Datasheet SCN2661AC1A28, SCN2661BA1F28, SCN2661BC1A28, SCN2661BC1F28, SCN2661BC1N28 Datasheet (Philips)

...
Page 1
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1
1994 Apr 27 853-1070 12793

DESCRIPTION

The EPCI serializes parallel data characters received from the microprocessor for transmission. Simultaneously, it can receive serial data and convert it into parallel data characters for input to the microcomputer.
The SCN2661 contains a baud rate generator which can be programmed to either accept an external clock or to generate internal transmit or receive clocks. Sixteen different baud rates can be selected under program control when operating in the internal clock mode. Each version of the EPCI (A, B, C) has a different set of baud rates.

FEATURES

Synchronous operation
5- to 8-bit characters plus paritySingle or double SYN operationInternal or external character synchronizationTransparent or non-transparent modeTransparent mode DLE stuffing (Tx) and detection (Rx)Automatic SYN or DLE-SYN insertion SYN, DLE and DLESYN
stripping
Odd, even, or no parityLocal or remote maintenance loopback modeBaud rate: DC to 1Mbps (1X clock)
Asynchronous operation
5- to 8-bit characters plus parity1, 1-1/2 or 2 stop bits transmittedOdd, even, or no parityParity, overrun and framing error detectionLine break detection and generationFalse start bit detectionAutomatic serial echo mode (echoplex)Local or remote maintenance loopback modeBaud rate: DC to 1Mbps
(1X clock) DC to 62.5kbps (16X clock) DC to 15.625kbps (64X clock)

OTHER FEATURES

Internal or external baud rate clock
3 baud rate sets
16 internal rates for each set
Double-buffered transmitter and receiver

PIN CONFIGURATIONS

D1 D0
V
CC
RxC/BKDET DTR
RTS DSR
RESET BRCLK TxD TxEMT
/DSCHG CTS
DCD TxRDYRxRDY
R/W
A0
CE
A1
TxC
/XSYNC
D7
D6
D5
D4
GND
RxD
D3
D2
DIP
PLCC
INDEX
CORNER
TOP VIEW
NOTE:
Pin Functions the same as 28-pin DIP.
28 27 26 25 24 23 22 21 20 19 18 17 16 15
1 2 3 4 5 6 7 8
9 10 11 12 13 14
26
25
19
1812
11
5
4 1
SD00077
Dynamic character length switching
Full- or half-duplex operation
TTL compatible inputs and outputs
RxC and TxC pins are short-circuit protected
Single +5V power supply
No system clock required

APPLICATIONS

Intelligent terminals
Network processors
Front-end processors
Remote data concentrators
Computer-to-computer links
Serial peripherals
BISYNC adaptors
Page 2
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
2

ORDERING CODE

VCC = +5V +5%
PACKAGES
Commercial
0°C to +70°C
Industrial
-40°C to +85°C
DWG #
28-Pin Ceramic Dual In-Line Package (cerdip) 0.6” Wide
SCN2661BC1F28 SCN2661CC1F28
SCN2661BA1F28 SCN2661CA1F28
0589B
28-Pin Plastic Dual In-Line Package (DIP) 0.6” Wide
SCN2661AC1N28 SCN2661BC1N28
SCN2661CC1N28
Contact Factory SOT117-2
28-Pin Plastic Lead Chip Carrier (PLCC)
SCN2661AC1A28 SCN2661BC1A28 SCN2661CC1A28
Contact Factory SOT261-3

BLOCK DIAGRAM

DATA BUS
D0–D7
RESET
A
0
A
1
R/W
CE
DATA BUS
BUFFER
OPERATION CONTROL
MODE REGISTER 1
BAUD RATE
GENERATOR
AND
CLOCK CONTROL
SNE/DLE CONTROL
SYN 1 REGISTER SYN 2 REGISTER
DLE REGISTER
TRANSMITTER
TRANSMIT DATA
TxD
MODE REGISTER 2
COMMAND REGISTER
STATUS REGISTER
BRCLK
TxC/SYNC
RxC/BKDET
DSR
MODEM
CONTROL
DCD CTS RTS DTR
TxEMT/*
DSCHG
HOLDING REGISTER
TRANSMIT
SHIFT REGISTER
TxRDY*
RECEIVE DATA
RECEIVE
RECEIVER
RxD
RxRDY
*
HOLDING REGISTER
SHIFT REGISTER
NOTES:
* Open–drain output pin.
SD00078

ABSOLUTE MAXIMUM RATINGS

1
SYMBOL
PARAMETER RATING UNIT
T
A
Operating ambient temperature
2
Note 4 °C
T
STG
Storage temperature -65 to +150 °C All voltages with respect to ground
3
-0.5 to +6.0
V
NOTES:
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or at any other condition above those indicated in the operation section of this specification is not implied.
2. For operating at elevated temperatures, the device must be derated based on +150°C maximum function temperature.
3. This product includes circuitry specifically designed for the protection of its internal devices from the damaging effect of excessive static charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying any voltages larger than the rated maxima.
4. Over recommended free-air operating temperature range and supply voltage range unless otherwise specified. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
Page 3
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
3

DC ELECTRICAL CHARACTERISTICS

1, 2, 3
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Min Typ Max
UNIT
Input voltage
V
IL
V
IH
Low High
2.0
0.8
V V
Output voltage
V
OL
V
OH
4
Low High
IOL = 2.2mA
I
OH
= -400µA 2.4
0.4
V V
I
IL
Input leakage current VIN = 0 to 5.5V 10 µA
3-State output leakage current
I
LH
I
LL
Data bus high Data bus low
VO = 4.0V
VO = 0.45V
10
10
µA µA
I
CC
Power supply current 150 mA
NOTES:
1. Over recommended free-air operating temperature range and supply voltage range unless otherwise specified. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
2. All voltages measurements are referenced to ground. All time measurements are at the 50% level for inputs (except t
BRH
and t
BRL
) and at
0.8V and 2.0V for outputs. Input levels swing between 0.4V and 2.4V , with a transition time of ≤ 20ns maximum.
3. Typical values are at +25°C, typical supply voltages and typical processing parameters.
4. INTR
, TxRDY, RxRDY and TxEMT/DSCHG outputs are open-drain.
CAPACITANCE TA = 25°C, V
CC
= 0V
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Min Typ Max
UNIT

Capacitance

C
IN
C
OUT
C
I/O
Input Output Input/Output
f
C
= 1MHz
Unmeasured pins tied to ground
20 20 20
pF pF pF
Page 4
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
4

AC ELECTRICAL CHARACTERISTICS

1, 2, 3
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Min Typ Max
UNIT
Pulse width
t
RES
t
CE
Reset Chip enable
1000
250
ns ns
Setup and hold time
t
AS
t
AH
t
CS
t
CH
t
DS
t
DH
t
RXS
t
RXH
Address setup Address hold R
/W control setup
R
/W control hold Data setup for write Data hold for write RX data setup RX data hold
10 10 10 10
150
10 300 350
ns ns ns ns ns ns ns ns
t
DD
t
DF
7
t
CED
Data delay time for read Data bus floating time for read CE to CE delay
C
L
= 150pF
C
L
= 150pF
600
200 100
ns ns ns
Input clock frequency
f
BRG
f
BRG
f
R/T
6
Baud rate generator (2661A, B) Baud rate generator (2661C) TxC
or RxC
1.0
1.0 dc
4.9152
5.0688
4.9202
5.0738
1.0
MHz MHz MHz
Clock width
t
BRH
5
t
BRH
5
t
BRL
5
t
BRL
5
t
R/TH
t
R/TL
6
Baud rate High (2661A, B) Baud rate High (2661C) Baud rate Low (2661A, B) Baud rate Low (2661C) TxC
or RxC High
TxC
or RxC Low
75 70 75 70
480 480
ns ns ns ns ns ns
t
TXD
t
TCS
TxD delay from falling edge of TxC Skew between TxD changing and falling edge of TxC
output
4
C
L
= 150pF
C
L
= 150pF
0
650 ns
ns
NOTES:
1. Over recommended free-air operating temperature range and supply voltage range unless otherwise specified. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
2. All voltages measurements are referenced to ground. All time measurements are at the 50% level for inputs (except t
BRH
and t
BRL
) and at
0.8V and 2.0V for outputs. Input levels swing between 0.4V and 2.4V , with a transition time of ≤ 20ns maximum.
3. Typical values are at +25°C, typical supply voltages and typical processing parameters.
4. Parameter applies when internal transmitter clock is used.
5. Under test conditions of 5.0688MHz f
BRG
(68661) and 4.9152MHz f
BRG
(68661A, B), t
BRH
and t
BRL
measured at VIH and VIL, respectively.
6. In asynchronous local loopback mode, using 1X clock, the following parameters apply: f
R/T
= 0.83MHz max and t
R/TL
= 700ns min.
7. See AC load conditions.

BLOCK DIAGRAM

The EPCI consists of six major sections. These are the transmitter, receiver, timing, operation control, modern control and SYN/DLE control. These sections communicate with each other via an internal data bus and an internal control bus. The internal data bus interfaces to the microprocessor data bus via a data bus buffer.

Operation Control

This functional block stores configuration and operation commands from the CPU and generates appropriate signals to various internal sections to control the overall device operation. It contains read and write circuits to permit communications with the microprocessor via the data bus and contains mode registers 1 and 2, the command register, and the status register. Details of register addressing and protocol are presented in the EPCI programming section of this data sheet.

Timing

The EPCI contains a Baud Rate Generator (BRG) which is programmable to accept external transmit or receive clocks or to divide an external clock to perform data communications. The unit can generate 16 commonly used baud rates, any one of which can be selected for full-duplex operation. See Table 1.

Receiver

The receiver accepts serial data on the RxD pin, converts this serial input to parallel format, checks for bits or characters that are unique to the communication technique and sends an “assembled” character to the CPU.

Transmitter

The transmitter accepts parallel data from the CPU, converts it to a serial bit stream, inserts the appropriate characters or bits (based on
Page 5
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
5
the communication technique) and outputs a composite serial stream of data on the TxD output pin.

Modem Control

The modern control section provides interfacing for three input signals and three output signals used for “handshaking” and status indication between the CPU and a modem.

SYN/DLE Control

This section contains control circuitry and three 8-bit registers storing the SYN1, SYN2, and DLE characters provided by the CPU. These registers are used in the synchronous mode of operation to provide the characters required for synchronization, idle fill and data transparency.
Table 1. Baud Rate Generator Characteristics
68661A (BRCLK = 4.9152MHz)
MR23–20
BAUD RATE
ACTUAL FREQUENCY
16X CLOCK
PERCENT
ERROR
DIVISOR
0000 50 0.8kHz 6144 0001 75 1.2 4096 0010 110 1.7598 –0.01 2793 0011 134.5 2.152 2284 0100 150 2.4 2048 0101 200 3.2 1536 0110 300 4.8 1024 0111 600 9.6 512 1000 1050 16.8329 0.196 292 1001 1200 19.2 256 1010 1800 28.7438 –0.19 171 1011 2000 31.9168 –0.26 154 1100 2400 38.4 128 1101 4800 76.8 64 1110 9600 153.6 32
1111 19200 307.2 16
68661B (BRCLK = 4.9152MHz)
MR23–20
BAUD RATE
ACTUAL FREQUENCY
16X CLOCK
PERCENT
ERROR
DIVISOR
0000 45.5 0.7279kHz 0.005 6752 0001 50 0.8 6144 0010 75 1.2 4096 0011 110 1.7598 –0.01 2793 0100 134.5 2.152 2284 0101 150 2.4 2048 0110 300 4.8 1024 0111 600 9.6 512 1000 1200 19.2 256 1001 1800 28.7438 –0.19 171 1010 2000 31.9168 –0.26 154 1011 2400 38.4 128 1100 4800 76.8 64 1101 9600 153.6 32 1110 19200 307.2 16
1111 38400 614.4 8
Page 6
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
6
68661C (BRCLK = 5.0688MHz)
MR23–20
BAUD RATE ACTUAL FREQUENCY 16X CLOCK PERCENT ERROR DIVISOR
0000 50 0.8kHz 6336 0001 75 1.2 4224 0010 110 1.76 2880 0011 134.5 2.1523 0.016 2355 0100 150 2.4 2112 0101 300 4.8 1056 0110 600 9.6 528 0111 1200 19.2 264 1000 1800 28.8 176 1001 2000 32.081 0.253 158 1010 2400 38.4 132 1011 3600 57.6 88 1100 4800 76.8 66 1101 7200 115.2 44 1110 9600 153.6 33
1111 19200 316.8 3.125 16
NOTE: 16X clock is used in asynchronous mode. In synchronous mode, clock multiplier is 1X and BRG can be used only for TxC.

OPERATION

The functional operation of the 68661 is programmed by a set of control words supplied by the CPU. These control words specify items such as synchronous or asynchronous mode, baud rate, number of bits per character, etc. The programming procedure is described in the EPCI programming section of the data sheet.
After programming, the EPCI is ready to perform the desired communications functions. The receiver performs serial to parallel conversion of data received from a modem or equivalent device. The transmitter converts parallel data received from the CPU to a serial bit stream. These actions are accomplished within the framework specified by the control words.

Receiver

The 68661 is conditioned to receiver data when the DCD input is Low and the RxEN bit in the commands register is true. In the asynchronous mode, the receiver looks for High-to-Low (mark to space) transition of the start bit on the RxD input line. If a transition is detected, the state of the RxD line is sampled again after a delay of one-half of a bit-time. If RxD is now high, the search for a valid start bit is begun again. If RxD is still Low, a valid start bit is assumed and the receiver continues to sample the input line at one bit time intervals until the proper number of data bits, the parity bit, and one stop bit have been assembled. The data are then transferred to the receive data holding register, the RxRDY bit in the status register is set, and the RxRDY
output is asserted. If the character length is less than 8 bits, the High order unused bits in the holding register are set to zero. The parity error, framing error, and overrun error status bits are strobed into the status register on the positive going edge of RxC
corresponding to the received character boundary. If the stop bit is present, the receiver will immediately begin its search for the next start bit. If the stop bit is absent (framing error), the receiver will interpret a space as a start bit if it persists into the next bit timer interval. If a break condition is detected (RxD is Low for the entire character as well as the stop bit), only one character consisting of all zeros (with the FE status bit SR5 set) will be transferred to the holding register. The RxD input must return to a High condition before a search for the next start bit begins.
Pin 25 can be programmed to be a break detect output by appropriate setting of MR27-MR24. If so, a detected break will cause that pin to go High. When RxD returns to mark for one RxC time, pin 25 will go low. Refer to the Break Detection Timing Diagram.
When the EPCI is initialized into the synchronous mode, the receiver first enters the hunt mode on a 0 to 1 transition of RxEN (CR2). In this mode, as data are shifted into the receiver shift register a bit at a time, the contents of the register are compared to the contents of the SYN1 register. If the two are not equal, the next bit is shifted in and the comparison is repeated. When the two registers match, the hunt mode is terminated and character assembly mode begins. If single SYN operation is programmed, the SYN DETECT status bit is set. If double SYN operation is programmed, the first character assembled after SYN1 must be SYN2 in order for the SYN DETECT bit to be set. Otherwise, the EPCI returns to the hunt mode. (Note that the sequence SYN1-SYN1-SYN2 will not achieve synchronization.) When synchronization has been achieved, the EPCI continues to assemble characters and transfer then to the holding register, setting the RxRDY status bit and asserting the RxRDY
output each time a character is transferred. The PE and OE status bits are set as appropriate. Further receipt of the appropriate SYN sequence sets the SYN DETECT status bit. If the SYN stripping mode is commanded, SYN characters are not transferred to the holding register. Note that the SYN characters used to establish initial synchronization are not transferred to the holding register in any case.
External jam synchronization can be achieved via pin 9 by appropriate setting of MR27-MR24. When pin 9 is an XSYNC input, the internal SYN1, SYN1–SYN2, and DLE–SYN1 detection is disabled. Each positive going signal on XSYNC will cause the receiver to establish synchronization on the rising edge of the next RxC pulse. Character assembly will start with the RxD input at this edge. XSYNC may be lowered on the next rising edge of RxD. This external synchronization will cause the SYN DETECT status bit to be set until the status register is read. Refer to XSYNC timing diagram.
Page 7
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
7
Table 2. CPU-Related Signals
PIN NAME PIN NO.
INPUT/
OUTPUT
FUNCTION
RESET 21 I A High on this input performs a master reset on the 68661. This signal asynchronously
terminates any device activity and clears the mode, command and status registers. The device assumes the idle state and remains there until initialized with the appropriate control words.
A0, A1 12,10 I Address lines used to select internal EPCI registers. R/W 13 I Read command when Low, write command when High. CE 11 I Chip enable command. When Low , indicates that control and data lines to the EPCI are
valid and that the operation specified by the R
W, A1 and A0 inputs should be performed.
When High, places the D0–D7 lines in the 3-State condition.
D0–D7 27,28,1,2,5–8 I/O 8-bit, 3-State data bus used to transfer commands, data and status between EPCI and the
CPU. D0 is the least significant bit, D7 the most significant bit.
TxRDY 15 O This output is the complement of status register bit SR0. When Low, it indicates that the
transmit data holding register (THR) is ready to accept a data character from the CPU. It goes High when the data character is loaded. This output is valid only when the transmitter is enabled. It is an open-drain output which can be used as an interrupt to the CPU.
RxRDY 14 O This output is the complement of status register bit SR1. When Low, it indicates that the
receive data holding register (RHR) has a character ready for input to the CPU. It goes High when the RHR is read by the CPU, and also when the receiver is disabled. It is an open-drain output which can be used as an interrupt to the CPU.
TxEMT/DS CHG
18 O This output is the complement of status register bit SR2. When Low, it indicates that the
transmitter has completed serialization of the last character loaded by the CPU, or that a change of state of the DSR
or DCD inputs has occurred. This output goes High when the status register is ready by the CPU, if the TxEMT condition does not exist. Otherwise, the THR must be loaded by the CPU for this line to go high. It is an open-drain output which can be used as an interrupt to the CPU. See Status Register (SR2) for details.
Table 3. Device-Related Signals
PIN NAME PIN NO.
INPUT/
OUTPUT
FUNCTION
BRCLK 20 I Clock input to the internal baud rate generator (see Table 1). Not required if external
receiver and transmitter clocks are used.
RxC/BKDET 25 I/O Receiver clock. If external receiver clock is programmed, this input controls the rate at
which the character is to be received. Its frequency is 1X, 16X or 64X the baud rate, as programmed by mode register 1. Data are sampled on the rising edge of the clock. If internal receiver clock is programmed, this pin can be a 1X/16X clock or a break detect output pin.
TxC/XSYNC 9 I/O Transmitter clock. If external transmitter clock is programmed, this input controls the rate at
which the character is transmitted. Its frequency is 1X, 16X or 64X the baud rate, as programmed by mode register 1. The transmitted data changes on the falling edge of the clock. If internal transmitter clock is programmed, this pin can be a 1X/16X clock output or an external jam synchronization input.
RxD 3 I Serial data input to the receiver. “Mark” is High, “space” is Low. TxD 19 O Serial data output from the transmitter. “Mark” is High, “Space” is Low. Held in mark
condition when the transmitter is disabled.
DSR 22 I General purpose input which can be used for data set ready or ring indicator condition. Its
complement appears as status register bit SR7. Causes a Low output on TxEMT
/DSCHG
when its state changes if CR2 or CR0 = 1.
DCD 16 I Data carrier detect input. Must be Low in order for the receiver to operate. Its complement
appears as status register bit SR6. Causes a Low output on TxEMT
/DSCHG when its state changes if CR2 or CR0 = 1. If DCD goes High while receiving, the RxC is internally inhibited.
CTS 17 I Clear to send input. Must be Low in order for the transmitter to operate. If it goes High
during transmission, the character in the transmit shift register will be transmitted before termination.
DTR 24 O General purpose output which is the complement of command register bit CR1. Normally
used to indicate data terminal ready.
RTS 23 O General purpose output which is the complement of command register bit CR5. Normally
used to indicate request to send. See Command Register (CR5) for details.
Page 8
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
8

Transmitter

The EPCI is conditioned to transmit data when the CTS input is Low and the TxEN command register bit is set. The 68661 indicates to the CPU that it can accept a character for transmission by setting the TxRDY status bit and asserting the TxRDY
output. When the CPU writes a character into the transmit data holding register, these conditions are negated. Data are transferred from the holding register to the transmit shift register when it is idle or has completed transmission of the previous character. The TxRDY conditions are then asserted again. Thus, one full character time of buffering is provided.
In the asynchronous mode, the transmitter automatically sends a start bit followed by the programmed number of data bits, the least significant bit being sent first. It then appends an optional odd or even parity bit and the programmed number of stop bits. If, following transmission of the data bits, a new character is not available in the transmit holding register, the TxD output remains in the marking (High) condition and the TxEMT
/DSCHG output and its corresponding status bit are asserted. Transmission resumes when the CPU loads a new character into the holding register. The transmitter can be forced to output a continuous Low (BREAK) condition by setting the send break command bit (CR3) High.
In the synchronous mode, when the 68661 is initially conditioned to transmit, the TxD output remains High and the TxRDY condition is asserted until the first character to be transmitted (usually a SYN character) is loaded by the CPU. Subsequent to this, a continuous stream of characters is transmitted. No extra bits (other than parity, if commanded) are generated by the EPCI unless the CPU fails to send a new character to the EPCI by the time the transmitter has completed sending the previous character. Since synchronous communication does not allow gaps between characters, the EPCI asserts TxEMT and automatically “fills” the gap by transmitting SYN1s, SYN1–SYN2 doublets, or DLE–SYN1 doubles, depending on the state of MR16 and MR17. Normal transmission of the message resumes when a new character is available in the transmit data holding register. If the send DLE bit in the commands register is true, the DLE character is automatically transmitted prior to transmission of the message character in the THR.

EPCI PROGRAMMING

Prior to initiating data communications, the 68661 operational mode must be programmed by performing write operations to the mode and command registers. In addition, if synchronous operation is programmed, the appropriate SYN/DLE registers must be loaded. The EPCI can be reconfigured at any time during program execution. A flowchart of the initialization process appears in Figure 1.
The internal registers of the EPCI are accessed by applying specific signals to the CE
, R/W, A1 and A0 inputs. The conditions
necessary to address each register are shown in Table 4. The SYN1, SYN2, and DLE registers are accessed by performing
write operations with the conditions A1 = 0, A0 = 1, and R
/W = 1. The first operation loads the SYN1 register. The next loads the DLE register. Reading or loading the mode registers is done in a similar manner. The first write (or read) operation addresses mode register
1, and a subsequent operation addresses mode register 2. If more than the required number of accesses are made, the internal sequencer recycles to point at the first register. The pointers are reset to SYN1 register and mode register 1 by a RESET input or by performing a read command register operation, but are unaffected by any other read or write operation.
The 68661 register formats are summarized in Tables 5, 6, 7 and 8. Mode registers 1 and 2 define the general operational characteristics of the EPCI, while the command register controls the operation within this basic framework. The EPCI indicates its status in the status register. These registers are cleared when a RESET input is applied.

Mode Register 1 (MR1)

Table 5 illustrates mode register 1. Bits MR11 and MR10 select the communication format and baud rate multiplier. 00 specifies synchronous format. However, the multiplier in asynchronous format applies only if the external clock input option is selected by MR24 or MR25.
MR13 and MR12 select a character length of 5, 6, 7 or 8 bits. The character length does not include the parity bit, if programmed, and does not include the start and stop bits in asynchronous mode.
MR14 controls parity generation. If enabled, a parity bit is added to the transmitted character and the receiver performs a parity check on incoming data. MR15 selects odd or even parity when parity is enabled by MR14. In asynchronous mode, MR17 and MR16 select character framing of 1, 1.5, or 2 stop bits. (If 2X baud rate is programmed, 1.5 stop bits defaults to 1 stop bits on transmit.) In synchronous mode, MR17 controls the number of SYN characters used to establish synchronization and for character fill when the transmitter is idle. SYN1 alone is used if MR17 = 1, and SYN1–SYN2 is used when MR17 = 0. If the transparent mode is specified by MR16, DLE–SYN1 is used for character fill and SYN detect, but the normal synchronization sequence is used to establish character sync. When transmitting, a DLE character in the transmit holding register will cause a second DLE character to be transmitted. This DLE stuffing eliminates the software DLE compare and stuff on each transparent mode data character. If the send DLE command (CR3) is active when a DLE is loaded into THR, only one additional DLE will be transmitted. Also, DLE stripping and DLE detect (with MR14 = 0) are enabled.
The bits in the mode register affecting character assembly and disassembly (MR12–MR16) can be changed dynamically (during active receive/transmit operation). The character mode register affects both the transmitter and receiver; therefore in synchronous mode, changes should be made only in half-duplex mode (RxEN = 1 or TxEN = 1, but not both simultaneously = 1). In asynchronous mode, character changes should be made when RxEN and TxEN = 0 or when TxEN = 1 and the transmitter is marking in half-duplex mode (RxEN = 0).
To effect assembly/disassembly of the next received/transmitted character, MR12 – 15 must be changed within n bit times of the active going state of RxRDY
/TxRDY. Transparent and non-transparent mode changes (MR16) must occur within n-1 bit times of the character to be affected when the receiver or transmitter is active. (n – smaller of the new and old character lengths.)
Page 9
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
9
Table 4. 68661 Register Addressing
CE A
1
A
0
R/W FUNCTION
1 0 0 0 0 0 0 0 0
X
0 0 0 0 1 1 1 1
X 0 0 1 1 0 0 1 1
X
0 1 0 1 0 1 0 1
3-State data bus Read receive holding register Write transmit holding register Read status register Write SYN1/SYN2/DLE registers Read mode register 1/2 Write mode register 1/2 Read command register Write command register
LOAD
MODE REGISTER 1
LOAD
MODE REGISTER 2
SYNCHRONOUS?
LOAD
SYN 1 REGISTER
DOUBLE
SYNC?
LOAD
SYN 2 REGISTER
TRANSPARENT
MODE?
LOAD
DLE REGISTER
INITIAL RESET
N
Y
Y
N
N
Y
TRANSPARENT
MODE?
Y
N
LOAD
COMMAND REGISTER
OPERATE
RECONFIGURE?
N
Y
DISABLE
RCVR AND XMTR
NOTE:
SYN1 Register must be written before SYN2 can be written, and SYN2 before DLE can be written.
NOTE:
Mode Register 1 must be written before 2 can be written. Mode Register 2 need not be programmed if external clocks are used.
SD00079
Figure 1. 68661 Initialization Flowchart
Page 10
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
10
Table 5. Mode Register 1 (MR1)
MR17 MR16 MR15 MR14 MR13 MR12 MR11 MR10
Sync/Async Parity Type Parity Control Character Length Mode and Baud Rate Factor
Async: Stop bit length
00 = invalid 01 = 1 stop bit 10 = 1 1/2 stop bits 11 = 2 stop bits
0 = Odd 1 = Even
0 = Disabled 1 = Enabled
00 = 5 bits 01 = 6 bits 10 = 7 bits 11 = 8 bits
00 = Synchronous 1X rate 01 = Asynchronous 1X rate 10 = Asynchronous 16X rate 11 = Asynchronous 64X rate
Sync: Number of SYN char
0 = Double SYN 1 = Single SYN
Sync: Transparency control
0 = Normal 1 = Transparent
NOTE: Baud rate factor in asynchronous applies only if external clock is selected. Factor is 16X if internal clock is selected. Mode must be
selected (MR11, MR10) in any case.
Table 6. Mode Register 2 (MR2)
MR27 – MR24 MR23 – MR20
TxC RxC Pin 9 Pin 25 TxC RxC Pin 9 Pin 25 Mode
Baud Rate
Selection
0000 0001 0010 0011 0100 0101 0110 0111
E E
I
I E E
I
I
E
I
E
I
E
I
E
I
TxC TxC
1X
1X TxC TxC 16X 16X
RxC
1X
RxC
1X
RxC
16X
RxC
16X
1000 1001 1010 1011 1100 1101 1110
1111
E E
I
I E E
I
I
E
I
E
I
E
I
E
I
XSYNC*
TxC
XSYNC*
1X
XSYNC*
TXC
XSYNC*
16X
RXC/TxC
BKDET
RxC
BKDET
RxC/TxC
BKDET
RxC
BKDET
sync
async
sync
async
sync
async
sync
async
See baud rates
in Table 1.
NOTES:
* When pin 9 is programmed as XSYNC input, SYN1, SYN1–SYN2, and DLE–SYN1 detection is disabled. E = External clock I = Internal clock (BRG) 1X and 16X are clock outputs.
Table 7. Command Register (CR)
CR7 CR6 CR5 CR4 CR3 CR2 CR1 CR0
Operating Mode
Request
to Send
Reset Error Sync/Async
Receive
Control
(RxEN)
Data Terminal
Ready
Transmit
Control
(TxEN)
00 = Normal operation 01 = Async:
Automatic Echo mode Sync: SYN and/or DLE
stripping mode 10 = Local loopback 11 = Remote loopback
0 = Force RTS
Output High one clock time after TxSR serialization
1 = Force RTS
output Low
0 = Normal 1 = Reset error
flags in status reg. (FE,OE,PE/ DLE detect.)
Async:
Force Break 0 = Normal 1 = Force break
Sync Send DLE
0 = Normal 1 = Send DLE
0 = Disable 1 = Enable
Not applicable
in
0 = Force DTR
output High
1 = Force DTR
output Low
0 = Disable 1 = Enable
Page 11
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
11
Table 8. Status Register (SR)
SR7 SR6 SR5 SR4 SR3 SR2 SR1 SR0
Data Set
Ready
Data Carrier
Detect
FE/SYN
Detect
Overrun
PE/DLE
Detect
TxEMT
DSCHG
RxRDY TxRDY
0 = DSR input
is High
1 = DSR
input
is Low
0 = DCD input
is High
1 = DCD
input
is Low
Async:
0 = Normal 1 = Framing
error
Sync:
0 = Normal 1 = SYN
detected
0 = Normal 1 = Overrun
error
Async:
0 = Normal 1 = Parity error
Sync:
0 = Normal 1 = Parity error
or DLE received
0 = Normal 1 = Change in
DSR
or
DCD
, or transmit shift register is empty
0 = Receive
holding register empty
1 = Receive
holding register has data
0 = Transmit
holding register busy
1 = Transmit
holding register empty

Mode Register 2 (MR2)

Table 6 illustrates mode register 2. MR23, MR22, MR21 and MR20 control the frequency of the internal baud rate generator (BRG). Sixteen rates are selectable for each EPCI version (–1,–2,–3). Versions 1 and 2 specify a 4.9152MHz TTL input at BRCLK (pin 20); version 3 specifies a 5.0688MHz input which is identical to the Philips Semiconductors 2651. MR23 – 20 are don’t cares if external clocks are selected (MR25 – MR24 = 0). The individual rates are given in Table 1.
MR24 – MR27 select the receive and transmit clock source (either the BRG or an external input) and the function at pins 9 and 25. Refer to Table 6.

Command Register (CR)

Table 7 illustrates the command register . Bits CR0 (TxEN) and CR2 (RxEN) enable or disable the transmitter and receiver respectively. A 0– to–1 transition of CR2 forces start bit search (async mode) or hunt mode (sync mode) on the second RxC
rising edge. Disabling
the receiver causes RxRDY
to go High (inactive). If the transmitter is disabled, it will complete the transmission of the character in the transmit shift register (if any) prior to terminating operation. The TxD output will then remain in the marking state (High) while TxRDY
and
TxEMT
will go High (inactive). If the receiver is disabled, it will terminate operation immediately. Any character being assembled will be neglected. A 0–to–1 transition of CR2 will initiate start bit search (async) or hunt mode (sync).
Bits CR1 (DTR) and CR5 (RTS) control the DTR
and RTS outputs.
Data at the outputs are the logical complement of the register data. In asynchronous mode, setting CR3 will force and hold the TxD
output Low (spacing condition) at the end of the current transmitted character. Normal operation resumes when CR3 is cleared. The TxD line will go High for at least one bit time before beginning transmission of the next character in the transmit data holding register. In synchronous mode, setting CR3 causes the transmission of the DLE register contents prior to sending the character in the transmit data holding register. Since this is a one time command, CR3 does not have to be reset by software. CR3 should be set when entering and exiting transparent mode and for all DLE-non-DLE character sequences.
Setting CR4 causes the error flags in the status register (SR3, SR4, and SR5) to be cleared; this is a one time command. There is no internal latch for this bit.
When CR5 (RTS) is set, the RTS
pin is forced Low. A 1–to–0
transition of CR5 will cause RTS
to go High (inactive) one TxC time after the last serial bit has been transmitted. If a 1–to–0 transition of CR5 occurs while data is being transmitted, RTS
will remain Low
(active) until both the THR and the transmit shift register are empty and then go High (inactive) one TxC time later.
The EPCI can operate in one of four submodes within each major mode (synchronous or asynchronous). The operational sub-mode is determined by CR7 and CR6. CR7 – CR6 = 00 is the normal mode, with the transmitter and receive operating independently in accordance with the mode and status register instructions.
In asynchronous mode, CR7 – CR6 = 01 places the EPCI in the automatic echo mode. Clocked, regenerated received data are automatically directed to the TxD line while normal receiver operation continues. The receiver must be enabled (CR2 = 1), but the transmitter need not be enabled. CPU to receiver communication continues normally, but the CPU to transmitter link is disabled. Only the first character of a break condition is echoed.
The TxD output will go High until the next valid start is detected. The following conditions are true while in automatic echo mode:
1. Data assembled by the receiver are automatically placed in the transmit holding register and retransmitted by the transmitter on the TxD output.
2. The transmitter is clocked by the receive clock.
3. TxRDY
output = 1.
4. The TxEMT/DSCHG
pin will reflect only the data set change
condition.
5. The TxEN command (CR0) is ignored.
In synchronous mode, CR7 – CR6 = 01 places the EPCI in the automatic SYN/DLE stripping mode. The exact action taken depends on the setting of bits MR17 and MR16:
1. In the non-transparent, single SYN mode (MR17 – MR16 = 10), characters in the data stream matching SYN1 are not transferred to the Receive Data Holding register (RHR).
2. In the non-transparent, double SYN mode (MR17 – MR16 = 00), character in the data stream matching SYN1, or SYN2 if immedi­ately preceded by SYN1, are not transferred the RHR.
3. In transparent mode (MR16 = 1), character in the data stream matching DLE, or SYN1 if immediately preceded by DLE, are not transferred to the RHR. However, only the first DLE of a DLE– DLE pair is stripped.
Note that automatic stripping mode does not affect the setting of the DLE detect and SYN detect status bits (SR3 and SR5).
Two diagnostic sub-modes can also be configured. In local loopback mode (CR7 – CR6 = 10), the following loops are connected internally:
Page 12
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
12
1. The transmitter output is connected to the receiver input.
2. DTR
is connected to DCD and RTS is connected to CTS.
3. The receiver is clocked by the transmit clock.
4. The DTR
, RTS and TxD outputs are held High.
5. The CTS
, DCD, DSR and RxD inputs are ignored.
Additional requirements to operate in the local loopback mode are that CR0 (TxEN), CR1 (DTR) and CR5 (RTS) must be set to 1. CR2 (RxEN) is ignored by the EPCI.
The second diagnostic mode is the remote loopback mode (CR7 – CR6 = 11). In this mode:
1. Data assembled by the receiver are automatically placed in the transmit holding register and retransmitted by the transmitter on the TxD output.
2. The transmitter is clocked by the receiver clock.
3. No data are sent to the local CPU, but he error status conditions (PE, FE) are set.
4. The RxRDY
, TxRDY, and TxEMT/DSCHG outputs are held High.
5. CR0 (TxEN) is ignored.
6. All other signals operate normally.

Status Register

The data contained in the status register (as shown in Table 8) indicates receiver and transmitter conditions and modem/data set status.
SR0 is the transmitter ready (TxRDY) status bit. It, and its corresponding output, are valid only when the transmitter is enabled. If equal to 0–, it indicates that the transmit data holding register has been loaded by the CPU and the data has not been transferred to the transmit register. If set equal to 1, it indicates that the holding register is ready to accept data from the CPU. This bit is initially set when the transmitter is enabled by CR0, unless a character has previously been loaded into the holding register. It is not set when the automatic echo or remote loopback modes are programmed. When this bit is set, the TxRDY
output pin is Low. In the automatic
echo and remote loopback modes, the output is held High. SR1, the receiver ready (RxRDY) status bit, indicates the condition
of the receive data holding register. If set, it indicates that a character has been loaded into the holding register from the receive shift register and is ready to be read by the CPU. If equal to zero,
there is no new character in the holding register. This bit is cleared when the CPU reads the receive data holding register or when the receiver is disabled by CR2. When set, the RxRDY
output is Low.
The TxEMT/DSCHG bit, SR2, when set, indicates either a change of state of the DSR
or DCD inputs (when CR2 or CR0 = 1) or that the transmit shift register has completed transmission of a character and no new character has been loaded into the transmit data holding register. Note that in synchronous mode this bit will be set even though the appropriate “fill” character is transmitted. TxEMT will not go active until at least one character has been transmitted. It is cleared by loading the transmit data holding register. The DSCHG conditions is enabled when TxEN = 1 or RxEN = 1. It is cleared when the status register is read by the CPU. If the status register is read twice and SR2 – 1 while SR6 and SR7 remain unchanged, then a TxEMT condition exists. When SR2 is set, the TxEMT
/DSCHG output is Low.
SR3, when set, indicates a received parity error when parity is enabled by MR14. In synchronous transparent mode (MR16 = 1), with parity disabled, it indicates that a character matching DLE register was received and the present character is neither SYN2 or DLE. This bit is cleared when the next character following the above sequence is loaded into RHR, when the receiver is disabled, or by a reset error command, CR4.
The overrun error status bit, SR4, indicates that the previous character loaded into the receive holding register was not ready the CPU at the time of new received character was transferred into it. This bit is cleared when the receiver is disabled or by the reset error command, CR4.
In asynchronous mode, bit SR5 signifies that the received character was not framed by a stop bit; i.e., only the first stop bit is checked. If RHR = 0 when SR5 = 1, a break condition is present. In synchronous non-transparent mode (MR16 = 0), it indicates receipt of the SYN1 character in single SYN mode or the SYN1 – SYN2 pair in double SYN mode. In synchronous transparent mode (MR16 =
1), this bit is set upon detection of the initial synchronizing characters (SYN or SYN1 – SYN2) and, after synchronization has been achieved, when a DLE–SYN1 pair is received. The bit is reset when the receiver is disabled, when the reset error command is given in asynchronous mode, or when the status register is read by the CPU in the synchronous mode.
SR6 and SR7 reflect the conditions of the DCD
and DSR inputs, respectively. A Low input sets its corresponding status bit, and a High input clears it.
Page 13
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
13
Table 9. 68661 EPCI vs 2651 PCI
FEATURE EPCI PCI
1. MR2 BIT 6, 7 Control pins 9, 25 Not used
2. DLE detect – SR3 SR3 = 0 for DLE–DLE, DLE – SYN1 SR3 = 1 for DLE–DLE, DLE – SYN1
3. Reset of SR3, DLE detect Second character after DLE, or receiver disable, or CR4 = 1
Receiver disable, or CR4 = 1
4. Send DLE – CR3 One time command Reset via CR3 on next TxRDY
5. DLE stuffing in transparent mode Automatic DLE stuffing when DLE is loaded except if CR3 = 1
None
6. SYN1 stripping in double sync
non-transparent mode
All SYN1 First SYN1 of pair
7. Baud rate versions Three One
8. Terminate ASYNC transmission (drop
RTS)
Reset CR5 in response to TxEMT changing from 1 to 0
Reset CR0 when TxEMT goes from 1 to 0. Then reset CR5 when TxEMT
goes from
1 to 0
9. Break detect Pin 25
*
FE and null character
10. Stop bit searched One Two
11. External jam sync Pin 9
**
No
12. Data bus timing Improved over 2651
13. Data bus drivers Sink 2.2mA Source 400µA
Sink 1.6mA Source 100µA
NOTES:
* Internal BRG used for RxC. ** Internal BRG used for TxC.

AC LOAD CONDITIONS

CL = 150pF
NOTES:
Open-drain outputs. C
L
= Load capacitance includes JIG and probe capacitance.
2.2V
OUTPUT
750
CL = 50pF
+5V
OUTPUT
2k
SD00080
Page 14
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
14

TIMING DIAGRAMS

RESET
t
RES
RESET
BRCLK,
TxC
, RxC
1/f
BRG
t
R/TH
t
BRH
t
R/TL
t
BRL
1/f
R/T
CLOCK
TRANSMIT
RECEIVE
TxC
(INPUT)
1 BIT TIME
(1, 16, OR 64 CLOCK PERIODS)
TxD
TxC
(OUTPUT)
t
TxD
t
TCS
t
TxD
RxD
RxC (IX)
t
RXS
t
RXH
t
CE
t
CED
CE
A
0
,
A
1
R/W
t
AS
t
CS
t
AH
t
CH
D0–D
7
(WRITE)
t
DS
t
DH
BUS
FLOATING
NOT
VALID
BUS
FLOATING
DATA VALID
t
DD
t
DF
D0–D
7
(READ)
READ AND WRITE
SD00052
Page 15
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
15
TIMING DIAGRAMS (Continued)
1 2 3 4 5
DATA 1
1 2 3 4 5
DATA 2
1 2 3 4 5
DATA 3
1 2 3 4 5
SYN 1
1 2 3 4 5
DATA 4
1 2 3 4 5
DATA 1
A B C 1 2 3 4 5A B C
DATA 2
1 2 3 4 5A B C
DATA 3
1 2A
DATA 4
D D
DATA 1 DATA 2 DATA 3 DATA 4
DATA 1 DATA 2 DATA 3 DATA 4
TxC
(1X)
TxD
TxEN
TxRDY
TxEMT
CE FOR
WRITE
OF THR
TxD
TxEN
TxRDY
TxEMT
CE FOR
WRITE
OF THR
ASYNCHRONOUS MODE SYNCHRONOUS MODE
TxRDY, TxEMT (Shown for 5-bit characters, no parity, 2 stop bits [in asynchronous mode])
NOTES:
A = Start bit B = Stop bit 1 C = Stop bit 2 D = TxD marking condition TxEMT goes low at the beginning of the last data bit, or, if parity is enabled, at the beginning of the parity bit.
SD00053
Page 16
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
16
TIMING DIAGRAMS (Continued)
SD00081
t
es
t
H
1X RxC
XSYNC
RxD
RxC + 16 OR 64
RxD
X 0 1 2 3 4
CHARACTER ASSEMBLY
EXTERNAL SYNCHRONIZATION WITH XSYNC
t
es
= XSYNC SETUP TIME = 300ns
t
H
= XSYNC HOLD TIME = ONE RxC
BREAK DETECTION TIMING
MISSING STOP BIT
DETECTED SET FE BIT*
1st DATA BIT
SAMPLED
LOOK FOR START BIT = LOW (IF RxD IS HIGH, LOOK FOR HIGH TO LOW TRANSITION)
FALSE START BIT CHECK MADE (RxD LOW)
Rx CHARACTER = 5 BITS, NO PARITY
MISSING STOP BIT DETECTED, SET FE BIT. 0 RHR, ACTIVATE RxRDY. SET BKDET PIN RxD INPUT RxSR UNTIL A MARK TO SPACE TRANSITION OCCURS.
NOTE:
* If the stop bit is present, the start bit search will commence immediately.
Page 17
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
17
TIMING DIAGRAMS (Continued)
1 2 3 4 5
SYN 1
1 2 3 4 5
DATA 1
1 2 3 4 5
DATA 2
1 2 3 4 5
DATA 3
1 2 3 4 5
DATA 4
1 2 3 4 5
DATA 1
A B C 1 2 3 4 5A B C
DATA 2
1 2 3 4 5A
DATA 3
D
READ RHR
(DATA 1)
READ RHR
(DATA 3)
READ
STATUS
RxC
RxD
RxEN
RxRDY
CE FOR
READ
RxD
RxEN
RxRDY
CE FOR
READ
ASYNCHRONOUS MODE SYNCHRONOUS MODE
RxRDY (Shown for 5-bit characters, no parity, 2 stop bits [in asynchronous mode])
NOTES:
A = Start bit B = Stop bit 1 C = Stop bit 2 D = TxD marking condition
1
2 3 4 5
DATA 5
IGNORED
READ RHR
(DATA 1)
READ RHR
(DATA 2)
READ RHR
(DATA 3)
READ RHR
(DATA 3)
READ
STATUS
SYNDET
STATUS BIT
D
_ _
B C 1 2 3A
DATA 4
OVERRUN
STATUS BIT
SD00054
Page 18
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
18

TYPICAL APPLICATIONS

SD00082
ADDRESS BUS
CONTROL BUS
DATA BUS
8
RxD
TxD
BRCLK
SCN2661/68661
EIA TO TTL
CONVERT
(OPT)
BAUD RATE CLOCK
OSCILLATOR
ASYNCHRONOUS INTERFACE TO CRT TERMINAL
CRT
TERMINAL
ADDRESS BUS
CONTROL BUS
DATA BUS
8
RxD
TxD
SCN2661/68661
ASYNCHRONOUS INTERFACE TO TELEPHONE LINES
DSR
DTR
CTS RTS
DCD
BRCLK
ASYNC
MODEM
BAUD RATE CLOCK
OSCILLATOR
PHONE
LINE
INTERFACE
TELEPHONE
LINE
Page 19
Philips Semiconductors Product specification
SCN2661/SCN68661
Enhanced programmable communications interface (EPCI)
1994 Apr 27
19
TYPICAL APPLICATIONS (Continued)
ADDRESS BUS
CONTROL BUS
DATA BUS
RxD TxD
SCN2661/68661
SYNCHRONOUS
TERMINAL OR
PERIPHERAL
DEVICE
SYNCHRONOUS INTERFACE TO TERMINAL OR PERIPHERAL DEVICE
ADDRESS BUS
CONTROL BUS
DATA BUS
RxD
TxD
SCN2661/68661
SYNCHRONOUS INTERFACE TO TELEPHONE LINES
DCD
RTS
DSR DTR
SYNC
MODEM
PHONE
LINE
INTERFACE
TELEPHONE
LINE
RxC TxC
RxC
TxC
CTS
SD00083
Loading...