Specifications are subject to change without notice (30.06.1999) 3
RZ .. .. HD P., RZ .. .. HA P.
RZ ..10 .. .. RZ ..25 .. RZ ..40 .. RZ ..55 ..
Operating temperature -20° to +70°C -20° to +70°C -20° to +70°C -20° to +70°C
(-4° to +158°F) (-4° to +158°F) (-4° to +158°F) (-4° to +158°F)
Storage temperature -40° to +100°C -40° to +100°C -40° to +100°C -40° to +100°C
(-40° to +212°F) (-40° to +212°F) (-40° to +212°F) (-40° to +212°F)
Junction temperature ≤ 125°C (≤ 257°F) ≤ 125°C (≤ 257°F) ≤ 125°C (≤ 257°F) ≤ 125°C (≤ 257°F)
R
th
junction to case 3-phase 0.75 K/W 0.5 K/W 0.3 K/W 0.2 K/W
1-phase 2.25 K/W 1.5 K/W 1.0 K/W 0.6 K/W
Thermal Specifications
Option 1 - Overvoltage Protection
Transients are generated by
overvoltage of atmospheric
origin on the public distribution system or when motors,
solenoids, valves, lights, heaters or any electrically operated equipment are connected to or disconnected
from the power source. To
perform a transient voltage
clipping or suppression func-
tion on the AC-load side of an
RZ relay, metal oxide varistors
(MOV) are normally built in.
MOV's assume a low impedance state when their voltage
threshold is exceeded. Carlo Gavazzi SSR's are optionally available without varistors if no transient protection is required.
Insulation
ACrms ACrms
3 cycles 1 min
Rated insulation voltage
Input to output ≥ 5660 V ≥ 4000 V
Input to pilot duty switch ≥ 5660 V ≥ 4000 V
Input to heatsink ≥ 5660 V ≥ 4000 V
Rated insulation voltage
Output to heatsink ≥ 4240 V ≥ 4000 V
Output to output ≥ 4240 V ≥ 4000 V
Output to pilot duty switch ≥ 4240 V ≥ 4000 V
Option 2 - Pilot Duty Switch
The RZ relay is available either with or without pilot duty
switch (PDS).
Equipped with the PDS and
connected to a mechanical
relay, a hybrid function is
achieved and it is no longer
necessary to use a heatsink.
The built-in timing function of
the relay will ensure that the
switching on and switching
off is carried out by the Solid
State Relay. As soon as the
control voltage is applied, the
power output turns on and
the full voltage is applied to
the load. After max. 10 ms,
the PDS will activate the contactor shunting the SSR in
about 20 ms. As the load is
already under full voltage, the
contactor does not take any
high inrush currents. It only
bypasses the SSR. When the
control voltage is removed,
the pilot duty switch will first
disconnect the contactor. After a delay of min. 30 ms, the
load will be switched off. The
power outputs will be off max.
100 ms after the input control
voltage has been removed.
PDS 01 PDS 02
Operational voltage range 24 to 280 VACrms 5 to 24 VDC
Rated operational current ≤ 1 Arms @ 40°C ≤ 1 A @ 40°C
≤ 0.85 Arms @ 50°C ≤ 0.85 A @ 50°C
≤ 0.7 Arms @ 60°C ≤ 0.7 A @ 60°C
≤ 0.55 Arms @ 70°C ≤ 0.5 A @ 70°C
Non-rep. surge current
t = 20 ms 30 A
p
Rep. overload current t = 1s 5 Arms 2 A DC
I2t for fusing t=1-10 ms 5 A2sOff-state leakage current ≤ 1 mArms ≤ 1 mA DC
On-state voltage 1.2 VACrms 1.5 VDC
Control voltage
Shunting
contactor
Power output
td1≤100
td
1
≤ 10 ms
td
2
≈ 20
td2≈ 30 ms
td1= time delay semiconductor
td
2
= time delay contactor