Datasheet RZ4855HDP0 Specification

Page 1
Specifications are subject to change without notice (30.06.1999) 1
Solid State Relay Switching mode Rated operational voltage Rated operational current Control voltage Option 1 (overvoltage protection) Option 2 (pilot duty switch)
A Solid State Relay family designed to switch various loads such as heating ele­ments, motors and transfor­mers. The relay is capable of switching high voltages up to 690 VACrms.
Technique
For higher reliability and load cycle capability three alter­nistor chips are soldered di­rectly on to the direct copper bonded (DCB) substrate. AC-
or DC-controlled versions are available. Built-in LED status indication for applied control voltage. Other features in­clude overvoltage protection via the varistors and the possibility of installing a ther­mostat for overtemperature protection. When equipped with a pilot duty switch and connected to a mechanical relay a hybrid function is achieved, and it is no longer necessary to use a heatsink.
Solid State Relays Industrial, 3-Phase ZS
Types RZ .... HD P., RZ .... HA P.
• 3-phase Solid State Relay
• Zero switching
• Rated operational current: 3 x 10, 25, 40 or 55 AACrms
• Rated operational voltage: Up to 690 VACrms
• Control voltage 10 to 40 VDC or 20 to 265 VAC/DC
• Transient overvoltage protection built-in
• Prepared for overtemperature protection
• Pilot duty switch available as an option
• IP 10 back-of-hand protection
Ordering KeyProduct Description
Type Selection
Switching Rated Rated Control Option 1 Option 2 mode operational operational voltage (protection) (pilot duty switch)
voltage current
RZ 40: 400 VACrms 10: 10 AACrms HD: 10 - 40 VDC P: Protected 0: Without PDS
48: 480 VACrms 25: 25 AACrms HA: 20 - 265 VAC/DC J: Unprotected 1: 1 A/230 VAC
40: 40 AACrms 2: 1 A/24 VDC 55: 55 AACrms
RZ 4010 HD P. RZ 4025 HD P. RZ 4040 HD P. RZ 4055 HD P. RZ 4010 HA P. RZ 4025 HA P. RZ 4040 HA P. RZ 4055 HA P. RZ 4810 HD P. RZ 4825 HD P. RZ 4840 HD P. RZ 4855 HD P. RZ 4810 HA P. RZ 4825 HA P. RZ 4840 HA P. RZ 4855 HA P.
Selection Guide
Control voltage
Rated opera­tional voltage
Rated operational current 10 AACrms 25 AACrms 40 AACrms 55 AACrms
20 - 265 VAC/DC 10 - 40 VDC 20 - 265 VAC/DC
480 VACrms
400 VACrms
10 - 40 VDC
1 Protection: unprotected version only available on request. 2 Pilot duty switch: add suffix 1 or 2 for pilot duty switch (e.g. 1 A/230 VAC). Example: RZ 4025 HDP1.
Ordering example for RZ-relay with built-in varistors and pilot duty switch: RZ 4025 HDP1.
Options
R Z 40 25 HD P0
This datasheet has been downloaded fromhttp://www.digchip.com at this page
Page 2
2 Specifications are subject to change without notice (30.06.1999)
General Specifications
RZ .... HD P., RZ .... HA P.
Input Specifications
RZ .... HD P0 RZ .... HA P0 RZ .... HD P2 RZ .... HA P1
Control voltage range 10 to 40 VDC 20 to 265 VAC/DC 10 to 40 VDC 20 to 265 VAC/DC
FELV-SELV-PELV FELV-SELV- FELV-SELV-PELV FELV-SELV-
PELV/line PELV/line
Pick-up voltage 10 VDC 20 VAC/DC 10 VDC 20 VAC/DC Drop-out voltage 3 VDC 5 VAC/DC 3 VDC 5 VAC/DC Input current
18 mADC @ 10 Vin≤ 20 mA AC/DC
18 mADC @ 10 Vin≤ 20 mA AC/DC
22 mADC @ 24 V
in
30 mADC @ 24 V
in
28 mADC @ 40 V
in
40 mADC @ 40 V
in
Response time pick-up
Power output 10 ms 10 ms 10 ms 10 ms Pilot duty switch - - 10 ms 10 ms
Response time drop-out
Power output 20 ms 40 ms 100 ms 100 ms Pilot duty switch - - 10 ms 20 ms
RZ ..10 .. P. RZ ..25 .. P. RZ ..40 .. P. RZ ..55 .. P.
Rated operational current
AC1 ratings 10 Arms 25 Arms 40 Arms 55 Arms AC3 ratings 2 Arms 5 Arms 8 Arms 15 Arms
Minimum operational current 100 mArms 100 mArms 200 mArms 200 mArms Rep. overload current t=1 s 18 Arms 37 Arms 60 Arms 85 Arms
t=5 s 15 Arms 32 Arms 50 Arms 70 Arms
Non-rep. surge current
t = 20 ms
120 A
p
230 A
p
300 A
p
550 A
p
Off-state leakage current 10 mArms 10 mArms 10 mArms 10 mArms I2t for fusing t = 1-10 ms 72 A2s £ 265 A2s 450 A2s 1500 A2s Critical dI/dt 50 A/µs 50 A/µs 100 A/µs 100 A/µs On-state voltage drop 1.6 Vrms 1.6 Vrms 1.6 Vrms 1.6 Vrms Critical dV/dt off state 500 V/µs 500 V/µs 500 V/µs 500 V/µs
Output Specifications
Star (load connected to neutral)
Delta
RZ 40.. .. P. RZ 48.. .. P.
Operational voltage ranges
Line to neutral 12 to 440 VACrms 12 to 530 VACrms Line to line 12 to 400 VACrms 12 to 660 VACrms (load connected to neutral)
Non-rep. peak voltage 1000 V
p
1200 V
p
Varistor voltage 420 VACrms 510 VACrms Operational frequency range 45 to 65 Hz 45 to 65 Hz Overvoltage category III III Pollution degree 3 2 Approvals CSA, UL CSA, UL CE-marking Yes Yes
Page 3
Specifications are subject to change without notice (30.06.1999) 3
RZ .. .. HD P., RZ .. .. HA P.
RZ ..10 .. .. RZ ..25 .. RZ ..40 .. RZ ..55 ..
Operating temperature -20° to +70°C -20° to +70°C -20° to +70°C -20° to +70°C
(-4° to +158°F) (-4° to +158°F) (-4° to +158°F) (-4° to +158°F)
Storage temperature -40° to +100°C -40° to +100°C -40° to +100°C -40° to +100°C
(-40° to +212°F) (-40° to +212°F) (-40° to +212°F) (-40° to +212°F)
Junction temperature 125°C (257°F) 125°C (257°F) 125°C (257°F) 125°C (257°F) R
th
junction to case 3-phase 0.75 K/W 0.5 K/W 0.3 K/W 0.2 K/W
1-phase 2.25 K/W 1.5 K/W 1.0 K/W 0.6 K/W
Thermal Specifications
Option 1 - Overvoltage Protection
Transients are generated by overvoltage of atmospheric origin on the public distribu­tion system or when motors, solenoids, valves, lights, heat­ers or any electrically oper­ated equipment are con­nected to or disconnected from the power source. To perform a transient voltage clipping or suppression func-
tion on the AC-load side of an RZ relay, metal oxide varistors (MOV) are normally built in. MOV's assume a low imped­ance state when their voltage threshold is exceeded. Car­lo Gavazzi SSR's are optio­nally available without varis­tors if no transient protec­tion is required.
Insulation
ACrms ACrms 3 cycles 1 min
Rated insulation voltage
Input to output 5660 V 4000 V
Input to pilot duty switch 5660 V 4000 V
Input to heatsink 5660 V 4000 V
Rated insulation voltage
Output to heatsink 4240 V 4000 V Output to output 4240 V 4000 V Output to pilot duty switch 4240 V 4000 V
Option 2 - Pilot Duty Switch
The RZ relay is available ei­ther with or without pilot duty switch (PDS). Equipped with the PDS and connected to a mechanical relay, a hybrid function is achieved and it is no longer necessary to use a heatsink. The built-in timing function of the relay will ensure that the switching on and switching off is carried out by the Solid State Relay. As soon as the control voltage is applied, the power output turns on and the full voltage is applied to
the load. After max. 10 ms, the PDS will activate the con­tactor shunting the SSR in about 20 ms. As the load is already under full voltage, the contactor does not take any high inrush currents. It only bypasses the SSR. When the control voltage is removed, the pilot duty switch will first disconnect the contactor. Af­ter a delay of min. 30 ms, the load will be switched off. The power outputs will be off max. 100 ms after the input control voltage has been removed.
PDS 01 PDS 02
Operational voltage range 24 to 280 VACrms 5 to 24 VDC Rated operational current 1 Arms @ 40°C 1 A @ 40°C
0.85 Arms @ 50°C 0.85 A @ 50°C0.7 Arms @ 60°C 0.7 A @ 60°C0.55 Arms @ 70°C 0.5 A @ 70°C
Non-rep. surge current t = 20 ms 30 A
p
­Rep. overload current t = 1s 5 Arms 2 A DC I2t for fusing t=1-10 ms 5 A2s­Off-state leakage current 1 mArms 1 mA DC On-state voltage 1.2 VACrms 1.5 VDC
Control voltage
Shunting contactor
Power output
td1≤100
td
1
10 ms
td
2
20
td2≈ 30 ms
td1= time delay semiconductor td
2
= time delay contactor
Page 4
4 Specifications are subject to change without notice (30.06.1999)
Heatsink Dimensions (load current versus ambient temperature)
RZ .... HD P., RZ .... HA P.
12
11
10
9
8
7
6
5
4
3
2
1.7 1.4 1.2 1.0 0.7 41
2.0 1.7 1.4 1.2 0.9 37
2.3 2.0 1.7 1.4 1.1 33
2.7 2.4 2.0 1.7 1.3 29
3.1 2.7 2.3 1.9 1.5 25
3.7 3.2 2.7 2.3 1.8 21
4.4 3.8 3.3 2.7 2.2 18
5.4 4.7 4.1 3.4 2.7 15
7.0 6.1 5.2 4.3 3.5 12
9.5 8.3 7.1 5.9 4.7 8
14.7 12.9 11.0 9.2 7.3 5
20 30 40 50 60
Load current [A]
Thermal resistance [K/W]
T
A
90°C
Temp. pro­tection [°C]
Power dissipation [W]
Ambient temp [°C]
RZ ..10.. ..
RZ ..40.. ..
Power dissipation [W]
0.26 - - - - 165
0.36 0.29 - - - 143
0.49 0.40 0.32 - - 122
0.65 0.55 0.46 0.36 0.26 103
0.87 0.76 0.64 0.52 0.40 84
1.2 1.1 0.90 0.75 0.60 67
1.5 1.4 1.2 1.0 0.78 51
2.2 2.0 1.7 1.4 1.1 37
3.5 3.1 2.7 2.2 1.8 23
7.4 6.5 5.6 4.6 3.7 11
20 30 40 50 60
Load current [A]
Thermal resistance [K/W]
Temp. pro­tection [°C]
40 36
32
28
24
20
16
12
8
4
Ambient temp [°C]
T
A
80°C
70°C
90°C
RZ ..25.. ..
Power dissipation [W]
0.46 0.36 0.26 - - 101
0.62 0.50 0.39 0.28 - 88
0.81 0.68 0.55 0.42 0.28 76
1.0 0.91 0.76 0.60 0.44 64
1.4 1.2 1.0 0.85 0.66 53
1.9 1.6 1.4 1.1 0.95 43
2.4 2.1 1.8 1.5 1.2 33
3.4 3.0 2.5 2.1 1.7 24
5.3 4.7 4.0 3.3 2.6 15
11.2 9.8 8.4 7.0 5.6 7
20 30 40 50 60
Load current [A]
Thermal resistance [K/W]
Temp. pro­tection [°C]
Ambient temp [°C]
T
A
90°C
80°C
70°C
RZ ..55.. ..
- - - - - 215
0.28 - - - - 191
0.35 0.29 - - - 167
0.45 0.38 0.31 - - 145
0.58 0.50 0.42 0.33 0.25 123
0.75 0.65 0.55 0.46 0.36 103
0.96 0.84 0.72 0.60 0.48 83
1.3 1.1 0.93 0.78 0.62 65
1.8 1.5 1.3 1.1 0.85 47
2.7 2.4 2.0 1.7 1.4 30
5.5 4.8 4.1 3.5 2.8 15
20 30 40 50 60
Load current [A]
Thermal resistance [K/W]
T
A
Temp. pro­tection [°C]
Power dissipation [W]
Ambient temp [°C]
55 50
45
40
35
30
25
20
15
10
5
80°C
90°C
25
22.5
20
17.5
15
12.5
10
7.5
5
2.5
Carlo Gavazzi Heatsink
(see Accessories)
No heatsink required RHS 300 Assy or backplate RHS 301 Assy RHS 301 F Assy Consult your distributor
Thermal resistance
R
th s-a
> 8.0 K/W
5.0 K/W
0.8 K/W
0.25 K/W
< 0.25 K/W
Heatsink Selection
Compare the value found in the load current versus tempe­rature chart with the standard heatsink values and select the heatsink with the next lower value.
It is recommended to protect the Solid State Relay against overheating. Therefore the chart also states the maximum switching temperature (70, 80 or 90°C) for the optional temperature limit switch.
Page 5
Specifications are subject to change without notice (30.06.1999) 5
RZ .. .. HD P., RZ .. .. HA P.
Dimensions
Functional Diagram
Housing Specifications Accessories
Protection cover For further information refer Heatsinks to “General Accessories”. Varistors Fuses Temperature limit switch
Load output
Mains input
Control inputs
N
Weight Approx. 380 g Material Noryl, glass reinforced
Colour Black Base plate Aluminum, nickel-plated Potting compound Polyurethane, black Relay
Mounting screws M5 Mounting torque 1.5 Nm
Control terminal
Mounting screws M3 Mounting torque 0.5 Nm Wire size Max. 2 x 2.5 mm
2
Min. 2 x 1.0 mm
2
Power terminal
Mounting screws M5 Mounting torque 2.5 Nm
2 x 6 mm
2
(AWG8)
Wire size Max. 2 x 6 mm
2
Min. 2 x 1 mm
2
Heat Sink Compound
Page 6
6 Specifications are subject to change without notice (30.06.1999)
RZ .. .. HD P., RZ .. .. HA P.
Applications
Selection Guide
Direct switching Selection Guide
Delta switching Selection Guide
380/400 V
Motor size [kW] [Arms]*
1.1 1.5
1.5 2.1
2.2 3.0
3.0 4.0
4.0 4.6
5.5 6,2
7.5 8.7
11.0 12.1
15.0 16.2
* I / √ 3.
Switching motor loads
Control
Control
Motor connections
Motor start with shunting by electromechanical relay (no heatsink needed)
Direct switching
Control
10 25 40 55
Relay type [A]
10 25 40 55
Relay type [A]
10 25 40 55
[kW] [Arms]
3.0 7.0
5.5 11.9
7.5 15.3
15 29
Relay type [A]
380/400 V
Motor size [kW] [Arms]
0.25 0.8
0.37 1.1
0.55 1.5
0.75 1.9
1.1 2.6
1.5 3.5
2.2 4.7
3.0 6.2
4.0 8.1
5.5 10.7
7.5 15.0
380/400 V
Motor size
Loading...