Datasheet spp24n60cfd_rev1.3 Datasheet

Page 1
SPP24N60CFD
CoolMOSTMPower Transistor
Features
• Intrinsic fast-recovery body diode
• Extremely low reverse recovery charge
Product Summary
VDS@ Tjmax 650 V R I
• Ultra low gate charge
• High peak current capability
• Qualified for industrial grade applications according to JEDEC
• CoolMOS CFD designed for
• Softswitching PWM Stages
• LCD & CRT TV
Type Package Marking
Type Package Marking
SPP24N60CFD TO-220 24N60CFD
SPP24N60CFD PG-TO220 24N60CFD
Maximum ratings, at Tj=25 °C, unless otherwise specified
DS(on),max
D
1)
0.185
PG-TO220
"
21.7 A
Parameter Symbol Conditions Unit
Continuous drain current
I
D
TC=25 °C TC=100 °C
Pulsed drain current
2)
Avalanche energy, single pulse Avalanche energy, repetitive
Avalanche current, repetitive
2),3)
2),3)
Drain source voltage slope dv/dt
Reverse diode dv/dt dv/dt V/ns Maximum diode commutation speed di/dt A/µs Gate source voltage
I
D,pulse
E
AS
E
AR
I
AR
V
GS
TC=25 °C ID=10A, VDD=50 V ID=20A, VDD=50 V
ID=21.7A, VDS=480V, Tj=125°C
IS=21.7A, VDS=480 V, Tj=125°C
static V
AC (f>1 Hz) Power dissipation Operating and storage temperature
P
tot
Tj, T
TC=25 °C
stg
Value
21.7
13.7 55
780 mJ
1
20
80
40
600 ±20 ±30 240
-55 ... 150
A
A
V/ns
W °C
Mounting torque M3 & M3.5 screws 60 Ncm
Rev. 1.3 page 1 2009-12-01
Page 2
SPP24N60CFD
Parameter Symbol Conditions Unit
Values
min. typ. max.
Thermal characteristics
Thermal resistance, junction - case
Thermal resistance, junction ­ambient
Soldering temperature, wave soldering only allowed at leads
R
thJC
R
thJA
T
sold
leaded - - 62
1.6 mm (0.063 in.) from case for 10 s
- - 0.52 K/W
- - 260 °C
Electrical characteristics, at Tj=25 °C, unless otherwise specified
Static characteristics
Drain-source breakdown voltage Avalanche breakdown voltage
Gate threshold voltage
V
(BR)DSSVGS
V
(BR)DSVGS
V
GS(th)
=0 V, ID=250 µA =0 V, ID=21.7 A
VDS=VGS, ID=1.2 mA
600 - - V
- 700 -
3 4 5
Zero gate voltage drain current
Gate-source leakage current
Drain-source on-state resistance
Gate resistance
Transconductance
I
I
R
R
g
DSS
GSS
DS(on)
G
fs
VDS=600 V, VGS=0 V, Tj=25 °C
VDS=600 V, VGS=0 V, Tj=150 °C
VGS=20 V, VDS=0 V
VGS=10 V, ID=15.4 A, Tj=25 °C
VGS=10 V, ID=15.4 A, Tj=150 °C
- 2.5 - µA
- 2600 -
- - 100 nA
- 0.15 0.185
- 0.42 -
f=1 MHz, open drain - 0.8 ­|VDS|>2|ID|R
ID=15.4 A
DS(on)max
,
- 14.0 - S
"
Rev. 1.3 page 2 2009-12-01
Page 3
SPP24N60CFD
Parameter Symbol Conditions Unit
Values
min. typ. max.
Dynamic characteristics
Input capacitance Output capacitance Reverse transfer capacitance
Effective output capacitance, energy
4)
related
Effective output capacitance, time
5)
related Turn-on delay time
Rise time Turn-off delay time Fall time
C C C
C
C
t t t t
iss
oss
rss
o(er)
o(tr)
d(on)
r
d(off)
f
VGS=0 V, VDS=25 V, f=1 MHz
VGS=0 V, VDS=0 V
to 480 V
VDD=400 V, VGS=10 V, ID= 21.7A, RG=6.8 "
- 3160 - pF
- 900 -
- 34 -
- 103 -
- 188 -
- 50 - ns
- 24 -
- 100 -
- 9 -
Gate Charge Characteristics Gate to source charge Gate to drain charge Gate charge total Gate plateau voltage
1)
J-STD20 and JESD22
2)
Pulse width tplimited byT
3)
Repetitive avalanche causes additional power losses that can be calculated asPAV=EAR*f.
4)
C
is a fixed capacitance that gives the same stored energy as C
o(er)
5)
C
is a fixed capacitance that gives the same charging time asC
o(tr)
j,max
Q Q Q V
gs
gd
g
plateau
VDD=480 V, ID=21.7 A, VGS=0 to 10 V
- 15 - nC
- 67 -
- 110 143
- 7.3 - V
while VDSis rising from 0 to 80% V
oss
while VDSis rising from 0 to 80% V
oss
DSS.
DSS.
Rev. 1.3 page 3 2009-12-01
Page 4
SPP24N60CFD
Parameter Symbol Conditions Unit
Values
min. typ. max.
Reverse Diode
Diode continuous forward current Diode pulse current
2)
Diode forward voltage
Reverse recovery time Reverse recovery charge Peak reverse recovery current
I
S
I
S,pulse
V
SD
t
rr
Q I
rrm
TC=25 °C
- - 21.7 A
- - 55
VGS=0 V, IF=IS, Tj=25 °C
- 1.0 1.2 V
- 140 - ns
rr
diF/dt=100 A/µs
VR=480 V, IF=IS,
- 0.9 - µC
- 11 - A
Rev. 1.3 page 4 2009-12-01
Page 5
1 Power dissipation 2 Safe operating area
P
=f(TC) ID=f(VDS); TC=25 °C; D=0
tot
parameter: t
250
2
10
p
limited by on-state resistance
SPP24N60CFD
1 µs
200
1
10
150
[W]
tot
P
[A]
D
I
100
0
10
50
-1
0
0 40 80 120 160
TC[°C]
10
0
10
1
10
VDS[V]
3 Max. transient thermal impedance 4 Typ. output characteristics
ID=f(VDS); Tj=25 °C ID=f(VDS); Tj=25 °C parameter: D=tp/T parameter: V
0
10
50
45
GS
20 V
10 V
10 µs
100 µs
1 ms
DC
10 ms
2
10
3
10
40
0.5
8 V
35
30
[A]
25
D
I
20
15
7 V
6.5 V
10
6 V
5
0
5.5 V
5 V
0 5 10 15 20
VDS[V]
0.1
0.05
0.02
0.01
single pulse
-5
0.2
-4
10
-3
10
-2
10
-1
10
-1
[K/W]
10
thJC
Z
-2
10
10
tp[s]
Rev. 1.3 page 5 2009-12-01
Page 6
SPP24N60CFD
5 Typ. output characteristics 6 Typ. drain-source on-state resistance
ID=f(VDS); Tj=150 °C R parameter: V
[A]
D
I
GS
35
20 V
10 V
30
8 V
25
20
15
10
5
0
0 5 10 15 20
VDS[V]
7 V
6.5 V
6 V
5.5 V
5 V
=f(ID); Tj=150 °C
DS(on)
parameter: V
1.2
1
0.8
[ ]
DS(on)
R
0.6
0.4
0.2 0 5 10 15 20 25
5 V
GS
5.5 V
6 V
ID[A]
6.5 V
7 V
10 V
20 V
7 Drain-source on-state resistance 8 Typ. transfer characteristics
R
=f(Tj); ID=15.4 A; VGS=10 V ID=f(VGS); |VDS|>2|ID|R
DS(on)
0.6
0.5
0.4
[ ]
0.3
DS(on)
R
98 %
0.2
typ
0.1
0
-60 -20 20 60 100 140 180
Tj[°C]
parameter: T
80
60
[A]
40
D
I
20
0
0 2 4 6 8 10 12 14
j
DS(on)max
VGS[V]
25 °C
150 °C
Rev. 1.3 page 6 2009-12-01
Page 7
SPP24N60CFD
9 Typ. gate charge 10 Forward characteristics of reverse diode
VGS=f(Q
gate
parameter: V
10
8
6
[V]
GS
V
4
2
0
0 25 50 75 100 125
); ID=21.7 A pulsed IF=f(VSD)
DD
120 V
480 V
Q
[nC]
gate
parameter: T
2
10
1
10
[A]
F
I
0
10
-1
10
j
150 °C, 98%
25 °C
150 °C
25 °C, 98%
0 0.5 1 1.5 2
VSD[V]
11 Avalanche SOA 12 Avalanche energy
IAR=f(tAR) EAS=f(Tj); ID=10 A; VDD=50 V parameter: T
[A]
AV
I
j(start)
20
800
700
16
600
12
125 °C
25 °C
8
500
[mJ]
400
AS
E
300
200
4
100
0
-3
10
10
10
10
10
10
10
10
4
3
2
1
0
-1
-2
tAR[µs]
0
25 50 75 100 125 150 175 200
Tj[°C]
Rev. 1.3 page 7 2009-12-01
Page 8
13 Drain-source breakdown voltage 14 Typ. capacitances
SPP24N60CFD
V
BR(DSS)
=f(Tj); ID=10 mA C=f(VDS); VGS=0 V; f=1 MHz
700
660
[V]
620
BR(DSS)
V
580
540
-60 -20 20 60 100 140 180
Tj[°C]
4
10
3
10
2
10
C [pF]
1
10
0
10
0 100 200 300 400 500
Ciss
Coss
Crss
VDS[V]
15 Typ. C
E
=f(VDS) Qrr=f(Tj);parameter: ID=21.7 A
oss
[µJ]
oss
E
stored energy 16 Typ. reverse recovery charge
oss
18
15
12
9
6
3
0
0 100 200 300 400 500 600
1.2
1.1
[µC]
1
rr
Q
0.9
0.8
25 50 75 100 125
VDS[V]
Tj[°C]
Rev. 1.3 page 8 2009-12-01
Page 9
17 Typ. reverse recovery charge 18 Typ. reverse recovery charge
Qrr=f(IS); parameter: di/dt=100 A/µs Qrr=f(di/dt); parameter: ID=21.7 A
SPP24N60CFD
1.2
1
125 °C
[µC]
0.8
rr
Q
0.6
0.4 5 9 13 17 21
25 °C
IS[A]
2.4
2
[µC]
1.6
rr
Q
1.2
0.8 100 200 300 400 500 600
125 °C
25 °C
di/d t [A/µs]
Rev. 1.3 page 9 2009-12-01
Page 10
Definition of diode switching characteristics
SPP24N60CFD
Rev. 1.3 page 10 2009-12-01
Page 11
PG-TO-220-3-1; -3-21
SPP24N60CFD
Dimension in mm/ inches
Rev. 1.3 page 11 2009-12-01
Page 12
Published by
Infineon Technologies AG
81726 Munich, Germany
© 2009 Infineon Technologies AG
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of
conditions or characteristics. With respect to any examples or hints given herein, any typical
values stated herein and/or any information regarding the application of the device,
Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind,
including without limitation, warranties of non-infringement of intellectual property rights
of any third party.
Information
For further information on technology, delivery terms and conditions and prices, please
contact the nearest Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements, components may contain dangerous substances. For information
on the types in question, please contact the nearest Infineon Technologies Office.
Infineon Technologies components may be used in life-support devices or systems only with
the express written approval of Infineon Technologies, if a failure of such components can
reasonably be expected to cause the failure of that life-support device or system or to affect
the safety or effectiveness of that device or system. Life support devices or systems are
intended to be implanted in the human body or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user
or other persons may be endangered.
SPP24N60CFD
Rev. 1.3 page 12 2009-12-01
Loading...