General Purpose Relays
PCB Relays
Power PCB Relay RT1 bistable
n
1 pole 16A, 1 form C (CO) or 1 form A (NO) contact
n
Polarized bistable version with 1 or 2 coils
n
5kV/10mm coil-contact
n
Reinforced insulation
Typical applications
Battery powered equipment or applications with “memory function”
SCHRACK
F0176-C
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 16A
Limiting continuous current 16A, UL: 20A
Limiting making current, max. 4s, duty factor 10% 30A
Breaking capacity max. 4000VA
Contact material AgNi 90/10
Frequency of operation, with/without load 360/72000h
Operate/Reset time max. 10/10ms
Bounce time max., form A/form B 3/6ms
Contact ratings
Type Contact Load Cycles
IEC 61810
RT314 A (NO) 16A, 250VAC resistive, 85°C 30x10
RT314 C (CO) 16A, 250VAC resistive, 85°C 10x10
UL 508
RT314 A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x10
RT334 A (NO) 16A, 250VAC, general purpose, 85°C 50x103
RT314 A (NO) 1hp, 240VAC, 40°C 1x10
Mechanical endurance >5x106 operations
-1
Coil Data, bistable coils 1 coil 2 coils
Magnetic system polarized, bistable
Coil voltage range 3 to 24VDC
Operative range, IEC 61810 2
Limiting voltage, % of rated coil voltage 120% 150%
Min./Max. energization duration 30ms/1min at <10% duty factor
Coil insulation system according UL1446 class F
Coil versions, bistable coil
Coil Rated Set Reset Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
bistable 1 coil
A03 3 2.1 1.7 21 429
A05 5 3.5 2.8 62 403
A06 6 4.2 3.3 90 400
A12 12 8.4 6.6 360 400
A24 24 16.8 13.2 1440 400
bistable 2 coils
F03 3 2.1 1.7 15 600
3
F05 5 3.5 2.8 42 595
3
F06 6 4.2 3.3 55 655
F12 12 8.4 6.6 240 600
3
F24 24 16.8 13.2 886 650
All figures are given for coil without pre-energization, at ambient temperature +23°C.
3
Other coil voltages on request.
Bistable coils - operation
Version 1 coil 2 coils
Coil terminals A1 A2 A1 A3 A2
Operate + - + -
Reset - + - +
Contact position not defined at delivery
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
1
tion, application notes and all specifications
are subject to change.

General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1 bistable
Insulation Data
Initial dielectric strength
between open contacts 1000V
between contact and coil 5000V
Clearance/creepage
between contact and coil ≥ 10/10mm
Material group of insulation parts IIIa
Tracking index of relay base PTI 250V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature -40 to 85°C
Category of environmental protection
IEC 61810 RTII - flux proof, RTIII - wash tight
Vibration/shock resistance (functional),
opening B contact 3/5g
opening closed A contact 6/15g
Shock resistance (destructive) 100g
Dimensions
rms
rms
(Continued)
Other Data (continued)
Terminal type PCB-THT, plug-in
Weight 14g
Resistance to soldering heat THT, IEC 60068-2-20
RTII - flux proof 270°C/10s
RTIII - wash tight 260°C/5s
Packaging/unit tube/20 pcs., box/500 pcs.
1) socket available for 1 coil version only, see Accessories.
1)
Accessories
For 1 coil version,
details see datasheet
NOTE: indicated contact ratings and electrical endurance data for direct
wiring of relays (according IEC 61810-1); for relays mounted on sockets
deratings may apply.
PCB layout / terminal assignment
Bottom view on solder pins
Accessories Industrial Power Relay RT
S0272-BC
a) Indicated contact position during or after coil
energization with reset voltage.
b) for 2 coil version only
12A, pinning 3,5mm, 1 form A (NO) contact
16 A, pinning 5 mm, 1 form A (NO) contact
S0418-CM
*) With the recommended PCB hole sizes a grid
pattern from 2.5 mm to 2.54 mm can be used.
16 A, pinning 5 mm, 1 form C (CO) contact
S0418-CM
*) With the recommended PCB hole sizes a grid
pattern from 2.5 mm to 2.54 mm can be used.
S0163-DI
S0163-DI
a)
a)
2
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.

General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1 bistable
(Continued)
Product code structure Typical product code RT 3 1 4 F24
Type
RT Power PCB Relay RT1 bistable
Version
1 12A, pinning 3,5mm, flux proof 3 16A, pinning 5mm, flux proof D 16A, pinning 5mm, wash tight
Contact configuration
1 1 form C (CO) contact 3 1 form A (NO) contact
Contact material
4 AgNi 90/10
Coil
Coil code: please refer to coil versions table
Product code Version Contacts Contact material Coil version Coil Part number
RT314A03 16A; 1 form C (CO) AgNi 90/10 Bistable 1coil
RT314A05 pinning 5mm, contact 5VDC 7-1393239-8
RT314A06 flux proof 6VDC 7-1393239-9
RT314A12 12VDC 8-1393239-0
RT314F03
RT314F05 5VDC 8-1393239-5
RT314F06 6VDC 8-1393239-6
RT314F12 12VDC 8-1393239-7
RT314F24
RT134F12
Other types on request.
This list represents the most common types and does not show all variants covered by this datasheet.
pinning 3,5mm,
12A,
flux proof
1 form A (NO)
contact
AgNi 90/10
Bistable 2 coils
Bistable 2 coils
3VDC
3VDC 8-1393239-4
24VDC
12VDC 4-1415382-1
7-1393239-7
8-1393239-8
10-2014, Rev. 1014
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
3
tion, application notes and all specifications
are subject to change.