SPECIFICATIONS
No.
STK442-110 2000.06.05
1. Case Outline 14Pins (See attached outline drawing)
2. Function class AB 2 channels AF power amplifier
3. Application 70W audio use
4. Maximum Ratings / Ta=25deg.
Power Supply Voltage 1
Power Supply Voltage 2
Thermal Resistance Theta j-c Per one power TR 1.9
Junction Temperature Tj max 150 deg.
Operating Substrate Temperature Tc max 125 deg.
Storage Temperature Tstg
Available Time for Load
Short-circuit *4
5. Operating Characteristics
Tc=25deg.,RL =6ohm(Non-inductive Load),Rg=600ohm,VG=30dB
Output Power *1
THD *1 THD
Frequency
Characteristics *1
Input Impedance ri
Output Noise
Voltage *3
Quiescent
Current
Output Neutral
Voltage
*Specifications and information herein are subject to change without notice.
Note *1.1ch Drive
*2.All tests are measured using a constant-voltage supply unless otherwise specified.
*3.The output noise voltage is peak value of an average-reading meter with a rms value scale(VTVM).
A regulated AC supply(50Hz) should be used to eliminate the effects of AC primary line flicker
noise.
*4.Available time for load short-circuit and output noise voltage are measured using the specified
transformer power supply.
Specified Transformer Power Supply
Item Symbol Conditions Ratings Unit
No signal +-61.5 V
Signal ,R L=8ohm ,6ohm +-54 V
Vcc=+-38V,RL=6ohm,f=50Hz
PO=70W,1ch drive
Conditions *2 Ratings
f
(Hz)
0.4 70
1k 10 110
1k
10000uDBA40C
10000u
kohm
+
+
+Vcc
500ohm
500ohm
-Vcc
Item Symbol
Po1
Po2
fL ,fH
VNO
ICCO
VN
ts
V
(V)
(Equivalent to MG-250)
TENTATIVE
0.3 s
0.2 %
20 to 50k Hz
55
1.0
80 mA
-70 0 +70 mV
deg.
Unit
W
Sanyo Electric Co.,Ltd. Module Systems Division NO.1

Equivalent Block Diagram
Test Circuit
+Vcc
GND
/100v
1 2
+RE
-RE
-RE
+RE
NF
NF
IN
IN
3 4 5 6 7 8 9 10 11 12 13 14
/10v
/10v
Ch2 IN
GND
Ch1 IN
Ch2 OUT
GND
-Vcc
/100v
Ch1 OUT
SUB.GND
(*1)Metal Plate Cement Resistor 0.22ohm+-10%(5W)
No.2

Case Outline
Unit:mm
* No production described or contained herein are intended for use in surgical implants, life-support
systems, aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention
equipment and the like, the failure, of which may directly or indirectly cause injury, death or property loss
* Anyone purchasing any products described or contained herein for an above-mentioned use shall:
1. Accept full responsibility and indemnify and defend SANYO ELECTRIC CO.,LTD., its affiliates, subsidiaries
and distributors and all their officers and employees, jointly and severally, against any and all claims and
litigation and all damage, cost and expenses associated with such use:
2. Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on
SANYO ELECTRIC CO.,LTD., its affiliates, subsidiaries and distributors or any of their officers and employees
jointly or severally.
* Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not guaranteed
for volume production. SANYO believes its use or any infringements of intellectual property rights or other
rights of third parties.
This catalog provides information as of June,2000. Specifications and information herein are subject to change without notice.
No.3