Benefits Features
• Many material platforms and device form factors give engineers more design flexibility
• Compatible with high-volume electronics assembly
• Assists in meeting regulatory requirements
• Low resistance devices increase battery operating time
• RoHS compliant
• Lead free versions of all devices are available
• Broad range of resettable devices available
• Current ratings from 1.1A to 13A
• Voltage ratings from 6V to 30V
• Agency recognition, UL, CSA, TÜV
• Fast time-to-trip
• Low resistance
Applications
• Mobile phone and smart phone battery packs
• Tablet PC battery packs
• Mobile radio battery packs
• Computer battery packs
• Digital camera battery packs
• Portable media player battery packs
• Power tools (charge line)
12
199
Page 2
Application Selection Guide for Strap Battery Devices
The guide below lists PolySwitch strap battery devices which are typically used in these applications. The following pages contain the specifications for the part numbers recommended below. Once a device is selected, the user should evaluate and test each product for its intended application.
PolySwitch Resettable Devices — Key Device Selection Criteria
Protection Application
Mobile phone battery packs Li-ion Surface Mount refer to Surface-mount section of this catalog
Cordless phone battery packs NiMH Cylindrical VLP210F ––
Mobile radio battery packs NiMH Cylindrical LR4-380F ––
Computer battery packs NiMH Cylindrical LR4-900F ––
Camcorder battery packs NiMH or Li-ion Prismatic VLP270F VTP210GF
PDA battery packs Li-ion Prismatic VLP220F VLR175F Power tools (charge line) NiCd, NiMH or Li-ion Cylindrical custom LR4 custom VTP
Additional Comments
Li-ion Cylindrical LR4-1300SSF ––
Installation Method Lowest Resistance LowestThermal Cut-off
Prismatic MXP370BD VLR175F
SRP175F
SRP350F
Prismatic Consult local Rep Consult local Rep
LR4-380F ––
12
Table B1
Hold Current (A) 85°C 90°C 90°C 120°C 125°C 125°C
1.10 ——16V/0.054Ω ———
1.20 — 16V/0.053Ω ——15V/0.123Ω —
1.70 12V/0.025Ω — 16V/0.041Ω ———
1.75 12V/0.024Ω 16V/0.040Ω 16V/0.040Ω — 15V/0.070Ω —
1.90 ———6V/0.010Ω — 15V/0.056Ω
2.00 ————30V/0.045Ω —
2.10 — 16V/0.024Ω 16V/0.024Ω ———
2.20 — 16V/0.023Ω ————
2.30 12V/0.015Ω —————
2.60 —————15V/0.031Ω
2.70 — 16V/0.015Ω ————
3.50 ————30V/0.024Ω —
3.70 ———6V/0.013Ω ——
3.80 —————15V/0.020Ω
4.20 ————30V/0.018Ω —
4.50 —————20V/0.016Ω
5.50 —————20V/0.013Ω
6.00 —————20V/0.011Ω
7.30 —————20V/0.009Ω
9.00 —————20V/0.008Ω
13.00 —————20V/0.006Ω
Product Series - Current Rating, Voltage Rating / Typical Resistance for Strap Battery Devices
VLR VLP VTP MXP SRP LR4
Typical ActivationTemperature
200
RoHS Compliant, ELV Compliant
Page 3
Table B2
Part Number Amps
85°C Typical Activation VLR*
VLR170F 3.5 2.9 2.4 1.84 1.70 1.2 1.0 0.7 0.3 —— VLR170LF 3.5 2.9 2.4 1.84 1.70 1.2 1.0 0.7 0.3 —— VLR170UF 3.5 2.9 2.4 1.84 1.70 1.2 1.0 0.7 0.3 —— VLR175F 3.5 2.9 2.4 1.87 1.75 1.3 1.0 0.8 0.3 —— VLR175LF 3.5 2.9 2.4 1.87 1.75 1.3 1.0 0.8 0.3 —— VLR175UF 3.5 2.9 2.4 1.87 1.75 1.3 1.0 0.8 0.3 —— VLR230F 5.0 4.2 3.4 2.52 2.30 1.7 1.3 0.9 0.4 ——
90°C Typical Activation VLP*
VLP120UF 2.4 2.1 1.8 1.30 1.20 1.0 0.7 0.6 0.3 0.2 0.1 VLP175UF 3.2 2.7 2.3 1.70 1.75 1.2 1.0 0.8 0.5 0.2 0.1 VLP210F 4.3 3.6 2.9 2.31 2.10 1.6 1.3 1.0 0.6 0.3 0.1 VLP220F 4.5 3.8 3.0 2.45 2.20 1.7 1.4 1.1 0.7 0.3 0.1 VLP270F 5.6 4.7 4.0 3.05 2.70 2.2 1.7 1.4 0.9 0.4 0.1
VTP*
VTP110F 2.0 1.7 1.4 1.12 1.10 0.85 0.75 0.7 0.4 0.2 0.1 VTP170F 3.2 2.7 2.2 1.80 1.70 1.3 1.0 0.8 0.5 0.3 0.1 VTP170SSF 3.2 2.7 2.2 1.80 1.70 1.3 1.0 0.8 0.5 0.3 0.1 VTP170XF 3.2 2.7 2.2 1.80 1.70 1.3 1.0 0.8 0.5 0.3 0.1 VTP170XSF 3.2 2.7 2.2 1.80 1.70 1.3 1.0 0.8 0.5 0.3 0.1 VTP175F 3.2 2.7 2.2 1.84 1.75 1.3 1.0 0.8 0.5 0.3 0.1 VTP175LF 3.2 2.7 2.2 1.84 1.75 1.3 1.0 0.8 0.5 0.3 0.1 VTP210GF 4.1 3.5 2.9 2.26 2.10 1.6 1.3 1.0 0.7 0.4 0.1 VTP210SF 4.1 3.5 2.9 2.26 2.10 1.6 1.3 1.0 0.7 0.4 0.1
120°C Typical Activation MXP*
MXP190BB —— 2.6 — 1.90 —— 0.85 ——— MXP370BD —— 5.0 — 3.70 —— 1.90 ———
125°C Typical Activation SRP
SRP120F 1.9 1.7 1.5 1.20 1.17 1.0 0.9 0.8 0.6 0.5 0.4 SRP120LF 1.9 1.7 1.5 1.20 1.17 1.0 0.9 0.8 0.6 0.5 0.4 SRP120SF 1.9 1.7 1.5 1.20 1.17 1.0 0.9 0.8 0.6 0.5 0.4 SRP175F 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8 SRP175LF 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8 SRP175SF 2.5 2.2 2.0 1.75 1.68 1.4 1.3 1.2 1.0 0.9 0.8 SRP200F 3.1 2.8 2.5 2.00 1.97 1.7 1.5 1.4 1.2 1.0 0.9 SRP350F 5.3 4.8 4.3 3.50 3.44 3.0 2.7 2.5 2.1 1.8 1.7 SRP420F 6.3 5.7 5.1 4.20 4.11 3.6 3.3 3.0 2.6 2.2 2.1
LR4
LR4-190F 2.8 2.5 2.3 1.9 1.86 1.6 1.5 1.4 1.2 1.1 1.0 LR4-260F 3.8 3.4 3.1 2.6 2.54 2.2 2.0 1.9 1.7 1.4 1.3 LR4-260SF 3.8 3.4 3.1 2.6 2.54 2.2 2.0 1.9 1.7 1.4 1.3 LR4-380F 5.4 4.9 4.4 3.8 3.64 3.3 3.0 2.8 2.5 2.3 2.1 LR4-380XF 5.4 4.9 4.4 3.8 3.64 3.3 3.0 2.8 2.5 2.3 2.1 LR4-450F 6.5 5.8 5.3 4.5 4.38 3.9 3.6 3.3 2.9 2.6 2.4 LR4-550F 7.6 6.9 6.2 5.5 5.32 4.7 4.3 4.0 3.6 3.2 3.0 LR4-600F 8.7 7.8 7.1 6.0 5.86 5.2 4.7 4.4 3.9 3.4 3.2 LR4-600XF 8.7 7.8 7.1 6.0 5.86 5.2 4.7 4.4 3.9 3.4 3.2 LR4-730F 10.5 9.5 8.6 7.3 7.13 6.3 5.7 5.4 4.7 4.2 4.0 LR4-900F 12.7 11.4 10.0 9.0 8.50 7.5 6.8 6.2 5.5 4.9 4.5 LR4-1300SSF 17.9 16.2 14.5 13.0 12.40 11.1 10.3 9.5 8.6 7.7 7.2
* Product electrical characteristics determined at 25°C.
Thermal Derating for Strap Battery Devices [Hold Current (A) at Ambient Temperature (°C)]
Maximum Ambient Temperature
-40°C -20°C 0°C 20°C 25°C 40°C 50°C 60°C 70°C 80°C 85°C
PolySwitch Resettable Devices – Strap Battery Devices
12
RoHS Compliant, ELV Compliant
201
Page 4
% of Rated Hold andTrip Current
Temperature (˚C)
200
180
160
140
120
100
80
60
40
20
0
-50 -30-40 -10-20 20100 4030 6050 8070 90
A
A B
C
D
B
C
D
Figure B1 Thermal Derating Curve for Strap Battery Devices
A= LR4
Figure B1
B= SRP C= VTP,VLP, MXP D= VLR
Table B3 Electrical Characteristics for Strap Battery Devices
Part Number
(A)
I
H
(A)
I
V
T
MAX
(VDC)
85°C Typical Activation VLR*
VLR170F 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B3 VLR170LF 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B3 VLR170UF 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B5 VLR175F 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B3 VLR175LF 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B3 VLR175UF 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B5 VLR230F 2.30 5.0 12 100 2.5 10.00 5.0 0.012 0.018 0.036 B3
90°C Typical Activation VLP*
VLP120UF 1.20 3.6 16 60 1.6 7.00 5.0 0.039 0.067 0.134 B5 VLP175UF 1.75 3.9 16 60 1.6 8.75 5.0 0.030 0.050 0.100 B5 VLP210F 2.10 5.0 16 60 1.8 10.50 5.0 0.018 0.030 0.060 B2 VLP220F 2.20 5.3 16 60 1.8 11.00 5.0 0.017 0.029 0.058 B3 VLP270F 2.70 6.5 16 60 2.5 13.50 5.0 0.012 0.018 0.036 B3
I
MAX
(A)
P
D MAX
(W)
Max.Time-to-trip
(A) (s)
MIN
R
MAX
(Ω)
R
(Ω)
R
1MAX
(Ω)
Figure for
Dimensions
VTP*
VTP110F 1.10 2.7 16 100 1.3 5.50 5.0 0.038 0.070 0.140 B5 VTP170F 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B2
12
VTP170SSF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B7 VTP170XF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B3
202
VTP170XSF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B4 VTP175F 1.75 3.6 16 100 1.4 8.75 5.0 0.029 0.051 0.102 B3 VTP175LF 1.75 3.6 16 100 1.4 8.75 5.0 0.029 0.051 0.102 B3 VTP210GF 2.10 4.7 16 100 1.5 10.00 5.0 0.018 0.030 0.060 B3 VTP210SF 2.10 4.7 16 100 1.5 10.00 5.0 0.018 0.030 0.060 B4
120°C Typical Activation MXP*
MXP190BB 1.90 4.9 6 50 1.0 9.50 2.0 0.007 0.015 0.024 B12 MXP370BD 3.70 9.0 6 50 1.3 18.50 5.0 0.004 0.010 0.016 B12
* Product electrical characteristics determined at 25°C.
RoHS Compliant, ELV Compliant
Page 5
Table B3 Electrical Characteristics for Strap Battery Devices
A
B F
D E
C
B F
D E
A
C
A
B F
D E
C
PolySwitch Resettable Devices – Strap Battery Devices
Cont’d
Part Number
(A)
I
H
(A)
I
V
T
MAX
(VDC)
I
MAX
(A)
P
D MAX
(W)
Max.Time-to-trip
(A) (s)
MIN
R
MAX
(Ω)
R
(Ω)
R
1MAX
(Ω)
Figure for
Dimensions
125˚C Typical Activation SRP
SRP120F 1.20 2.7 15 100 1.2 6.00 5.0 0.085 0.160 0.220 B6 SRP120LF 1.20 2.7 15 100 1.2 6.00 5.0 0.085 0.160 0.220 B6 SRP120SF 1.20 2.7 15 100 1.2 6.00 5.0 0.085 0.160 0.220 B10 SRP175F 1.75 3.8 15 100 1.5 8.75 5.0 0.050 0.090 0.120 B6 SRP175LF 1.75 3.8 15 100 1.5 8.75 5.0 0.050 0.090 0.120 B6 SRP175SF 1.75 3.8 15 100 1.5 8.75 5.0 0.050 0.090 0.120 B10 SRP200F 2.00 4.4 30 100 1.9 10.00 4.0 0.030 0.060 0.100 B6 SRP350F 3.50 6.3 30 100 2.5 20.00 3.0 0.017 0.031 0.050 B6 SRP420F 4.20 7.6 30 100 2.9 20.00 6.0 0.012 0.024 0.040 B6
LR4
LR4-190F 1.90 3.9 15 100 1.2 9.5 5.0 0.0390 0.0720 0.102 B8 LR4-260F 2.60 5.8 15 100 2.5 13.0 5.0 0.0200 0.0420 0.063 B8 LR4-260SF 2.60 5.8 15 100 2.5 13.0 5.0 0.0200 0.0420 0.063 B9 LR4-380F 3.80 8.3 15 100 2.5 19.0 5.0 0.0130 0.0260 0.037 B8 LR4-380XF 3.80 8.3 15 100 2.5 19.0 5.0 0.0130 0.0260 0.037 B8 LR4-450F 4.50 8.9 20 100 2.3 22.5 5.0 0.0110 0.0200 0.028 B8 LR4-550F 5.50 10.5 20 100 2.8 27.5 5.0 0.0090 0.0160 0.022 B8 LR4-600F 6.00 11.7 20 100 2.8 30.0 5.0 0.0070 0.0140 0.019 B8 LR4-600XF 6.00 11.7 20 100 2.8 30.0 5.0 0.0075 0.0140 0.019 B8 LR4-730F 7.30 14.1 20 100 3.3 30.0 5.0 0.0060 0.0120 0.015 B8 LR4-900F 9.00 16.7 20 100 3.8 45.0 5.0 0.0060 0.0100 0.014 B8 LR4-1300SSF 13.00 21.2 20 100 4.5 50.0 10.0 0.0035 0.0065 0.009 B11
* Product electrical characteristics determined at 25°C.
Notes:
I
: Hold current: maximum current device will pass without interruption in 20°C still air unless otherwise specified.
H
I
: Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air unless otherwise specified.
T
V
: Maximum voltage device can withstand without damage at rated current.
MAX
I
: Maximum fault current device can withstand without damage at rated voltage.
MAX
P
: Power dissipated from device when in the tripped state in 20°C still air unless otherwise specified.
D
R
: Minimum resistance of device as supplied at 20°C unless other wise specified.
MIN
R
: Maximum resistance of device as supplied at 20°C unless other wise specified.
MAX
R
: Maximum resistance, measured at 20°C unless otherwise specified, of device one hour after being tripped the first time.
1MAX
Figure B2-B12 Dimension Figures for Strap Battery Devices
Figure B2
Figure B3
Figure B4
12
RoHS Compliant, ELV Compliant
203
Page 6
B
F
D E
A
C
B
F
D E
A
C
B
F
D E
A
C
A
B
F
D E
C
B
F
D E
A
C
B
D E
A
C
B
F
D E
A
C
D E
B F
A C
Figure B2-B12 Dimension Figures for Strap Battery Devices
Cont’d
Figure B5
Figure B8
Figure B11
Figure B6
Figure B9
Figure B12
Figure B7
Figure B10
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
Part Number 85°C Typical Activation VLR
VLR170F 20.8 23.2 3.5 3.9 — 0.8 4.5 6.5 4.5 6.5 2.4 2.6 B3
12
204
VLR170LF 38.8 41.2 3.5 3.9 — 0.8 8.7 10.3 18.7 20.3 2.4 2.6 B3
VLR170UF 20.8 23.2 3.5 3.7 — 0.07 5.3 6.7 5.3 6.7 2.4 2.6 B5
VLR175F 23.0 24.5 2.9 3.3 0.5 0.8 4.7 7.2 3.8 5.4 2.4 2.6 B3
VLR175LF 29.3 31.7 2.9 3.3 — 0.8 5.2 6.8 10 12.5 2.4 2.6 B3
VLR175UF 23.0 24.5 2.9 3.1 — 0.7 5.2 7.5 4.3 5.7 2.4 2.6 B5
VLR230F 20.9 23.1 4.9 5.3 — 0.8 4.1 5.8 4.1 5.8 3.9 4.1 B3
RoHS Compliant, ELV Compliant
A
Min. Max. Figure
B
Min. Max.
C
Min. Max.
D
Min. Max.
E
Min. Max.
F
Min. Max.
(0.832) (0.928) (0.140) (0.156) — (0.032) (0.180) (0.260) (0.180) (0.260) (0.096) (0.104)
(1.552) (1.648) (0.140) (0.156) — (0.032) (0.348) (0.412) (0.748) (0.812) (0.096) (0.104)
(0.832) (0.928) (0.140) (0.148) — (0.003) (0.212) (0.268) (0.212) (0.268) (0.096) (0.104)
(0.920) (0.980) (0.116) (0.132) (0.020) (0.032) (0.188) (0.288) (0.152) (0.216) (0.096) (0.104)
(1.172) (1.268) (0.116) (0.132) — (0.032) (0.208) (0.272) (0.400) (0.500) (0.096) (0.104)
(0.920) (0.980) (0.116) (0.124) — (0.028) (0.208) (0.300) (0.172) (0.228) (0.096) (0.104)
(0.836) (0.924) (0.196) (0.212) — (0.032) (0.164) (0.232) (0.164) (0.232) (0.156) (0.164)
Page 7
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
PolySwitch Resettable Devices – Strap Battery Devices
Cont’d
Part Number 90°C Typical Activation VLP
VLP120UF 10.9 11.8 4.4 4.6 — 0.7 5.5 6.5 1.65 1.9 2.3 2.5 B5
VLP175UF 19.0 21.0 3.4 3.6 — 0.7 10.0 11.0 2.5 3.5 2.9 3.1 B5
VLP210F 15.4 17.5 6.9 7.3 0.6 0.8 4.0 6.2 4.0 6.2 3.9 4.1 B2
VLP220F 21.1 23.3 3.5 3.9 0.6 0.8 5.1 6.8 5.1 6.8 2.9 3.1 B3
VLP270F 20.9 23.1 4.9 5.3 0.6 0.8 4.1 5.8 4.1 5.8 3.9 4.1 B3
VTP
VTP110F 23.6 25.6 2.7 2.9 — 0.7 7.0 8.0 7.0 8.0 2.3 2.5 B5
VTP170F 15.4 17.5 7.0 7.4 0.5 0.8 4.0 6.2 4.0 6.2 3.9 4.1 B2
VTP170SSF 15.4 17.5 7.0 7.4 0.5 0.8 4.0 6.2 4.0 6.2 3.9 4.1 B7
VTP170XF 20.9 22.9 4.9 5.3 0.5 0.8 6.0 8.6 6.0 8.6 3.9 4.1 B3
VTP170XSF 20.9 22.9 4.9 5.3 0.5 0.8 6.0 8.6 6.0 8.6 3.9 4.1 B4
VTP175F 21.2 23.2 3.5 3.9 — 0.8 4.6 6.6 4.6 6.6 2.9 3.1 B3
VTP175LF 25.8 28.2 3.5 3.9 — 0.8 5.7 7.3 8.7 10.3 2.4 2.6 B3
VTP210GF 20.9 23.1 4.9 5.3 — 0.8 4.1 5.8 4.1 5.8 3.9 4.1 B3
VTP210SF 20.9 23.1 4.9 5.3 0.6 0.8 4.1 5.8 4.1 5.8 3.9 4.1 B4
120°C Typical Activation MXP
MXP190BB 9.2 10.8 2.96 3.26 0.7 1.1 1.6 3.1 1.6 3.1 2.2 2.4 B12
MXP370BD 10.5 11.3 2.96 3.26 0.7 1.1 5.0 — 2.0 — 2.2 2.4 B12
125°C Typical Activation SRP
SRP120F 19.9 22.1 4.9 5.2 0.6 1.0 5.5 7.5 5.5 7.5 3.9 4.1 B6
SRP120LF 24.9 27.1 4.9 5.2 0.6 1.0 5.5 7.5 10.5 12.5 3.9 4.1 B6
SRP120SF 19.9 22.1 4.9 5.2 0.6 1.0 5.5 7.5 5.5 7.5 3.9 4.1 B10
SRP175F 20.9 23.1 4.9 5.2 0.6 1.0 4.1 5.5 4.1 5.5 3.9 4.1 B6
SRP175LF 29.9 32.1 4.9 5.2 0.6 1.0 10.5 12.5 5.5 7.5 3.9 4.1 B6
SRP175SF 20.9 23.1 4.9 5.2 0.6 1.0 4.1 5.5 4.1 5.5 3.9 4.1 B10
SRP200F 21.3 23.4 10.2 11.0 0.5 1.1 5.0 7.6 5.0 7.6 4.8 5.4 B6
SRP350F 28.4 31.8 13.0 13.5 0.5 1.1 6.3 8.9 6.3 8.9 6.0 6.6 B6
SRP420F 30.6 32.4 12.9 13.6 0.5 1.1 5.0 7.5 5.0 7.5 6.0 6.7 B6
A
Min. Max. Figure
(0.430) (0.460) (0.170) (0.180) — (0.028) (0.220) (0.260) (0.065) (0.075) (0.091) (0.098)
(0.750) (0.830) (0.130) (0.140) — (0.030) (0.390) (0.430) (0.100) (0.140) (0.110) (0.120)
(0.616) (0.700) (0.276) (0.292) (0.024) (0.032) (0.160) (0.248) (0.160) (0.248) (0.156) (0.164)
(0.844) (0.932) (0.140) (0.156) (0.024) (0.032) (0.204) (0.272) (0.204) (0.272) (0.116) (0.124)
(0.836) (0.924) (0.196) (0.212) (0.024) (0.032) (0.164) (0.232) (0.164) (0.232) (0.156) (0.164)
(0.944) (1.024) (0.108) (0.116) — (0.028) (0.280) (0.320) (0.280) (0.320) (0.092) (0.100)
(0.616) (0.700) (0.280) (0.296) (0.020) (0.032) (0.160) (0.248) (0.160) (0.248) (0.156) (0.164)
(0.616) (0.700) (0.280) (0.296) (0.020) (0.032) (0.160) (0.248) (0.160) (0.248) (0.156) (0.164)
(0.836) (0.916) (0.196) (0.212) (0.020) (0.032) (0.240) (0.344) (0.240) (0.344) (0.156) (0.164)
(0.836) (0.916) (0.196) (0.212) (0.020) (0.032) (0.240) (0.344) (0.240) (0.344) (0.156) (0.164)
(0.848) (0.928) (0.140) (0.156) — (0.032) (0.184) (0.264) (0.184) (0.264) (0.116) (0.124)
(1.032) (1.128) (0.140) (0.156) — (0.032) (0.228) (0.292) (0.348) (0.412) (0.096) (0.104)
(0.836) (0.924) (0.196) (0.212) — (0.032) (0.164) (0.232) (0.164) (0.232) (0.156) (0.164)
(0.836) (0.924) (0.196) (0.212) (0.024) (0.032) (0.164) (0.232) (0.164) (0.232) (0.156) (0.164)
(0.368) (0.432) (0.118) (0.130) (0.028) (0.044) (0.064) (0.124) (0.064) (0.124) (0.088) (0.096)
(0.420) (0.452) (0.118) (0.130) (0.028) (0.044) (0.200) — (0.080) — (0.088) (0.096)
(0.796) (0.884) (0.196) (0.208) (0.024) (0.040) (0.220) (0.300) (0.220) (0.300) (0.156) (0.164)
(0.996) (1.084) (0.196) (0.208) (0.024) (0.040) (0.220) (0.300) (0.420) (0.500) (0.156) (0.164)
(0.796) (0.884) (0.196) (0.208) (0.024) (0.040) (0.220) (0.300) (0.220) (0.300) (0.156) (0.164)
(0.836) (0.924) (0.196) (0.208) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.156) (0.164)
(1.196) (1.284) (0.196) (0.208) (0.024) (0.040) (0.420) (0.500) (0.220) (0.300) (0.156) (0.164)
(0.836) (0.924) (0.196) (0.208) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.156) (0.164)
(0.852) (0.936) (0.408) (0.440) (0.020) (0.044) (0.200) (0.304) (0.200) (0.304) (0.192) (0.216)
(1.136) (1.272) (0.520) (0.540) (0.020) (0.044) (0.252) (0.356) (0.252) (0.356) (0.240) (0.264)
(1.224) (1.296) (0.516) (0.544) (0.020) (0.044) (0.200) (0.300) (0.200) (0.300) (0.240) (0.268)
B
Min. Max.
C
Min. Max.
D
Min. Max.
E
Min. Max.
F
Min. Max.
12
RoHS Compliant, ELV Compliant
205
Page 8
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.001 1 10 100
A
A
B
C
B
C
Cont’d
Part Number
A
Min. Max. Figure
B
Min. Max.
C
Min. Max.
D
Min. Max.
E
Min. Max.
F
Min. Max.
LR4
LR4-190F 19.9 22.1 4.9 5.5 0.6 1.0 5.5 7.5 5.5 7.5 3.9 4.1 B8
(0.796) (0.884) (0.196) (0.220) (0.024) (0.040) (0.220) (0.300) (0.220) (0.300) (0.156) (0.164)
LR4-260F 20.9 23.1 4.9 5.5 0.6 1.0 4.1 5.5 4.1 5.5 3.9 4.1 B8
(0.836) (0.924) (0.196) (0.220) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.156) (0.164)
LR4-260SF 20.9 23.1 4.9 5.5 0.6 1.0 4.1 5.5 4.1 5.5 3.9 4.1 B9
(0.836) (0.924) (0.196) (0.220) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.156) (0.164)
LR4-380F 24.0 26.0 6.9 7.5 0.6 1.0 4.1 5.5 4.1 5.5 4.9 5.1 B8
(0.960) (1.040) (0.276) (0.300) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.196) (0.204)
LR4-380XF 32.2 35.8 4.9 5.5 0.6 1.0 5.5 7.5 5.5 7.5 3.9 4.1 B8
(1.288) (1.432) (0.196) (0.220) (0.024) (0.040) (0.220) (0.300) (0.220) (0.300) (0.156) (0.164)
LR4-450F 24.0 26 9.9 10.5 0.6 1.0 5.3 6.7 5.3 6.7 5.9 6.1 B8
(0.960) (1.040) (0.396) (0.420) (0.024) (0.040) (0.212) (0.268) (0.212) (0.268) (0.236) (0.244)
LR4-550F 35.0 37.0 6.9 7.5 0.6 1.0 5.3 6.7 5.3 6.7 4.9 5.1 B8
(1.400) (1.480) (0.276) (0.300) (0.024) (0.040) (0.212) (0.268) (0.212) (0.268) (0.196) (0.204)
LR4-600F 24.0 26.0 13.9 14.5 0.6 1.0 4.1 5.5 4.1 5.5 5.9 6.1 B8
(0.960) (1.040) (0.556) (0.580) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.236) (0.244)
LR4-600XF 40.5 42.7 6.9 7.5 0.6 1.0 5.2 6.8 5.2 6.8 4.9 5.1 B8
(1.620) (1.708) (0.276) (0.300) (0.024) (0.040) (0.208) (0.272) (0.208) (0.272) (0.196) (0.204)
LR4-730F 27.1 29.1 13.9 14.5 0.6 1.0 4.1 5.5 4.1 5.5 5.9 6.1 B8
(1.084) (1.164) (0.556) (0.580) (0.024) (0.040) (0.164) (0.220) (0.164) (0.220) (0.236) (0.244)
LR4-900F 45.4 47.6 7.9 8.5 0.9 1.3 4.6 6.2 4.6 6.2 5.9 6.1 B8
(1.816) (1.904) (0.316) (0.340) (0.036) (0.052) (0.184) (0.248) (0.184) (0.248) (0.236) (0.244)
LR4-1300SSF 61.5 66.5 9.4 10.0 0.9 1.3 5.0 7.5 5.0 7.5 5.9 6.1 B11
(2.460) (2.660) (0.376) (0.400) (0.036) (0.052) (0.200) (0.300) (0.200) (0.300) (0.236) (0.244)
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
VLR (data at 25°C)
A= VLR170F B= VLR175F C= VLR230F
Figure B13
12
206
RoHS Compliant, ELV Compliant
Page 9
Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.001 1 10 100
B
A
B
C
D
C
D A
Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.001
0.0001 1 10 100
A
A
B
C
D
D
E
E
B
C
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
Typical Time-to-trip (s)
Fault Current (A)
10
1
0.10
0.01
0.001 1 10 100
A
B
B
A
PolySwitch Resettable Devices – Strap Battery Devices
Cont’d
VLP (data at 25°C)
A = VLP120UF B = VLP175UF C=VLP210F D=VLP220F E = VLP270F
VTP (data at 25°C)
A= VTP110F B= VTP170F C= VTP175F D= VTP210GF
Figure B14
Figure B15
MXP (data at 25°C)
Figure B16
A= MXP190BB B= MXP370BD
RoHS Compliant, ELV Compliant
12
207
Page 10
Typical Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01 1 10 100
A
A
B
B
C
C
D
D
E
E
Typical Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01 1 10 100
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
Cont’d
SRP
A= SRP120F B= SRP175F C= SRP200F D= SRP350F E= SRP420F
LR4
A= LR4-190F B= LR4-260F C= LR4-380F D= LR4-450F E= LR4-550F F= LR4-600F G= LR4-730F H= LR4-900F I=LR4-1300SSF
Figure B17
Figure B18
Table B5 Physical Characteristics and Environmental Specifications for Strap Battery Devices
VLR
12
208
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5% typical
Humidity aging 60°C/95% RH, 1000 hours ±30% typical Thermal shock 85°C, -40°C (10 times) ±5% typical Vibration MIL-STD-883D, Method 2026 No change
RoHS Compliant, ELV Compliant
60°C, 1000 hours ±20% typical
Page 11
Table B5 Physical Characteristics and Environmental Specifications for Strap Battery Devices
VLP and VTP
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5% typical
60°C, 1000 hours ±10% typical Humidity aging 60°C/95% RH, 1000 hours ±10% typical Thermal shock 85°C, -40°C (10 times) ±5% typical Vibration MIL-STD-883D, Method 2026 No change
MXP
Physical Characteristics
Lead material 0.1mm nominal thickness, half-hard nickel Coating material Epoxy
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5% typical
60°C, 1000 hours ±20% typical
Humidity aging 60°C/95% RH, 1000 hours ±30% typical Thermal shock 85°C, -40°C (10 times) ±5% typical Vibration MIL-STD-883D, Method 2026 No change
PolySwitch Resettable Devices – Strap Battery Devices
Cont’d
SRP
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10% typical Humidity aging 85°C/85% RH, 7 days ±5% typical Vibration MIL-STD-883C,Test Condition A No change
LR4
Physical Characteristics
Lead material 0.125mm nominal thickness, quarter-hard nickel Tape material Polyester
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±10% typical Humidity aging 85°C/85% RH, 7 days ±5% typical Vibration MIL-STD-883D, Method 2026 No change
12
Note:
Storage conditions: 40°C max., 70% RH max.; devices should remain in original sealed bags prior to use. Devices may not meet specified values if these storage conditions are exceeded.
RoHS Compliant, ELV Compliant
209
Page 12
Table B6 Packaging and Marking Information/Agency Recognition for Strap Battery Devices
Part Number
85°C Typical Activation VLR
VLR170F 1,000 — 10,000 R17 UL, CSA,TÜV VLR170LF 1,000 — 10,000 R17 UL, CSA,TÜV VLR170UF 1,000 — 10,000 — UL, CSA,TÜV VLR175F 1,000 — 10,000 R1X UL, CSA,TÜV VLR175LF 1,000 — 10,000 R1X UL, CSA,TÜV VLR175UF 1,000 — 10,000 — UL, CSA,TÜV VLR230F 1,000 — 10,000 R23 UL, CSA,TÜV
90°C Typical Activation VLP
VLP120UF 1,000 — 10,000 — UL, CSA, TÜV VLP175UF 1,000 — 10,000 — UL, CSA, TÜV VLP210F 1,000 — 10,000 W21 UL, CSA, TÜV VLP220F 1,000 — 10,000 W22 UL, CSA, TÜV VLP270F 1,000 — 10,000 W27 UL, CSA, TÜV
VTP
VTP110F 1,000 — 10,000 — UL, CSA, TÜV VTP170F 1,000 — 10,000 V17 UL, CSA, TÜV VTP170SSF 1,000 — 10,000 V17 UL, CSA, TÜV VTP170XF 1,000 — 10,000 V17 UL, CSA, TÜV VTP170XSF 1,000 — 10,000 V17 UL, CSA, TÜV VTP175F 1,000 — 10,000 V1X UL, CSA,TÜV VTP175LF 1,000 — 10,000 V1X UL, CSA, TÜV VTP210GF 1,000 — 10,000 V21 UL, CSA,TÜV VTP210SF 1,000 — 10,000 V21 UL, CSA, TÜV
120°C Typical Activation MXP
MXP190BB 4,000 — 8,000 — UL, CSA,TÜV MXP370BD 2,000 — 4,000 — UL, CSA, TÜV
125°C Typical Activation SRP
SRP120F 1,000 — 10,000 120 UL, CSA, TÜV SRP120LF 1,000 — 10,000 120 UL, CSA,TÜV SRP120SF 2,000 — 10,000 120 UL, CSA, TÜV SRP175F 2,000 — 10,000 175 UL, CSA, TÜV SRP175LF 1,000 — 10,000 175 UL, CSA,TÜV SRP175SF 2,000 — 10,000 175 UL, CSA, TÜV SRP200F 1,000 — 10,000 200 UL, CSA, TÜV SRP350F 500 — 10,000 350 UL, CSA, TÜV SRP420F 500 — 10,000 420 UL, CSA, TÜV
Bag
Quantity
Tape & Reel
Quantity
Standard Package
Quantity Part Marking Agency Recognition
12
210
LR4
LR4-190F 2,000 — 10,000 E19 UL, CSA, TÜV LR4-260F 1,000 — 10,000 E26 UL, CSA, TÜV LR4-260SF 1,000 — 10,000 E26 UL, CSA, TÜV LR4-380F 1,000 — 10,000 E38 UL, CSA, TÜV LR4-380XF 1,000 — 10,000 E38 UL, CSA, TÜV LR4-450F 1,000 — 10,000 E45 UL, CSA, TÜV LR4-550F 1,000 — 10,000 E55 UL, CSA, TÜV LR4-600F 1,000 — 10,000 E60 UL, CSA, TÜV LR4-600XF 1,000 — 10,000 E60 UL, CSA, TÜV LR4-730F 1,000 — 10,000 E73 UL, CSA, TÜV LR4-900F 500 — 10,000 E90 UL, CSA, TÜV LR4-1300SSF 250 — 10,000 EX3 UL, CSA, TÜV
RoHS Compliant, ELV Compliant
Page 13
Agency Recognition for Strap Battery Devices
VTP 210 SF
Modifier
B, BB = Modified resistance window D = Short leaded strap F = Lead-free version G = Global design (standard product) L = Long lead or leads S = Slit lead SS = Both leads slit U = Untaped X = Rotated chip
Hold Current Indicator
Product Series
UL File # E74889 CSA File # 78165C TÜV Certificate number available on request
Installation Guidelines for the Strap Family
• PPTC devices operate by thermal expansion of the conductive polymer. If devices are placed under pressure or installed in spaces that would prevent thermal expansion, they may not properly protect against damage caused by fault conditions. Designs must be selected in such a manner that adequate space is maintained over the life of the product.
• Twisting, bending, or placing the PPTC device in tension will decrease the ability of the device to protect against damage caused by electrical faults. No residual force should remain on device after installation. Mechanical damage to the PPTC device may affect device performance and should be avoided.
• Chemical contamination of PPTC devices should be avoided. Certain greases, solvents, hydraulic fluids, fuels, industrial cleaning agents, volatile components of adhesives, silicones, and electrolytes can have an adverse effect on device performance.
• PPTC strap devices are designed to be resistance welded to battery cells or to pack interconnect straps, yet some precautions must be taken when doing so. In order for the PPTC device to exhibit its specified performance, weld placement should be a minimum of 2mm from the edge of the PPTC device, weld splatter must not touch the PPTC device, and welding conditions must not heat the PPTC device above its maximum operating temperature.
• PPTC strap devices are not designed for applications where reflow onto flex circuits or rigid circuit boards is required.
• The polyester tape on PPTC strap devices is intended for marking and identification purposes only, not for electrical insulation.
• The coating on MXP devices is intended to prevent oxidization/aging of the devices. Damaging the coating or causing the coating to delaminate can have negative effects on device performance and should be avoided.
• MXP devices have small PPTC chip size and therefore have weaker peel strength between polymer and Ni-foil of the chip. Excessive mechanical force to the device may cause delamination of Ni-foil from polymer.
PolySwitch Resettable Devices – Strap Battery Devices
Part Numbering System for Strap Battery Devices
Warning :
• Users should independently evaluate the suitability of and test each product selected for their own application.
• Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
• These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated.
•
Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices.
• Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and mechanical procedures for electronic components.
• PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
• Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.
RoHS Compliant, ELV Compliant