QUAD DRIVER
SY100S313
FEATURES
■ Max. propagation delay of 800ps
■ Enable to Output max. of 950ps
■ IEE min. of –60mA
■ Extended supply voltage option:
VEE = –4.2V to –5.5V
■ Voltage and temperature compensation for
improved noise immunity
■ Internal 75KΩ input pull-down resistors
■ 50% faster than Fairchild 300K
■ Function and pinout compatible with Fairchild F100K
■ Available in 24-pin CERPACK and 28-pin PLCC
packages
BLOCK DIAGRAM
O
1a
D
a
D
b
D
c
D
d
E
O
2a
O
1a
O
2a
O
1b
O
2b
O
1b
O
2b
O
1c
O
2c
O
1c
O
2c
O
1d
O
2d
O
1d
O
2d
DESCRIPTION
The SY100S313 offers four drivers with two OR and two
NOR outputs, designed for use in high-performance ECL
systems. The four drivers are controlled by a common
Enable signal which is buffered to minimize input loading.
If the D inputs are not used, the Enable signal can be used
to drive sixteen 50Ω lines. All inputs have 75KΩ pulldown
resistors and all outputs are buffered.
PIN CONFIGURATIONS
1a
O
O2aOaV
D
a
12
D
b
13
V
EE
14
Top View
V
EES
15
E
16
D
c
17
D
d
18
1911201021922823724
2d
1d
o
O
PLCC
J28-1
1d
O
EES
EES
V
2a
1b
O
O2bO
5
6
O
2b
O
1b
V
CCA
1
V
CC
V
CC
2
2
O
1c
2
2c
O
25
1c
2c
2d
O
O
O
DdDcE
EE
V
DbD
a
19
O
O
O
O
O
O
1
1d
2d
2
3
1d
2d
2c
1c
Top View
Flatpack
4
F24-1
5
6
18
17
16
15
14
13
O
1a
O
2a
O
1a
O
2a
O
2b
O
1b
7248239221021112012
1c
2c
O
O
CC
V
CCA
V
1b
2b
O
O
PIN NAMES
Pin Function
Da – Dd Data Inputs (n-1...5)
E Enable Input
Ona – Ond Data Outputs
Ona – Ond Complementary Data Outputs
VEES VEE Substrate
CCA VCCO for ECL Outputs
V
Rev.: G Amendment: /0
1
Issue Date: July, 1999

Micrel
SY100S313
LOGIC EQUATION
O = D + E
O = D + E
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND
Symbol Parameter Min. Typ. Max. Unit Condition
IIH Input HIGH Current, All Inputs ——200 µAVIN = VIH (Max.)
EE Power Supply Current –60 –43 –20 mA Inputs Open
I
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Max. Min. Max. Min. Max. Unit Condition
PLH Propagation Delay 200 850 200 850 200 850 ps
t
tPHL Data to Output
PLH Propagation Delay 300 1000 300 1000 300 1000 ps
t
tPHL Enable to Output
TLH Transition Time 300 900 300 900 300 900 ps
t
tTHL 20% to 80%, 80% to 20%
PLCC
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Max. Min. Max. Min. Max. Unit Condition
PLH Propagation Delay 200 800 200 800 200 800 ps
t
tPHL Data to Output
PLH Propagation Delay 300 950 300 950 300 950 ps
t
tPHL Enable to Output
TLH Transition Time 300 900 300 900 300 900 ps
t
tTHL 20% to 80%, 80% to 20%
2

Micrel
TIMING DIAGRAM
SY100S313
INPUT
t
TRUE
OUTPUT
COMPLEMENT
NOTE:
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND
PHL
t
PLH
t
TLH
Propagation Delay and Transition Times
20%
50%
80%
0.7 ± 0.1 ns0.7 ± 0.1 ns
50%
80%
50%
t
PLH
t
PHL
20%
t
THL
–0.95V
–1.69V
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY100S313FC F24-1 Commercial
SY100S313JC J28-1 Commercial
SY100S313JCTR J28-1 Commercial
3

Micrel
28 LEAD PLCC (J28-1)
SY100S313
Rev. 03
MICREL-SYNERGY 3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
TEL + 1 (408) 980-9191 FAX + 1 (408) 914-7878 WEB http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
5