Datasheet SY10E160, SY100E160 Datasheet (MICREL)

Page 1
12-BIT PARITY GENERATOR/CHECKER
SY10E160
SY100E160
FEATURES
■ Provides odd-HIGH parity of 12 inputs
■ Extended 100E V
EE range of –4.2V to –5.5V
■ Output register with Shift/Hold capability
■ 900ps max. D to Q, /Q output
■ Enable control
■ Asynchronous Register Reset
■ Differential outputs
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E160
■ Available in 28-pin PLCC package
BLOCK DIAGRAM
D
0
D
1
D
2
D
3
D
4
D
5
D
6
D
7
D
8
D
9
D D
EN
HOLD
S-IN
SHIFT
CLK CLK
10 11
1 2
R
0
MUX
1
SEL
0
1
MUX
SEL
D
R
DESCRIPTION
The SY10/100E160 are high-speed, 12-bit parity generator/checkers with differential outputs, for use in new, high-performance ECL systems. The output Q takes on a logic HIGH value only when an odd number of inputs are at a logic HIGH. A logic HIGH on the enable input (EN) forces the output Q to a logic LOW.
An additional feature of the E160 is the output register. Two multiplexers and their associated signals control the register input by providing the option of holding present data, loading the new parity data or shifting external data in. To hold the present data, the Hold signal (HOLD) must be at a logic LOW level. If the HOLD signal is at a logic HIGH, the data present at the Q output is passed through the first multiplexer. Taking the Shift signal (SHIFT) to a logic HIGH will shift the data at the S-IN pin into the output register. If the SHIFT signal is at a logic LOW, the output of the first multiplexer is then passed through to the register.
The register itself is clocked on the rising edge of CLK or CLK2 (or both). The presence of a logic HIGH on the reset pin (R) forces the register output Y to a logic LOW.
PIN CONFIGURATION
Q Q
Y
Y
D5 D6
D7
VEE
D8 D9
D10
D4
D3
D2
D1
25 24 23 22 21 20 19 26 27 28
1 2 3 4
567891011
PLCC
TOP VIEW
J28-1
EN
D1
VCCO
18 17 16 15 14 13 12
Q Q
V Y
Y V NC
1
CC
CCO
2
11
D
S-IN
HOLD
SHIFT
1
R
CLK
CLK1
Rev.: D Amendment: /0 Issue Date: February, 1998
Page 2
Micrel
SY10E160
SY100E160
PIN NAMES
Pin Function
D0–D11 Data Inputs S-IN Serial Data Input EN Enable, active LOW HOLD Hold, active LOW SHIFT Shift, active HIGH CLK1, CLK2 Clock Inputs R Reset Input Q, Q Direct Output Y, Y Register Output
CCO VCC to Output
V
TRUTH TABLE
Number of Output
HIGH Inputs Q
Even LOW
Odd HIGH
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
IH Input HIGH Current µA—
I
CLK1, CLK2 ——200——200——200 R — — 300 — — 300 — — 300 All Other Inputs — — 150 — — 150 — — 150
EE Power Supply Current mA —
I
10E — 82 98 — 82 98 — 82 98
100E — 82 98 — 82 98 — 94 113
2
Page 3
Micrel
SY100E160
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
PLH Propagation Delay to Output ps —
t tPHL D to Q 400 650 950 400 650 950 400 650 950
EN to Q 300 550 750 300 550 750 300 550 750 CLK to Y 275 500 700 275 500 700 275 500 700 R to Y 275 500 725 275 500 725 275 500 725
S Set-up Time ps —
t
D 1200 900 — 1200 900 — 1200 900 — HOLD 600 300 — 600 300 — 600 300 — S-IN 350 150 — 350 150 — 350 150 — SHIFT 500 250 — 500 250 — 500 250 —
H Hold Time ps —
t
D –400 –900 — –400 –900 — –400 –900 — HOLD 100 –300 — 100 –300 — 100 –300 — S-IN 300 –150 — 300 –150 — 300 –150 — SHIFT 200 –250 — 200 –250 — 200 –250 —
r Rise/Fall Time 300 450 650 300 450 650 300 450 650 ps —
t tf 20% to 80%
SY10E160
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY10E160JC J28-1 Commercial SY10E160JCTR J28-1 Commercial SY100E160JC J28-1 Commercial SY100E160JCTR J28-1 Commercial
3
Page 4
Micrel
28 LEAD PLCC (J28-1)
SY10E160
SY100E160
Rev. 03
MICREL-SYNERGY 3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
TEL + 1 (408) 980-9191 FAX + 1 (408) 914-7878 WEB http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
4
Loading...