(d) Free Format (Hsync = Positive Polarization)
Item Description Clock Cycles Time
A Horizontal Width Note 7-3 ---
B Horizontal B-Porch Note 7-3 --­C Horizontal Display Note 7-3 --­D Horizontal F-Porch Note 7-3 ---
E Horizontal Total < 1024 ---
A B C D
E
Reset Horizontal Counter to Zer
o
Page 10
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 10/24
(4) Detail of Vertical Timing :
(a) VGA-480 Mode (Vsync = Negative Polarization)
Item Description Horizontal Lines Time
A Vertical Width 2
63.5 µs
B Vertical B-Porch 33 1.049 ms C Vertical Display 480 15.253 ms D Vertical F-Porch 10
317.8 µs
E Vertical Total 525 16.683 ms
(b) VGA-400 Mode (Vsync = Negative Polarization)
Item Description Horizontal Lines Time
A Vertical Width 2
63.5 µs
B Vertical B-Porch 35 1.112 ms C Vertical Display 400 12.711 ms D Vertical F-Porch 12
381.0 µs
E Vertical Total 449 14.268 ms
(c) VGA-350 Mode (Vsync = Positive Polarization)
Item Description Horizontal Lines Time
A Vertical Width 2
63.5 µs
B Vertical B-Porch 60 1.907 ms C Vertical Display 350 11.122 ms D Vertical F-Porch 37
1.176 µs
E Vertical Total 449 14.268 ms
(d) Free Format (Vsync = Positive Polarization)
Item Description Horizontal Lines Time
A Vertical Width Note 7-3 ---
B Vertical B-Porch Note 7-3 --­C Vertical Display Note 7-3 --­D Vertical F-Porch Note 7-3 ---
E Vertical Total < 1024 ---
A B C D
E
Reset Vertical Counter to Zer
o
Page 11
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 11/24
7-5) Horizontal Display Position
Horizontal display position depends on the signal of DENB and the input digital image. As the rising edge of DENB signal comes, LCD module will create a horizontal sampling start pulse. At this time, the source driver ICs begin to sample image data and transfer the digital image data to analogue image data by D/A inverters. Then send the analogue image signal to the right position of active display area of the LCD panel. If DENB is low, LCD module will set horizontal display position in default value.
Parameters Symbol Format Min. Typ. Max. Unit Remark
DENB Setup Time Tes All 10 Tc-10 ns
Hold Time Teh All 10 Tc-10 ns Pulse Width Tepw All 2 640 720 clock
DENB Horizontal VGA-480 144 clock
Keep Sampling Thss VGA-400 144 clock
At Start VGA-350 144 clock
“Low” Pulse Position Free
Format
128 192 clock Note 7-4
Hsync-DENB Phase Difference
The All 96 160 clock
Note 7-4: In free format condition (Hsync = Positive, Vsync = Positive), if DENB is low, the position of horizontal sampling start pulse depends on the seven control lines of HP[6:0] Lattice iSPLSI1032E-LT70 FPGA. The starting position is the count of { 128 + Data(HP[6:0]) } clock.
7-6) Vertical Display Position
Mode Hsync Vsync V-Start
Position
V-Display Remark
VGA-480 Negative Negative 34 480 lines VGA-400 Negative Positive 17 400 lines Note 7-5 VGA-350 Positive Negative 30 350 lines Note 7-6
Freedom
Mode
Positive Positive 24 480 lines
Note 7-5: As the format is VGA-400 (Hsync = Negative , Vsync = Positive) , LCD module will adjust the display area to the center of display . At this time , both of the upper and lower display areas have 40 blanking lines (the display color is black) . The actual display area is center 400 lines.
Page 12
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 12/24
Note 7-6: As the format is VGA-350 (Hsync = Negative, Vsync = Positive) , LCD module will adjust the display area to the center of display . At this time , both of the upper and lower display areas have 65 blanking lines (the display color is black) . The actual display area is center 350 lines.
7-7) Pixel Arrangement The LCD module pixel arrangement is the stripe.
40 Blanking Lines400 Display Lines40 Blanking Lines
RGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGBRGB3
rd Line2nd Line
1
st Line480th Line479th Line478th LineRGBRGBRGBRGB1st Pixel640th Pixel1 Pixel =RGB
65 Blanking Lines
35 0 Display Lines
65Blanking Line
s
Page 13
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 13/24
7-8) Display Color and Gray Scale Reference
Input Color Data
Color Red Green Blue
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
Basic Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Colors Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Red (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (01) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (02) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0
Darker
Red
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Red (61) 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green (01) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Green (02) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0
Darker
Green
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Green (61) 0 0 0 0 0 0 1 1 1 1 0 1 0 0 0 0 0 0 Green (62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 Green (63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Blue (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue (01) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue (02) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
Darker
Blue
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Brighter Blue (61) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 Blue (62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Page 14
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 14/24
7-9) Control Board Dip Switch Format
SW1
Item Condition Remark
SW 1-1 Vertical Shift (1 Line) Default (ON) SW 1-2 Vertical Shift (2 Line) Default (ON) SW 1-3 Vertical Shift (4 Line) Default (OFF)
SW 1-4 Vertical Shift (8 Line) Default (OFF) SW 1-5 Vertical Shift (16 Line) Default (OFF) SW 1-6 Vertical Shift (32Line) Default (ON)
SW2
Item Condition Remark
SW 2-1 Horizontal Shift (1 Line) Default (ON) SW 2-2 Horizontal Shift (2 Line) Default (ON) SW 2-3 Horizontal Shift (4 Line) Default (ON)
SW 2-4 Horizontal Shift (8 Line) Default (ON) SW 2-5 Horizontal Shift (16 Line) Default (OFF) SW 2-6 Horizontal Shift (32 Line) Default (OFF)
Page 15
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 15/24
8. Optical Characteristics
8-1) Specification:
Ta=25°C
Parameter Symbol Condition MIN. TYP. MAX. Unit Remarks
Horizontal θ ±
55
±
60
deg Note 8-3
θ
(to 12
o’clock)
35 40 degViewing
Angle
Vertical
θ
(to 6
o’clock)
CR>10
50 55 deg
Contrast Ratio CR 100 180 Note 8-1
Rise Tr 30 ms
Response time
Fall Tf
θ=0°
50 ms
Brightness 300 cd/m2Note 8-2
Lamp Life Time 20,000 hr
x 0.264 0.294 0.324 -
White Chromaticity
y 0.276 0.306 0.336 -
Cross Talk θ=0° 3 % Note 8-4
Luminance when LCD is White
Note 8-1 : CR =
Luminance when LCD is Black
Contrast Ratio is measured in optimum common electrode voltage. Note 8-2 : Topcon BM-7 (fast) luminance meter 2° field of view is used in the testing (after 20~30
minutes' operation).
Note 8-3 : The definitions of viewing angle diagrams :
Page 16
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 16/24
YA-YB
Note 8-4 : Cross Talk (CTK) =
YA
×
100%
YA : Brightness of Pattern A YB : Brightness of Pattern B
Pattern A
(Gray Level 46)
Pattern B
(Gray Level 46, central
black box exclusive)
: Testing Point (A and B are at the same point.
)
YA
YB
1/3 1/3 1/3
1/3 1/3 1/3
Black
(Gray Level 0
)
Page 17
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 17/24
9. Handling Cautions
9-1) Mounting of module
a) Please power off the module when you connect the input/output connector. b) Please connect the ground pattern of the inverter circuit surely. If the connection is not perfect, some following problems may happen possibly.
1.The noise from the backlight unit will increase.
2.The output from inverter circuit will be unstable.
3.In some cases a part of module will heat. c) Polarizer which is made of soft material and susceptible to flaw must be handled
carefully.
d) Protective film (Laminator) is applied on surface to protect it against scratches and
dirts. It is recommended to peel off the laminator before use and taking care of static electricity.
9-2) Precautions in mounting
a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled,
wipe it with soft dry cloth.
b) Wipe off water drops or finger grease immediately. Long contact with water may
cause discoloration or spots.
c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped
on hard surface. Please handle with care.
d) Since CMOS LSI is used in the module. So take care of static electricity and earth
yourself when handling.
9-3) Adjusting module
a) Adjusting volumes on the rear face of the module have been set optimally before
shipment.
b) Therefore, do not change any adjusted values. If adjusted values are changed, the
specifications described may not be satisfied.
9-4) Others
a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many
hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of
leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel.
Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet.
Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic
components. f) Please adjust the voltage of common electrode as material of attachment by 1
module.
9-5) Polarizer mark
a) The polarizer mark is to describe the direction of wide view angle film how to mach
up with the rubbing direction.
Page 18
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 18/24
10. Reliability Test
No Test Item Test Condition
1 High Temperature Storage Test Ta = +70°C, 240 hrs 2 Low Temperature Storage Test Ta = -30°C, 240 hrs 3 High Temperature Operation Test Ta = +70°C, 240 hrs 4 Low Temperature Operation Test Ta = -20°C, 240 hrs
5
High Temperature & High Humidity Operation Test
Ta = +60°C, 80%RH, 240 hrs
6
Vibration Test
(non-operating)
Frequency:10 ~ 57 HZ /Vibration Width :0.075mm
58-500 H/ / Gravity :9.8m/s
Sweep time: 11 minutes
Test period: 3 hrs for each direction of X, Y, Z
7
Shock Test
(non-operating)
Gravity :490m/s
Direction: ±X, ±Y, ±Z
Pulse Width :11ms,half sine wave
Ta: ambient temperature [Judgement Criteria] Under the display quality test conditions with normal operation state , there should be no
change which may affect practical display function.
11. Indication of Label
a) Indicated contents of the Lot number label
Lot number
Products number
Contents of lot number: 1st—Process area: class 1000 H
class 100K M 2nd~3rd—Module screen size (in inch): 1.8”18, 2.5”⇒25… 5th—Production year: 19999, 2000A, 2001⇒1… 6th—Production month: 1, 2, 3…9, A, B, C
7th~10th—Serial numbers: 0001~9999
b) Indicated contents of the Product number label
T-51382D064J-FW-P-AC MADE IN TAIWAN

XXXXXXXXXXXXXXXXXXXXX
Module Name of Optrex
Ex. T-51382D064J-FW-P-AC
Barcode Symbol
Barcode Number
Production Country
The Module Manufacture Location
OOO-OOOOOO
O16C6448AF
Page 19
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 19/24
12. Block Diagram
123
479
478
480123456
1920
Control Board
H
SYNC
VSYNC
DENB
CLK
R[5:0]
G[5:0]
B[5:0]
RL
UD
V
L
GND Backlight
IC V1IC V1 IC V2IC V2 IC V3IC V3 IC V4IC V4
IC H1 IC H2
IC V8 IC V7 IC V6 IC V5
TFT-LCD
Display Area
Backlight
V
L
GND
Page 20
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 20/24
13. Standard
13-1) Inspection condition
Viewing Angle (Major axis x)
θ < 45° inspection under non-operating condition θ < 5° inspection under operating condition
TFT-LCD Module
Back-Light Unit
35cm or more
Viewing Zone
13-2) Environment condition
Ambient Temperature: 25°C ±5°C
Ambient Humidity: 65±5%RH
Ambient Luminance: 20 watts fluorescent lamp (about 500 lux)
13-3) Sampling condition
Lot size: Number of products per model shipped in one day.
Sampling type: Normal inspection, single sampling
Sampling Level: Level II
Sampling method: ISO 2859 (Also known as MIL-STD-105E), unless
otherwise agreed in writing
13-4) Acceptance Quality Level (AQL)
Major defect: 0.65%
Minor defect: 1.5%
13-5) Inspection Instrument:
Pattern Generator: PVI digital pattern Generator.
DC Power supply: DC 12V
Luminance color meter: Topcon BM –7
Others : Micrometer , Microscope, Caliper.
Page 21
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 21/24
Item Specification/Description Classification Note
Display function No Display
Malfunction
Major*
Contrast ratio
(Black, White)
Out of spec. Major* 3
Line defect No obvious
Vertical and Horizontal line Defect in bright, dark & Colored.
Major*
Display
Inspection
(operating)
Point defect (Red, Green, Blue, Dark)
(1) Active area 7 Point
Major** 1
Dimension Outline Major* Bezel appearance Uneven/poor coating Major**
Scratch on the
polarizer
N=5 max
(W<0.1 or L<=10)
N=0
(W>0.1 or L>10)
Major** 2
Dent or Bubble on
the polarizer
N=5 max
(W<=5 and L<=0.1)
N disregard
(W<=0.1)
Major** 2
External
Inspection
(non-operating)
Foreign material
on polarizer
N=4 max
(W<=0.10 and L<=2.1)
N disregard
(W<=0.03 and L<=0.3)
Major** 2
External
Inspection
(non-operating)
Wrinkle on
polarizer
Serious wrinkle is not
allowed
2
(W-Width in mm, L-Length in mm, N-Number, D-Average Diameter in mm,) Remark: ”*” Major: Defect that is likely to result in failure or to reduce materially the usability of the product for the intended function.
“**” Minor: Defect that will not result in functioning problem with deviation as classified.
Item N Total
Bright
(R,G,B)
5
Dark
5
7
Page 22
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 22/24
Note: 1. (a)Bright point defect is defined as point defect of R,G,B with area >1/2 pixel
respectively.
(b)Bright point defect which is not visible by using 5% ND filter,is not counted as
a defect.
(c)Definition of distribution of point defect is as follows:
-min separation between point defect should be larger than 4mm.
(d)Definition of joined bright point defect is as follows:
-Three joined bright lot must be nil.
-Joined bright point is 3 pair max.
(e)Definition of joined dark point defect is as follows:
-Three jointed dark point must be nil.
-Coupling of one dark and one bright point in junction is counted as one dark and one bright spot.
-Two dark point in junction is counted as one dark point.
Note:2. The external inspection is conducted at the distance 35±5cm between the eyes
of inspector and the panel. The inspection area is defined as full screen.
Note:3. Luminance measurement for contrast ratio is at the distance 50±5cm between the
detective head and the panel. With ambient illuminance less than 1 lux. Contrast ratio is obtained at optimum view angle.
Page 23
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 23/24
14. Packing
Page 24
T-51382D064J-FW-P-AC (AC) No. 2002-0168 OPTREX CORPORATION Page 24/24
Revision History
Rev. Issued Date Revised Contents
1.0 Apr. 02, 2002 NEW
1.1 May. 22, 2002 Modify Page 7 : Absolute Maximum Ratings (Operating Temperature) Page 19 : Reliability Test Condition (High & Low Operating Temperature)
Loading...