www.hygroup.com.tw
Glass Passivated 3 Phase Bridge Rectifiers
SBR35GW SERIES
Reverse Voltage - 50 to 1600Volts
Forward Current - 35 Amperes
Features SBRW
● Low forward voltage drop
● High current capability
● High reliability
●Meet UL flammability classification 94V-0
Mechanical Data
● Case: Epoxy case with heat sink
● Polarity: Symbol marked on body
● Mounting position:
● Bolt pass through the mounting hole of body
then fixto heat sink
● Mounting torque: 2 N.m
Note: Products with logo or
are made by HY Electronic (Cayman) Limited.
Applications
● For use in high power supply inverters,servo
motor and welding machine applications
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Pb
RoHS
COMPLIANT
Package Outline Dimensions in Inches (Millimeters)
Characteristics Symbol
Maximum Repetitive Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 1200 1400 1600 V
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 840 980 1120 V
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 1200 1400 1600 V
Peak Non-Repetitive Reverse Voltage VRSM 75 150 275 500 725 900 1100 1300 1500 1700 V
Maximum Average Forward Rectified Current @TC=55 ℃
Peak Forward Surge Current, 8.3mS Single Half Sine-Wave,
Superimposed on Rated Load (JEDEC Method)
I2t Rating for Fusing (t<8.3mS)
Peak Forward Voltage per Diode at 17.5A DC
Maximum DC Reverse Current at Rated @TJ=25℃
DC Blocking Voltage per Diode @TJ=150℃
RMS lsolation Voltage from Case to Lead
Typical Thermal Resistance Junction to Case per Diode RθJC
Operating Junction Temperature Range TJ
Storage Temperature Range TSTG
Note: The typical data above is for reference only
00GW 01GW 02GW 04GW 06GW 08GW 10GW 12GW 14GW 16GW
I(AV) A
IFSM
I2 t
VF
IR
VISO
SBR35
35
450
840
1.1
5
3
2500
0.9
-40 to +150
-40 to +150
Unit
A2S
mA
℃/W
SBR35*GW-B-00/99/92-00/01
Rev. 11, 18-May-2020
A
V
μA
V
℃
℃

Rating and Characteristic Curves
SBR35GW SERIES
Fig. 1 - Forward Current Derating Curve
40
35
30
25
20
15
10
5
Average Forward Current (A)
0
0 50 100 150 200
Case Temperature (℃)
Fig. 3 - Typical Reverse Characteristics
2000
1000
100
10
TJ=150°C
TJ=125°C
TJ=100°C
TJ=75°C
Fig. 2 - Maximum Non-Repetitive Surge Current
500
450
400
350
300
250
200
150
100
Peak Forward Surge Current (A)
50
0
1 10 100
20
10
1
8.3mS Single Half-Sine-Wave
(JEDEC METOD)
Number of Cycles at 60Hz
Fig. 4 - Typical Forward Characteristics
TJ=100°C
TJ=25°C
TJ=125°C
TJ=75°C
1
Instantaneous Reverse Current (mA)
0
20 40 60 80 100
Percent of Rated Peak Reverse Voltage (%)
TJ=25°C
Instantaneous Forward Current (A)
0.1
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
Instantaneous Forward Voltage (V)
Pulse Width 300uS
2%Duty Cycle
The curve above is for reference only.
SBR35*GW-B-00/99/92-00/01
Rev. 11, 18-May-2020

Legal Disclaimer Notice
Disclaimer
ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons.
HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising
out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require-
ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi-
lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specifications may vary in different applications and performance may vary over time. All operating parameters, including typical paramet-
ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or
otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applications or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or
selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any
conduct of HY. Product names and markings noted herein may be trademarks of their respective owners.
Rev. 11, 18-May-2020