Datasheet RP40-120512DE, RP40-120515DE, RP40-4815SE, RP40-483.305DE, RP40-483.3SE Datasheet (RECOM)

...
Page 1
PO 63www.recom-international.com August 2002
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
40 Watts Output Power
2:1 Wide Input Voltage Range
International Safety Standard
Design
High Efficiency up to 90%
Standard Package,
76.2 mm x 66.0 mm x 10.2 mm
Fixed Switching Frequency
Features
Selection Guide 12V, 24V and 48V Input Types
Part Number Input Output Output Input Current Efficiency Capacitive
Voltage Voltage Current (see note 6) (see note 7) Load
max.
VDC VDC mA mA % µF
RP40-123.3SE 9-18 3.3 10000 3530 83 25800
RP40-1205SE 9-18 5 8000 4170 84 13600
RP40-1212SE 9-18 12 3400 4100 87 2400
RP40-1215SE 9-18 15 2700 4100 87 1550
RP40-1205DE 9-18 ±5 +7000 / –1000 4330 81 12000 / 1700
RP40-1212DE 9-18 ±12 ±1800 4550 83 ±1200
RP40-1215DE 9-18 ±15 ±1400 4430 83 ±750
RP40-123.305DE 9-18 3.3 / 5 4000 / 4000 3730 78 10300 / 6800
RP40-120512TE 9-18 5 / ±12 4000 / ±850 4490 79 6800 / ±590
RP40-120515TE 9-18 5 / ±15 4000 / ±680 4430 80 6800 / ±380
RP40-243.3SE 18-36 3.3 10000 1720 84 25800
RP40-2405SE 18-36 5 8000 2010 87 13600
RP40-2412SE 18-36 12 3400 1980 90 2400
RP40-2415SE 18-36 15 2700 2000 88 1550
RP40-2405DE 18-36 ±5 +7000 / –1000 2130 82 12000 / 1700
RP40-2412DE 18-36 ±12 ±1800 2170 87 ±1200
RP40-2415DE 18-36 ±15 ±1400 2140 86 ±750
RP40-243.305DE 18-36 3.3 / 5 4000 / 4000 1840 79 10300 / 6800
RP40-240512TE 18-36 5 / ±12 4000 / ±850 2180 81 6800 / ±590
RP40-240515TE 18-36 5 / ±15 4000 / ±680 2160 82 6800 / ±380
RP40-483.3SE 36-75 3.3 10000 850 85 25800
RP40-4805SE 36-75 5 8000 980 89 13600
RP40-4812SE 36-75 12 3400 1000 89 2400
RP40-4815SE 36-75 15 2700 1000 88 1550
RP40-4805DE 36-75 ±5 +7000 / –1000 1060 84 12000 / 1700
RP40-4812DE 36-75 ±12 ±1800 1100 86 ±1200
RP40-4815DE 36-75 ±15 ±1400 1100 86 ±750
RP40-483.305DE 36-75 3.3 / 5 4000 / 4000 910 80 10300 / 6800
RP40-480512TE 36-75 5 / ±12 4000 / ±850 1060 83 6800 / ±590
RP40-480515TE 36-75 5 / ±15 4000 / ±680 1060 83 6800 / ±380
Page 2
PO 64 www.recom-international.comAugust 2002
Specifications (typical at nominal input and 25°C unless otherwise noted)
Output Power 40W max.
Voltage Accuracy (full Load and nominal Vin) Single & Dual ±2%
Triple 3.3V / 5V ±2% Auxiliary ±5%
Voltage Adjustability ±10%
Minimum Load (see note 1) RP40-xx3.305DE 3.3V output 20% min.
Others 10% of full load
Line Regulation (LL-HL at FL) Single (Dual) ±0.5% (±1%)
Triple 3.3V / 5V ±2% Auxiliary ±5%
Load Regulation (10% to 100% FL) Single ±0.5%
Dual ±1% Triple 3.3V / 5V ±2% Auxiliary ±5%
Cross Regulation (see note 2) Dual ±1%
Triple 3.3V / 5V ±1% Auxiliary ±5%
Ripple and Noise (20MHz BW) 1% pk-pk of Vout
Temperature Coefficient ±0.02%/°C max. Transient Response Recovery Time (25% load step change) 500µsec
Over Voltage (zener diode clamp) 3.3V output 3.9V
5V output 6.2V 12V output 15V 15V output 18V
Short Circuit Protection Hiccup, Automatic Recovery
Input Voltage Range 12V types nominal input 9-18VDC
24V types nominal input 18-36VDC 48V types nominal input 36-75VDC
Input Filter Pi Type
Input Surge Voltage (100 ms max.) 12V input 36VDC
24V input 50VDC 48V input 100VDC
Input Reflected Ripple (see note 3) Nominal Vin 40mAp-p
continued on next page
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
RP40-4805SE: Derating & Efficiency Curves
125
75
50
25
0
100
Ambient Temperature Range (°C)
-40-25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
91
83 82
80
Input Voltage (V)
36
Efficiency (%)
84
85
86
87
88
89
90
81
40 55 6545 50 7060 75
91
70 60
45
Output Load (A)
0, 5
Efficiency (%)
80
82
84
86
88
89
90
50
15834 67
2
RP40-4805SE Efficiency vs Output LoadRP40-4805SE Efficiency vs Input VoltageRP40-4805SE Derating Curve
Page 3
www.recom-international.com PO 65August 2002
Specifications continued (typical at nominal input and 25°C unless otherwise noted)
Start Up Time (nominal Vin and constant resistor load) 25ms typ.
Remote ON/OFF (see note 4) DC-DC ON Open or 3.5V < Vr < 12V
DC-DC OFF Short or 0V < Vr < 1.2V
Remote Off Input Current 30mA
Efficiency See „Selection Guide“ table“
Isolation Voltage 1600VDC
Isolation Resistance 109Ω
Isolation Capacitance 500pF
Switching Frequency 185kHz
Designed to Meet Safety Standard UL 1950, EN60950
Case Material Nickel-coated copper
Base Material Non-conducted black FR4
Potting Material Epoxy (UL94-V0)
Weight 125g
Dimensions 70.2 x 66.0 x 10.2 mm
MTBF (see note 5) 1.590 x 106Hours
Operating Temperature Range -40°C to +85°C (with derating)
Maximum Case Temperature +100°C
Storage Temperature Range –55°C to +105°C
Thermal Impedance Natural convection 5.7°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity 5% to 95% RH
Conducted Emissions EN55022 Level A
Radiated Emissions EN55022 Level A
Conducted Immunity EN61000-4-6 Perf. Criteria 2
Radiated Immunity EN61000-4-3 Perf. Criteria 2
Surge EN61000-4-5 Perf. Criteria 2
Fast Transient EN61000-4-4 Perf. Criteria 2
ESD EN61000-4-2 Perf. Criteria 2
Notes:
1. The RP40 E-series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification.
2. Cross regulation: Dual output–Asymmetrical load 25% to 100% full load.
Triple output - 3.3V/ 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load.
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. The ON-OFF control pin voltage is reference to negative input.
5. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40 °C (ground fixed and controlled environment).
6. Maximum value at nominal input voltage and full load.
7. Typical value at nominal input voltage and full load.
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Page 4
PO 66 www.recom-international.comAugust 2002
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Pin Pitch Tolerance ±0.35 mm
Package Style and Pinning (mm)
External Output Trimming
5
23
Bottom
View
1
7
7.60
63.50
dia.
1.0
8.00
7.6
66.00
15.20
689
76.20
10
7.60
4
10.20
10.20
17.80
10.20
10.20
12.70
10.20 10.20
Pin Connections
Pin # Single Dual Triple 3.5V / 5V
1Ctrl Ctrl Ctrl Ctrl 2 +Vin +Vin +Vin +Vin 3 –Vin –Vin –Vin –Vin 4 Sync Sync Sync Sync
5Trim Down +Vout +Aux +3.3V 6Trim Common Common (Aux) Common
7Trim Up –Vout –Aux +5V 8+Vout Trim +Vout Trim 9–Vout NC –Vout NC
10 No Pin NC Trim NC
Tri m
Up
Tri m
Down
Single Dual Triple 3.3V / 5V
7796
68108
5585
Page 5
www.recom-international.com PO 67August 2002
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Application of Synchronization
Converter 2
Converter 1
Sync
+
Sync
+
CLK
2
4
3
2
4
3
+
Vin
Vin
2N7000
20%
CLK Signal
80%
Converter
CTRL
+
ON/OFF Control
2
1
3
+
Vin
Vin
1. The unit is capable of external synchronization from an independent time base with a switching rate between 200kHz and 215 kHz.
2. The amplitude of the synchronizing pulse train is TTL compatible.
3. The duty cycle of the CLK should be 20% high and 80% low.
4. Synchronization is referenced to negative input
(–Vin).
Loading...