Page 1
查询SXI100-05S供应商
Features
Boxed Power Supplies with Screw
Terminal Block
Single- and Triple Output Models
EMI Compliance with EN 55022 and
FCC Part 15, Level B
Short Cirquit Protection
Overvoltage Protection
High Efficiency
Industrial Grade Components
2 Year Product Warranty
Switching Power Supplies
SXI Series 15 - 150 Watt
Models with Single Output
Ordercode Output Power, max Output Voltage Output Current max.
SXI 15-03S 3.3 VDC 3.0 A
SXI 15-05S
SXI 15-12S 12 VDC 1.3 A
SXI 15-24S 24 VDC 0.7 A
SXI 30-03S 3.3 VDC 6.0 A
SXI 30-05S
SXI 30-12S 12 VDC 2.6 A
SXI 30-24S 24 VDC 1.4 A
SXI 50-03S 3.3 VDC 10.0 A
SXI 50-05S
SXI 50-12S 12 VDC 4.2 A
SXI 50-24S 24 VDC 2.2 A
The SXI-series are very compact switching power supplies for cost critical
applications. They deliver 15 to 150 W of continuous power. Use of high
quality components and good thermal dissipation make them a very reliable product with a calculated MTBF up to 200’000 h.
15 Watt
30 Watt
50 Watt
5 VDC 3.0 A
5 VDC 6.0 A
5 VDC 9.5 A
SXI 100-05S 5 VDC 20.0 A
SXI 100-12S 100 Watt 12 VDC 8.4 A
SXI 100-24S 24 VDC 4.4 A
SXI 150-05S 5 VDC 30.0 A
SXI 150-12S 150 Watt 12 VDC 12.5 A
SXI 150-24S 24 VDC 6.5 A
http://www.tracopower.com Page 1
Page 2
Models with Multioutput
Ordercode Output P ower Outpu t1 Output 2 Output 3
Switching Power Supplies
SXI Series 15 - 150 Watt
(floating)
SXI 15-0522T
SXI 15-0533T 5 VDC/ 1.5 A +15 VDC/ 0.5 A –15 VDC /0.3 A
SXI 30-0522T
SXI 30-0533T 5 VDC/ 4.0 A +15 VDC/ 1.0 A –15 VDC /0.5 A
SXI 50-0522T
SXI 50-0522T 5 VDC/ 6.0 A +15 VDC/ 1.2 A –15 VDC /0.7 A
15 W att
30 W att
50 W att
5 VDC/ 1.5 A +12 VDC/ 0.6 A –12 VDC /0.4 A
5 VDC/ 4.0 A +12 VDC/ 1.2 A –12 VDC /0.6 A
5 VDC/ 6.0 A +12 VDC/ 1.5 A –12 VDC /0.8 A
Input Specifications
Input voltage range 170 – 264 VAC
Input frequency 47 – 63 Hz
Input current (at full load) SXI 15 0.24 A typ.
SXI 30 0.46 A typ.
SXI 50 0.75 A typ.
SXI 100 0.65 A typ.
SXI 150 1.00 A typ.
Inrush current at 25 °C (< 2ms) SXI 15/30 20 A typ.
SXI 50 28 A typ.
SXI 100/150 15 A typ.
Start-up time 100 ms max.
Output Specifications
Output voltage adjustment range – Single output models ± 10 %
– Mulioutput models (Out put 1) ± 5 %
(Output 2 & 3) ± 5 % (Factory set/ fixed)
Regulation – Input variation ± 0.2 % max.
– Load variation (10–90%) ± 0.5 % max.
Ripple and noise (20Mhz Bandwidth) 80 mV pk-pk max.
Output current limitation 120 – 140 % Inom.
Overload protection mode constant current
Over voltage protection (only ooutput 1) 110 – 130 % Vout nom.
Capacitive load 10’000 µF
All specifications valid at nominal input voltage, full load and +25° C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 2
Page 3
Switching Power Supplies
SXI Series 15 - 150 Watt
General Specifications
Temperature ranges – Operating – 10 ° C … + 60 ° C ambient temp. max.
– Derating above 50 °C – 4% / °C
– Storage (non operating) – 20 °C …+ 85 °C
Temperature coefficient 0.01 % / °C
Efficiency 70 – 80 % (depending on model)
Humidity (non condensing) 85 % rel max.
Switching frequency 100 kHz typ. (Puls width modulation PWM)
Hold-up time 50 ms typ.
Isolation voltage – Input/ Output 3‘ 000 VAC
– Input/ Case 1‘ 500 VAC
– Output/ Case 500 VAC
Reliability /calculated MTBF (MIL-HDBK-217E) > 200‘ 000 h @ 25°C
ELectromagnetic compatibility (EMC), Emissions
– Conducted RI suppression EN 55022, class B, FCC part 15, level B
Safety standards IEC 60950, EN 60950
Case material Stainless steel
All specifications valid at nominal input voltage, full load and +25° C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 3
Page 4
Outline Dimensions mm (inches)
Switching Power Supplies
SXI Series 15 - 150 Watt
SXI 15
Single output
SXI 30
Single output
(2.72 ±0.04)
±1
69
(2.72 ± 0.04)
± 1
69
(2.39)
60.8
(2.16)
54.8
(2.39)
60.8
10.2
(2.16)
54.8
(0.39)
9.8
30
± 1
(1.18 ± 0.04)
34
± 1
(1.34 ± 0.04)
(0.40)
+ Vout
– Vout
AC Ground
AC Live
AC Neutral
15 max.
(0.59)
+ Vout
– Vout
AC Ground
AC Live
AC Neutral
15 max.
(0.59)
8.5
(0.33)
7
(0.28)
84
(3.31 ± 0.04)
70.5
(2.78 ± 0.02)
51
± 0.5
(2.01 ± 0.02)
104
± 1
(4.09 ± 0.04)
±1
±0.5
M3 thread
M3 thread
(bottom)
35
(1.38)
20
(0.79)
M3 thread
(bottom)
± 0.5
55
(2.10 ± 0.02)
W eight:
180 g (0.40 lb)
10.5
SXI 50
Single output
(3.35 ± 0.04)
(2.58)
(2.22)
± 1
65.5
85
56.5
(1.30 ± 0.04)
(1.46 ± 0.04)
Specifications can be changed without notice
31
(1.22 ± 0.04)
35
(1.38 ± 0.04)
(0.41)
33 ±1
37 ±1
±1
±1
15 max.
(0.59)
+ Vout
– Vout
AC Ground
AC Live
AC Neutral
6
(0.24)
9.5
(0.37)
10.5
(0.41)
7
(0.28)
85
(3.35 ± 0.02)
M3 thread
88.5
(3.48 ± 0.02)
119
(4.69 ± 0.04)
105
(4.13 ± 0.02)
M3 thread
79 ±0.5
(3.11 ± 0.02)
±0.5
±0.5
±1
±0.5
8
(0.31)
18
(0.71)
M3 thread
(bottom)
± 0.5
(2.78 ± 0.02)
70.5
7.5
(0.29)
18
(0.71)
W eight:
200 g (0.44 lb)
W eight:
290 g (0.64 lb)
http://www.tracopower.com Page 4
Page 5
Outline Dimensions mm (inches)
Switching Power Supplies
SXI Series 15 - 150 Watt
SXI 100
Single output
SXI 150
Single output
(3.66 ±0.04)
±1
93
(3.66 ± 0.04)
93 ±1
(3.41)
86.5
(3.41)
88
14.4
(3.19)
81
12.5
(3.19)
82.5
(1.44 ± 0.04)
(1.56 ± 0.04)
(0.57)
44
± 1
(1.73 ± 0.04)
48
± 1
(1.89 ± 0.04)
(0.49)
36.5 ±1
39.5 ±1
+ Sense
+ Vout
– Vout
– Sense
AC Ground
AC Live
AC Neutral
+ Sense
+ Vout
– Vout
– Sense
AC Ground
AC Live
AC Neutral
25
(0.98)
19 max.
10
(0.39)
19 max.
(0.75)
10
(0.39)
(0.75)
33
(1.30)
37
(1.46)
(5.59 ± 0.02)
175
(6.89 ± 0.04)
M4 thread
132
± 0.5
(5.20 ± 0.02)
160
(6.30 ± 0.04)
115
(4.53 ± 0.02)
M4 thread
142
±0.5
±1
134.5
(5.30 ± 0.02)
±1
±0.5
±0.5
M4 thread
(bottom)
42
(1.65)
19
(0.75)
M4 thread
(bottom)
44
(1.73)
± 0.5
20
(0.79 ± 0.02)
15
(0.59)
W eight:
550 g (1.21 lb)
W eight:
650 g (1.43 lb)
10.2
(0.4)
12 max.
(0.47)
± 1
119
(4.69 ± 0.04)
SXI 15
M3 thread
(bottom)
34
(0.34)
16
(0.63)
W eight:
220 g (0.49 lb)
± 1
+ Vout 1
– Vout 1
+ Vout 2
Common 2/3
– Vout 3
AC Ground
AC Live
AC Neutral
39
(1.54)
± 0.5
73
(2.87 ± 0.02)
Triple output
(3.27 ±0.04)
±1
83
(2.82)
71.7
34
(1.34 ± 0.04)
M3 thread
25
(1.98)
73
± 0.5
(2.87 ± 0.02)
Specifications can be changed without notice
13
(0.51)
http://www.tracopower.com Page 5
Page 6
Outline Dimensions mm (inches)
Switching Power Supplies
SXI Series 15 - 150 Watt
SXI 30
Triple output
SXI 50
Triple output
(4.25 ±0.04)
±1
108
(3.31 ± 0.04)
± 1
84
(3.09)
78.5
(3.07)
78
(2.85)
72.5
12
10.2
(2.82)
71.7
(0.4)
35 ±1
(1.38 ± 0.04)
(0.47)
+ Vout 1
– Vout 1
+ Vout 2
Common 2/3
– Vout 3
AC Ground
AC Live
AC Neutral
26
12 max.
(0.47)
+ Vout 1
– Vout 1
+ Vout 2
Common 2/3
– Vout 3
AC Ground
AC Live
AC Neutral
12 max.
(0.47)
10.5
(0.41)
(1.02)
5
7
(0.28)
(0.2)
129
(5.08 ± 0.04)
110
(4.33 ± 0.02)
110
(4.33 ± 0.02)
151.5
± 1
(5.96 ± 0.04)
±1
±0.5
M3 thread
± 0.5
M3 thread
(bottom)
± 0.5
65
(2.56 ± 0.02)
7
(0.28)
18
(0.71)
M3 thread
(bottom)
45
(1.77)
W eight:
280 g (0.62 lb)
111
39
± 1
(1.54 ± 0.04)
30
(1.19)
5
7
(0.28)
32.5
(1.28)
(0.2)
103
(4.05 ± 0.02)
(4.37 ± 0.02)
M3 thread
±0.5
±0.5
19
(0.75)
W eight:
490 g (1.08 lb)
Specifications can be changed without notice
Jenatschstrasse 1
• CH-8002 Zurich
• Switzerland
Tel. +41-1284 2911
• Fax +41-1201 1168
• e -mail:
[email protected] • internet: http://www.tracopower.com
Rev . 02/01
Page 6