Datasheet SPA560 Datasheet (SOLID STATE DEVICES)

Page 1
现货库存、技术资料、百科信息、热点资讯,精彩尽在鼎好!
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638 Phone: (562) 404-7855 * Fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com
DESIGNER’S DATA SHEET
SPA560 __ __ __
└ │ │ │
Voltage/Family J = 600 V
K = 800 V M = 1000 V
Screening 2/ __ = Not Screened
TX = TX Level TXV = TXV Level S = S Level
Lead Bend __ = Straight Leads
UB = Up Bend DB = Down Bend
SPA560 Series
1/
THREE PHASE BRIDGE RECTIFIER ASSEMBLY
Features:
Higher Blocking Voltage Available. Contact Factory.
Average Output Current 22 Amps
Low Reverse Leakage Current
Constructed with Void-free, Hermetically Sealed Discretes
Aluminum Case for Maximum Thermal Conductivity
Small Package Size (0.89 x 0.89 x 0.39”)
TX and TXV & S Level Screening Available
Superior Replacement for Sensitron S455DC, S455FC, &
S455GC
Standard, Fast, & Hyper Fast Versions Available. Contact Factory.
22A / 600-1000V
ULTRA FAST – 70 ns
Maximum Ratings 3/ Symbol Value Units
Peak Inverse Voltage SPA560J
SPA560K
PIV
SPA560M
Average Rectified Output Current
(TC = Case Temperature)
Peak Surge Current
(8.3 ms Pulse, Half Sine Wave, Superimposed on Rated Load)
= 55°C
T
C
TC = 100°C
IO1 I
I
O2
FSM
Operating & Storage Temperature Top & T
Maximum Thermal Resistance, Junction to Case
R
θJC
stg
600 800
1000
22 15
125
-55 to +150
1.25
Volts
Amps
Amps
ºC
ºC/W
Notes: SPA560
1/ For Ordering Information, Price, and Availability Contact Factory.
/ Screened to MIL-PRF-19500.
2
/ Unless Otherwise Specified, All Maximum Ratings/Electrical
3 Characteristics @25ºC.
NOTE: All specifications are subject to change without notification. SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: RA0091A DOC
Page 2
SPA560 Series
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638 Phone: (562) 404-4474 * Fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com
Electrical Characteristic 3/ Symbol Min Typ Max Units
Maximum Forward Voltage Per Leg
= 25°C, pulsed)
(T
A
Reverse Leakage Current
(Rated PIV, T
= 25ºC)
A
Reverse Leakage Current
(Rated PIV, T
= 100ºC)
A
Isolation Resistance
Reverse Recovery Time
(I
= 500 mA, IR = 1 A, IRR = 250 mA TA = 25ºC
F
(Measured on discrete rectifiers prior to assembly)
NOTES:
1/ For Ordering Information, Price, and Availability Contact Factory.
2/ Screened to MIL-PRF-19500.
/ Unless Otherwise Specified, All Maximum Ratings/Electrical Characteristics @25ºC.
3
I
F
I
F
1500V
= 3A
= 9A
V
VF2
I
I
R
trr
F1
R1
R2
ISO
–– ––
1.40
1.75
Volts
–– –– 10
–– –– 250
–– –– 10
–– –– 70
µA
µA
M
ns
SPA560 Package Outline:
(Shown with Straight Leads)
Lead Bend Options:
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.