Rev. 10/24/00
SPX2931
ABSOLUTE MAXIMUM RATINGS
Power Dissipation...........................................Internally limited
Lead Temp. (soldering, 5 Seconds)................................. 260°C
Storage Temperature Range........................... -65°C to +150°C
Operating Junction Temperature Range ........... -40°C to +85°C
Input Supply Voltage.............................................-0.3 to +26V
ESD Rating.........................................................................2KV
ELECTRICAL CHARACTERISTICS
at V
S
= 14V, T
A
= 25°C, IO = 10 mA, C2 = 100 µF, unless otherwise specified.
( Note 1)
Parameter Conditions SPX2931A SPX2931 Units
Min Typ Max Min
Typ Max
3.0 Volt Version
SPX2931A-3 SPX2931-3
Output Voltage
6V<V
IN
< 26V,
I
O
= 100 mA Over Temp.
2.94
2.88
3.00
3.00
3.06
3.12
2.91
2.85
3.00
3.00
3.09
3.15
V
V
3.3 Volt Version
SPX2931A-3.3 SPX2931-3.3
Output Voltage
6V < V
IN
< 26V,
I
O
= 100 mA Over Temp.
3.23
3.20
3.30
3.30
3.36
3.39
3.20
3.16
3.30
3.30
3.39
3.43
V
V
5 Volt Version
SPX2931A-5 SPX2931-5
Output Voltage
6V <V
IN
< 26V,
I
O
=100 mA Over Temp.
4.81
4.75
5.00 5.19
5.25
4.75
4.5
5.00 5.25
5.5
V
V
All Voltage Options
Long Term Stability 20 20 mV/1000
Line Regulation 9V < V
IN
< 16V
6V < V
IN
< 26V,
2.0
4.0
10
30
4.0 30 mV
Load Regulation 5 mA < IO < 100 mA 14 50 14 50 mV
Dropout Voltage
IO=10 mA
I
O
=50 mA
I
O
=100 mA
0.05
0.07
0.3
0.2
0.1
0.6
0.05
0.07
0.3
0.2
0.1
0.6
V
V
V
Quiescent Current
IO < 10 mA, 6V < V
IN
< 26V
-40°C < Tj < 85°C
I
O
= 100 mA, V
IN
= 14V,
T
J
= 25°C
0.4
15
1.0 0.4
15
1.0
mA
mA
Maximum Operational Input
Voltage
26 33 26 33 V
Maximum Line Transient
R
L
= 500Ω, VO<5.5V, 100ms
60 70 50 70 V
Reverse Polarity Input
Voltage, DC
V
O
> -0.3V, RL = 500Ω
-15 -30 -15 30 V
Reverse Polarity Input
Voltage, Transient
1% Duty Cycle, τ < 100ms,
R
L
= 500Ω
-50 -80 -50 -80 V
Output Noise Voltage
10Hz-100kHz, C
OUT
=100µF
500 500
µ
Vrms
Ripple Rejection FO = 120Hz 80 80 dB
Note 1:
See
TYPICAL APPLICATIONS
notes to ensure constant junction temperature, low duty cycle pulse testing used.
Note 2:
All limits are at 25°C or over the full operating temperature junction range of -40°C to +85°C.
Note 3:
The maximum power dissipation is a function of maximum junction temperature, total thermal resistance, and ambient temperature.
Note 4:
Human body model, 100 µF discharged through 1.5 KΩ.