RM32N
miniature relays
• DC coils - of up to 24 V DC, low coil power 0,20 W (sensitive version)
or 0,45 W (standard version)
• For PCB • Very small dimensions, light weight
• High load up to 10 A / 125 V AC
• Application: for household electrical appliance, automation systems,
electrical equipment, instrument and meter, telecommunication
devices, remote control facilities, light controllers, etc.
Contact data
Number and type of contacts
Contact material
Rated / max. switching voltage AC
Min. switching voltage
Rated load AC1
DC1
Rated current
Max. breaking capacity AC1
AC3
Contact resistance
Coil data
Rated voltage DC
Must release voltage
Operating range of supply voltage
Rated power consumption DC
Insulation according to PN-EN 60664-1
Insulation resistance
Dielectric strength
• between coil and contacts
• contact clearance
General data
Operating / release time (typical values)
Electrical life (number of cycles)
• resistive AC1 1 800 cycles/hour
• resistive DC1 1 800 cycles/hour
Mechanical life 18 000 cycles/hour
Dimensions (L x W x H)
Weight
Ambient temperature • operating
Cover protection category
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
The data in bold type pertain to the standard versions of the relays.
❶ Only for contacts 1 NO
• Recognitions, certi cations, directives: RoHS,
1 CO, 1 NO
AgSnO
250 V / 277 V
5 V
1 CO: 5 A / 5 A (NO/NC) / 250 V AC 1 NO: 5 A / 250 V AC
1 CO: 10 A / 125 V AC ❶ 1 NO: 10 A / 125 V AC
1 CO: 5 A / 5 A (NO/NC) / 28 V DC 1 NO: 5 A / 28 V DC
5 A
1 250 VA
186 W 0,25 HP
100 m
5 ... 24 V
DC: 0,05 Un
see Tables 1, 2
0,20 W
100 M 500 V DC, 60 s
2 500 V AC type of insulation: basic
1 000 V AC type of clearance: micro-disconnection
8 ms / 5 ms
10
10
10
18,8 x 10,6 x 15,3 mm
6 g
-40...+70
IP 64
10 g
1,5 mm DA
max. 235 oC
max. 3 s
❶
2
UL 508 (single-phase motor)
sensitive version ❶ 0,45 W standard version
5
1 CO: 5 A / 5 A (NO/NC), 250 V AC 1 NO: 5 A, 250 V AC
5
1 CO: 5 A / 5 A (NO/NC), 28 V DC 1 NO: 5 A, 28 V DC
7
o
C
PN-EN 60529
(constant amplitude) 10...55 Hz
www.relpol.com.pl
14.07.2014
1
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl

RM32N
miniature relays
Coil data - DC voltage version, sensitive Table 1
Coil operating range
V DC
min. (at 20 °C) max. (at 20 °C)
3,75
6,75
9,00
13,50
18,00
6,5
11,7
15,6
23,4
31,2
Coil code
S005
S009
S012
S018
S024
❶
Rated voltage
V DC
5
9
12
18
24
Coil resistance
at 20 °C
125
405
720
1 620
2 880
Acceptable
resistance
± 10%
± 10%
± 10%
± 10%
± 10%
❶ Only for contacts 1 NO
Coil data - DC voltage version, standard Table 2
Coil code
1005
1009
1012
1018
1024
Dimensions
Rated voltage
V DC
5
9
12
18
24
Coil resistance
at 20 °C
56
180
320
720
1 280
Acceptable
resistance
± 10%
± 10%
± 10%
± 10%
± 10%
Connection diagrams (pin side view)
Coil operating range
V DC
min. (at 20 °C) max. (at 20 °C)
3,75
6,75
9,00
13,50
18,00
6,5
11,7
15,6
23,4
31,2
18,8
15,33,8
0,4
0,3
12,7 2,54
1,7
1 CO
1 NO
0,8
10,6
7,62
A1 11
A2 14
A1 11
A2 14
12
1 CO
1 NO
www.relpol.com.pl
14.07.2014
2
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl

RM32N
miniature relays
Pinout (solder side view)
1 CO 1 NO
11,2 1,5 2,54
12,7 2,54
7,62
5ר1,3 2,54×2,54
Mounting
Relays RM32N are designed for direct PCB mounting.
Ordering codes
M 3 2 N
R
Contact material
30 - AgSnO2
Type Number and type
material
— — —
of contacts
4ר1,3 2,54×2,54
Cover protection
category
Connection
mode
7,62
Coil codeContact
Number and type of contacts
11 - 1 CO
21 - 1 NO
Cover protection category
8 - in cover, IP 64 version
Connection mode
5 - for PCB
see Tables 1, 2 page 2
Examples of ordering codes:
RM32N-3021-85-S018 relay RM32N, for PCB, one normally open contact, contact material AgSnO
2, sensitive
coil voltage 18 V DC, in cover IP 64
RM32N-3011-85-1024 relay RM32N, for PCB, one changeover contact, contact material AgSnO
2, standard
coil voltage 24 V DC, in cover IP 64
PRECAUTIONS:
1. Ensure that the parameters of the product described in its specication provide a safety margin for the appropriate operation of the device or system and never use
the product in circumstances which exceed the parameters of the product. 2. Never touch any live parts of the device. 3. Ensure that the product has been connected
correctly. An incorrect connection may cause malfunction, excessive heating or risk of re. 4. In case of any risk of any serious material loss or death or injuries
of humans or animals, the devices or systems shall be designed so to equip them with double safety system to guarantee their reliable operation.
14.07.2014
www.relpol.com.pl
3
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl