General Purpose
Z
b
Low Power PCB Relays
Power PCB Relay RT2 DC and AC (for global markets)
n
2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
n
DC or AC coil
n
5kV/10mm coil-contact, reinforced insulation
n
Ambient temperature up to 85°C
n
WG version: product in accordance to IEC60335-1
n
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications Boiler control, timers, garage door control, POS automation, interface modules.
SCHRACK
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
Contact arrangement 2 form C (CO) or 2 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Rated current 8A, UL: 10A Limiting continuous current 8A, UL: 10A Limiting making current, max. 4s, duty factor 10% 15A Breaking capacity max. 2000VA Contact material AgNi 90/10, AgNi 90/10 gold plated, AgSnO Frequency of operation, with/without load DC coil 360/72000h-1 AC coil 360/36000h Operate/release time max., DC coil 8/6ms Bounce time max., DC coil, form A/form B 4/10ms Electrical endurance see electrical endurance graph
Contact ratings
Type Contact Load Cycles
IEC 61810
RT424 DC coil C (CO) 8A, 250VAC, cosφ=1, 85°C 10x10 RT444 AC coil A (NO) 8A, 250VAC, cosφ=1, 70°C 50x103 RT424 AC coil C (CO) 8A, 250VAC, cosφ=1, 70°C 30x10
UL 508
RT424 DC coil A/B (NO/NC) 10A, 250VAC, gen. purpose, 85°C 20x10 RT424 DC coil A/B (NO/NC) 1/2hp, 240VAC, 85°C 1x103 RT424 DC coil A/B (NO/NC) Pilot duty, B300, R300, 85°C 6x10
EN60947-5-1
RTE24 DC coil A/B (NO/NC) AC15, 250VAC, 3A 6.050 RTE24 DC coil A/B (NO/NC) DC13, 24VDC, 2A 6.050 RTE24 DC coil A/B (NO/NC) DC13, 250VDC, 0.2A 6.050
EN60730-1
RT424 DC coil A/B (NO/NC) 6(2)A, 250VAC, 85°C 100x10
1) For reflow solderable versions: actual contact performance may be influenced by the reflow soldering process.
2
-1
1)
Contact Data (continued)
Mechanical endurance DC coil >30x106 operations DC coil, reflow version >10x106 operations AC coil >5x106 operations AC coil, reflow version >2x106 operations
Coil Data
Coil voltage range, DC coil/AC coil 5 to 110VDC / 24 to 230VAC Operative range, IEC 61810 2 Coil insulation system according UL class F
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10%2) mW 005 5 3.5 0.5 62 403 006 6 4.2 0.6 90 400 009 9 6.3 0.9 200 400 012 12 8.4 1.2 360 400 024 24 16.8 2.4 1440 400 048 48 33.6 4.8 5520 417 060 60 42.0 6.0 85702) 420 110 110 77.0 11.0 288002) 420
3
2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient temperature +23°C. Other coil voltages on request.
3
Coil versions, AC coil 50Hz
Coil Rated Operate Release Coil Rated coil
3
code voltage voltage voltage resistance power VAC VAC VAC Ω±15%3) VA
3
524 24 18.0 3.6 350 615 115 86.3 17.3 8100 0.76 620 120 90.0 18.0 8800 0.75 700 200 150.0 30.0 24350 0.76 730 230 172.5 34.5 32500 0.74
3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient
3
temperature +23°C, 50Hz. Other coil voltages on request.
3)
0.76
10-2014, Rev. 1014 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company.
Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Catalog product data, ‘Definitions’ section,
1
application notes and all specifications are subject to change.
Page 2
General Purpose Low Power PCB Relays
SCHRACK
Power PCB Relay RT2 DC and AC (for global markets)
Insulation Data
Initial dielectric strength between open contacts 1000V between contact and coil 5000V between adjacent contacts 2500V Clearance/creepage between contact and coil ≥10/10mm between adjacent contacts ≥3/4mm Material group of insulation parts IIIa Tracking index of relay base PTI 250V reflow version PTI 175V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Resistance to heat and fire WG version or reflow version according EN60335, par30 Ambient temperature DC coil -40 to 85°C AC coil -40 to 70°C AgSnO2 contacts -40 to 70°C Category of environmental protection, IEC 61810 standard version RTII - flux proof, RTIII - wash tight reflow version RTII - flux proof Vibration resistance (functional), form A/form B contact, 30 to 300Hz 20g/5g Shock resistance (destructive) 100g
rms
rms
rms
(Continued)
Other Data (continued)
Terminal type PCB-THT, plug-in reflow version PCB-THR Mounting distance, AC coil ≥2.5mm Weight 13g Resistance to soldering heat THT, IEC 60068-2-20 RTII 270°C/10s RTIII 260°C/5s Resistance to soldering heat THR reflow soldering (for reflow version) forced gas convection 4) or vapour phase 5) temperature profile according EN61730 Packaging/unit tube/20pcs., box/500pcs.
4) infrared heating not allowed.
5) recommended fluid LS/230.
Accessories
For details see datasheet NOTE: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1); for relays mounted on sockets deratings may apply.
Accessories Industrial Power Relay RT
Dimensions
THT version THR version (reflow solderable)
Process conditions for Reflow soldering
according to EN61760-1
PCB layout / terminal assignment
Bottom view on solder pins
*) With the recommended PCB hole sizes a grid pattern from 2.5 mm to 2.54 mm can be used.
2 form C (CO) contacts
2 form A (NO) contacts
2
10-2014, Rev. 1014 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company.
Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change.
Page 3
General Purpose Low Power PCB Relays
SCHRACK
Power PCB Relay RT2 DC and AC (for global markets)
(Continued)
Product code structure Typical product code RT 4 2 4 024
Type RT Power PCB Relay RT2 Version
4 8A, pinning 5mm, flux proof E 8A, pinning 5mm, wash tight (not for Reflow version)
Contact arrangement
2 2 form C (CO) contacts 4 2 form A (NO) contacts
Contact material
3 AgSnO 4 AgNi 90/10 5 AgNi 90/10 gold plated
Coil Coil code: please refer to coil versions table Version
Blank Standard version WG Product in accordance with IEC 60335-1 (domestic appliances) R Reflow solderable
Product code Version Contacts Contact material Coil Version Part number
RT423730 8A, 2 form C (CO) AgSnO 230VAC Standard 4-1393243-3 RT424005 pinning 5mm, contacts AgNi 90/10 5VDC 5-1393243-9 RT424006 flux proof 6VDC 6-1393243-1 RT424012 12VDC 6-1393243-3 RT424012WG IEC60335-1 compliant 7-1415538-8 RT424024 24VDC Standard 6-1393243-8 RT424024WG IEC60335-1 compliant 7-1415538-7 RT424048 48VDC Standard 7-1393243-0 RT424060 60VDC 7-1393243-3 RT424110 110VDC 7-1393243-5 RT424524 24VAC 7-1393243-6 RT424615 115VAC 7-1393243-8 RT424730 230VAC 7-1393243-9 RT425003 AgNi 90/10 3VDC 7-1415525-1 RT425005 gold plated 5VDC 8-1393243-0 RT425012 12VDC 8-1393243-2 RT425024 24VDC 8-1393243-5 RT444012 2 form A (NO) AgNi 90/10 12VDC 9-1393243-7 RT444024 contacts 24VDC 9-1393243-9 RTE24005 8A, 2 form C (CO) 5VDC 1393243-1 RTE24006 pinning 5mm, contacts 6VDC 1393243-2 RTE24012 wash tight 12VDC 1393243-4 RTE24024 24VDC 1-1393243-0 RTE24048 48VDC 1-1393243-1 RTE24110 110VDC 1-1393243-4 RTE24524 24VAC 1-1393243-5 RTE24615 115VAC 1-1393243-7 RTE24730 230VAC 1-1393243-8 RTE25005 AgNi 90/10 5VDC 1-1393243-9 RTE25012 gold plated 12VDC 2-1393243-0 RTE25024 24VDC 2-1393243-1 RTE25524 2-1393243-4 RTE43009 2 form A (NO) AgSnO 9VDC 4-1415535-1 RTE44009 contacts AgNi 90/10 3-1393243-1 RTE44730 230VAC 3-1393243-5
This list represents the most common types and does not show all variants covered by this datasheet. Other types on request.
10-2014, Rev. 1014 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company.
Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Catalog product data, ‘Definitions’ section,
3
application notes and all specifications are subject to change.
Page 4
Loading...