© 1998 SEMTECH CORP. 652 MITCHELL ROAD NEWBURY PARK CA 91320
PRECISION SHUNT VOLTAGE
REFERENCE
SC4041
PRELIMINARY - April 13, 1998
3
ELECTRICAL CHARACTERISTICS
TA = 25°C unless otherwise specifi ed.
SC4041A (0.1%) SC4041B (0.2%)
Parameter Symbol Condition MIN TYP MAX MIN TYP MAX UNITS
Reverse Breakdown Voltage
V
ZIZ
= 100µA TA = 25°C 1.2238 1.2250 1.2262 1.2226 1.2250 1.2274 V
TA = -40 to +85°C 1.2158 1.2250 1.2342 1.2146 1.2250 1. 2354 V
Minimum Operating Current
I
Z(min)
30 60 30 60 µA
Reverse Breakdown Voltage Temperature Coefficient
I
Z
= 10mA
I
Z
= 1mA
I
Z
= 100µA
T
A
= -40 to +85°C ±100 ±100 ppm/°C
Ratio of Change in VZ to
Change in I
Z
I
Z(min)
< IZ < 1mA TA = 25°C 1.5 1.5 mV
T
A
= -40 to +85°C 2.0 2.0 mV
1mA <
IZ < 12mA TA = 25°C 6.0 6.0 mV
T
A
= -40 to +85°C 8.0 8.0 mV
Reverse Dynamic
Impedance
Z
RIZ
= 1mA, f = 120 Hz, IAC = 0.1 I
Z
0.25 1.5 0.25 1.5
Ω
Wideband Noise (RMS) e
NIZ
= 100µA
10Hz <
f < 10kHz
20 20 µV
Long Term Stability of Reverse Breakdown Voltage
t = 1000 hours
T = 25°C ± 0.1°C
I
Z
= 100µA
120 120 ppm
T
V
Z
∆
∆
Z
Z
I
V
∆
∆
Z
V
∆
TA = 25°C unless otherwise specifi ed.
SC4041C (0.5%) SC4041D (1.0%)
Parameter Symbol Condition MIN TYP MAX MIN TYP MAX UNITS
Reverse Breakdown Voltage
V
ZIZ
= 100µA TA = 25°C 1.219 1.225 1.231 1.213 1.225 1. 237 V
T
A
= -40 to +85°C 1.211 1.225 1.239 1. 201 1.225 1.249 V
Minimum Operating Current
I
Z(min)
30 60 30 60 µA
Reverse Breakdown Voltage Temperature Coefficient
I
Z
= 10mA
I
Z
= 1mA
I
Z
= 100µA
T
A
= -40 to +85°C ±100 ±150 ppm/°C
Ratio of Change in V
Z
to
Change in I
Z
I
Z(min)
< IZ < 1mA TA = 25°C 1.5 2.0 mV
TA = -40 to +85°C 2.0 2.5 mV
1mA <
IZ < 12mA TA = 25°C 6.0 8.0 mV
T
A
= -40 to +85°C 8.0 10.0 mV
Reverse Dynamic
Impedance
Z
RIZ
= 1mA, f = 120 Hz, IAC = 0.1 I
Z
0.25 1.5 0.25 2.0
Ω
Wideband Noise (RMS) e
NIZ
= 100µA
10Hz <
f < 10kHz
20 20 µV
Long Term Stability of Reverse Breakdown Voltage
t = 1000 hours
T = 25°C ± 0.1°C
I
Z
= 100µA
120 120 ppm
T
V
Z
∆
∆
Z
Z
I
V
∆
∆
Z
V
∆