TOSHIBA Field Effect Transistor Silicon N Channel MOS Type
SSM3K02F
SSM3K02F
High Speed Switching Applications
· Small package
· Low on resistance : Ron = 200 mΩ (max) (VGS = 4 V)
: Ron = 250 mΩ (max) (VGS = 2.5 V)
· Low gate threshold voltage: Vth = 0.6~1.1 V (VDS = 3 V, ID = 0.1 mA)
Maximum Ratings
Characteristics Symbol Rating Unit
Drain-source voltage VDS 30 V
Gate-source voltage V
Drain current
Drain power dissipation P
Channel temperature T
Storage temperature range T
(Ta ==== 25°C)
DC ID 1.0
Pulse I
±10 V
GSS
2.0
DP
200 mW
150 °C
-55~150 °C
ch
stg
D
A
Unit: mm
JEDEC TO-236MOD
JEITA SC-59
TOSHIBA 2-3F1F
Weight: 0.012 g (typ.)
Marking Equivalent Circuit
Handling Precaution
When handling individual devices (which are not yet mounted on a circuit board), be sure that the environment
is protected against electrostatic electricity. Operators should wear anti-static clothing, and containers and other
objects that come into direct contact with devices should be made of anti-static materials.
1
2003-03-27

SSM3K02F
Electrical Characteristics
Characteristics Symbol Test Condition Min Typ. Max Unit
Gate leakage current I
Drain-source breakdown voltage V
Drain cut-off current I
Gate threshold voltage V
Forward transfer admittance ïYfsï
Drain-source ON resistance R
Input capacitance C
Reverse transfer capacitance C
Output capacitance C
Switching time
Turn-on time ton ¾ 52 ¾
Turn-off time t
(Ta ==== 25°C)
Note: Pulse test
Switching Time Test Circuit
VGS = ±10 V, VDS = 0 ¾ ¾ ±5 mA
GSS
ID = 1 mA, VGS = 0 30 ¾ ¾ V
(BR) DSS
VDS = 30 V, VGS = 0 ¾ ¾ 1 mA
DSS
VDS = 3 V, ID = 0.1 mA 0.6 ¾ 1.1 V
th
VDS = 3 V, ID = 0.5 A (Note) 1.5 ¾ ¾ S
ID = 0.5 A, VGS = 4 V (Note) ¾ 140 200
DS (ON)
VDS = 10 V, VGS = 0, f = 1 MHz ¾ 115 ¾ pF
iss
VDS = 10 V, VGS = 0, f = 1 MHz ¾ 24 ¾ pF
rss
oss
off
= 0.5 A, VGS = 2.5 V (Note) ¾ 180 250
I
D
VDS = 10 V, VGS = 0, f = 1 MHz ¾ 60 ¾ pF
VDD = 15 V, ID = 0.5 A,
V
= 0~2.5 V, RG = 4.7 W
GS
¾ 80 ¾
mW
ns
Precaution
Vth can be expressed as voltage between gate and source when low operating current value is ID = 100 mA for this
product. For normal switching operation, V
voltage than V
th
.
GS (ON)
(Relationship can be established as follows: V
Please take this into consideration for using the device.
V
recommended voltage of 2.5 V or higher to turn on this product.
GS
requires higher voltage than Vth and V
GS (off)
< Vth < V
GS (ON)
)
requires lower
GS (off)
2
2003-03-27

SSM3K02F
Figure 1 25.4 mm ´´´´ 25.4 mm ´´´´ 1.6 t (a Cu pad of 0.8 mm2 area)
4
2003-03-27

SSM3K02F
RESTRICTIONS ON PRODUCT USE
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
000707EA
5