Specifications continued (typical at nominal input and 25°C unless otherwise noted)
Start Up Time (nominal Vin and constant resistor load) 25ms typ.
Remote ON/OFF (see note 4) DC-DC ON Open or 3.5V < Vr < 12V
DC-DC OFF Short or 0V < Vr < 1.2V
Remote Off Input Current 30mA
Efficiency See „Selection Guide“ table“
Isolation Voltage 1600VDC
Isolation Resistance 109Ω
Isolation Capacitance 500pF
Switching Frequency 185kHz
Designed to Meet Safety Standard UL 1950, EN60950
Case Material Nickel-coated copper
Base Material Non-conducted black FR4
Potting Material Epoxy (UL94-V0)
Weight 125g
Dimensions 70.2 x 66.0 x 10.2 mm
MTBF (see note 5) 1.590 x 106Hours
Operating Temperature Range -40°C to +85°C (with derating)
Maximum Case Temperature +100°C
Storage Temperature Range –55°C to +105°C
Thermal Impedance Natural convection 5.7°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity 5% to 95% RH
Conducted Emissions EN55022 Level A
Radiated Emissions EN55022 Level A
Conducted Immunity EN61000-4-6 Perf. Criteria 2
Radiated Immunity EN61000-4-3 Perf. Criteria 2
Surge EN61000-4-5 Perf. Criteria 2
Fast Transient EN61000-4-4 Perf. Criteria 2
ESD EN61000-4-2 Perf. Criteria 2
Notes:
1. The RP40 E-series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these
devices, however they may not meet all listed specification.
2. Cross regulation: Dual output–Asymmetrical load 25% to 100% full load.
Triple output - 3.3V/ 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load.
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. The ON-OFF control pin voltage is reference to negative input.
5. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40 °C (ground fixed and controlled environment).
6. Maximum value at nominal input voltage and full load.
7. Typical value at nominal input voltage and full load.
POWERLINE - DC/DC-Converter
E-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)