3, 4.5, 5, 6, 9, 12, 24 V
Operating function Coil voltage, DC
24V
1.5 GHz MICROW AVE RELAY
9.7
mm inch
SPECIFICATIONS
Contact
Arrangement Contact material Initial contact resistance, max.
(By HP4328A)
Max. switching power Max. switching voltage
Rating
High frequency characteristics (
Impedance 50
Expected life (min. operations)
Max. switching current Nominal switching
capacity Isolation
Insertion loss
)
V.S.W.R. Mechanical
Electrical
0.01 A 24 V DC 10 W 1.2 GHz
0.01 A 24 V DC 10 W (at
1.2 GHz, Impedance 50)
Coil (at 25°C, 68°F)
Single side stable 200 mW 1 coil latching 2 coil latching
1 Form C Gold-clad
100 m
10 W
30 V DC
0.5 A
Min. 60 dB (at 1.5 GHz) Max. 0.3 dB (at 900 MHz) Max. 1.5 (at 900 MHz)
5×10 3×10
Nominal operating power
200 mW 400 mW
10
RK-RELAYS
• Excellent high frequency characteristics Isolation: Min. 60dB (at 1.5 GHz) Insertion loss: Max. 0.3dB (at 900 MHz)
• V.S.W.R.: Max. 1.5 (at 900MHz)
• High sensitivity in small size Size: 20.2 × 11.2 × 9.7 mm .795 × .441 × .382 inch Nominal power consumption: 200 mW (single side stable type)
• Sealed construction for automatic cleaning
• Latching types are also available
Characteristics
Initial insulation resistance*
Initial breakdown voltage*
Operate time [Set time]*3 (at nominal voltage) Release time (without diode) [Reset time]*
(at nominal voltage) *2
Temperature rise
6
5
5
Shock resistance
Vibration resistance
Conditions for operation, transport and storage
(Not freezing and condensing at low temperature)
Unit weight
Remarks
* Specifications will vary with foreign standards certification ratings.
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms, detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
Between open contacts Between contact and coil
2
Between contact and earth terminal
1
Functional* Destructive*
Functional*
Destructive
Ambient temp.
Humidity
4
6
Min. 100 M at 500 V DC
500 Vrms
1,000 Vrms
500 Vrms
Approx. 6 ms [Approx. 5ms]
3
Approx. 3 ms [Approx. 5ms]
Max. 60°Cwith nominal coil voltage across coil and at nominal switching capacity
2
Min. 196 m/s
5
Min. 980 m/s2 {100 G}
at double amplitude of 3 mm
at double amplitude of 5 mm
10 to 55 Hz
10 to 55 Hz
–40°C to 60°C
–40°F to 140°F
5 to 85% R.H.
Approx. 4.4 g .155 oz
{20 G}
TYPICAL APPLICATIONS
• Audio visual equipment broadcast satellite tuners VCRs, CATVs, TVs
• Communication equipment automobile telephones maritime telephones
• Instrumentation test equipment measuring equipment
ORDERING INFORMATION
101
Page 2
RK
TYPES ANE COIL DATA (at 20°C 68°F)
• Single side stable type
Part No.
voltage, V DC
Nominal
RK1-3V 3 2.25 0.3 45 66.7
RK1R-3V RK1-4.5V 4.5 3.38 0.45 101 44.4 4.95RK1R-4.5V RK1-5V RK1-6V RK1-9V RK1-12V
RK1R-5V
RK1R-6V
RK1R-9V
RK1R-12V
RK1R-24V
12 9 1.2 720 16.7 200 13.2 24 18 2.4 2,880 8.3 200 26.4RK1-24V
Pick-up voltage, max. V DC
Drop-out voltage, min. V DC
Coil resistance, (±10%)
Nominal operating current, mA
Nominal operating power, mW
200
200 5 3.75 0.5 125 40.7 200 5.5 6 4.5 0.6 180 33.3 200 6.6 9 6.75 0.9 405 22.2 200 9.9
• 1 coil latching type
Nominal
Part No.
voltage, V DC
RK1-L-3V 3 2.25 2.25 45 66.7
RK1R-L-3V RK1-L-4.5V 4.5 3.38 3.38 101 44.4 RK1-L-5V RK1-L-6V RK1-L-9V RK1-L-12V
RK1R-L-5V
RK1R-L-6V
RK1R-L-9V
RK1R-L-12V
RK1R-L-24V
12 9 9 720 16.7 200 13.2 24 18 18
Set voltage, max. V DC
Reset voltage, max. V DC
Coil resistance, (±10%)
Nominal operating current, mA
Nominal operating power, mW
200
200 5 3.75 3.75 125 40 200 5.5 6 4.5 4.5 180 33.3 200 6.6 9 6.75 6.75 405 22.2 200 9.9
2,880 8.3 200 26.4RK1-L-24V
• 2 coil latching type
Part No.
voltage, V DC
Nominal
RK1-L2-3V 3 2.25 22.5 133.3 400 3.3
RK1-L2-5V RK1-L2-6V RK1-L2-9V RK1-L2-12V
RK1R-L2-3V
RK1R-L2-5V RK1R-L2-6V RK1R-L2-9V RK1R-L2-12V RK1R-L2-24V
12 9 360 33.3 24 18 1,440 16.7 400 26.4RK1-L2-24V
DIMENSIONS
Set voltage, max. V DC
5 3.75 62.5 80 6 4.5 90 66.7 9 6.75 202.5 44.4
PC board pattern (Copper-side view) Schematic (Bottom view)
Reset voltage, max. V DC
2.25
3.38RK1-L2-4.5V 4.5 3.38 50.6 88.9 400 4.95RK1R-L2-4.5V
3.75
4.5
6.75 9
18
Coil resistance, (±10%)
Nominal operating current, mA
Nominal operating power, mW
400
400
400
400
Maximum. allowable voltage, V DC (at 60°C 140°F)
Maximum. allowable voltage, V DC (at 60°C 140°F)
Maximum. allowable voltage, V DC (at 60°C 140°F)
3.3
3.3
4.95RK1R-L-4.5V
5.5
6.6
9.9
13.2
mm inch
20.2
.795
2.54
.100
(Single side stable and 1 coil latching)
3-0.45
3-.018
(2 coil latching)
3-0.45
3-.018
3.5
.138
9.1
.358
0.6
.024
4-0.6×0.25
4-.024×.010
4-0.6×0.25
4-.024×.010
11.2
.441
7.62
.300
2-0.6×0.3
2-.024×.012
Stand-off
3-0.6×0.3
3-.024×.012
Stand-off
(Single side stable and 1 coil latching)
9-0.9 dia.
9-.035 dia.
2.54
.100
7.62
.300
2.54
.100
(2 coil latching)
10-0.9 dia.
10-.035 dia.
2.54
.100
7.62
.300
2.54
.100
Tolerance: ±0.1 ±.003
Standard contact arrangement
RK1
1
+
Single side
7
stable (Deenergized
14
13 12 11 10 9 8
N.C. COM N.O.
condition)
RK1-L
+
1
7
1 coil latching (Reset
14
13 12 11 10 9 8
RESET COM SET
condition)
RK1-L2
2 coil
17
14
13 12 11 10 9 8
RESET COM SET
6
latching
+–+
(Reset condition)
R type contact arrangement
RK1R
1
14
13 12 11 10 9 8
N.O. COM N.C.
+
RK1R-L
+
1
14
13 12 11 10 9 8
SET COM RESET
RK1R-L2
17
14
13 12 11 10 9 8
SET COM RESET
6
+–+
7
7
102
General tolerance: ±0.3 ±.012
Page 3
REFERENCE DATA
1.-(1) High frequency characteristics (Impedance 75 Ω )
Sample: RK1-12V Measuring method: Measured with HP network analyzer (HP8753C)
• Insertion loss characteristics • Isolation characteristics • V.S.W.R. characteristics
0
COM-NO
0
2.0
RK
0.2
0.4
Insertion loss, dB
0.6
0.8
1.0 300kHz 1.5GHz 3GHz
COM-NC
Frequency
20
40
Isolation, dB
60
80
100
300kHz 1.5GHz 3GHz
COM-NO
COM-NC
Frequency
1.8
1.6
V.S.W.R.
1.4
1.2
1.0 300kHz 1.5GHz 3GHz
1.-(2) High frequency characteristics (Impedance 50 Ω )
Sample: RK1-5V Measuring method: Measured with HP network analyzer (HP8753C)
• Insertion loss characteristics • Isolation characteristics • V.S.W.R. characteristics
0
0.2
0.4
Insertion loss, dB
0.6
0.8
COM-NO
COM-NC
0
20
40
Isolation, dB
60
80
COM-NO
COM-NC
2.0
1.8
1.6
V.S.W.R.
1.4
1.2
COM-NC
COM-NO
COM-NC
Frequency
COM-NO
1.0 300kHz 1.5GHz 3GHz
Frequency
2. Coil temperature rise
Sample: RK1-12V, RK1-L-12V, RK1-L2-12V No. of samples: n = 6 Carrying current: 10 mA Ambient temperature: 25°C 77°F
100
80
60
40
Temperature rise, °C
20
0
80 100 130 150
Voltage applied to coil, %V
RK1-L2-12V
RK1-12V, RK1-L-12V
100
300kHz 1.5GHz 3GHz
Frequency
3.-(1) Operate/Release time (Single side stable)
Sample: RK1-12V; No. of samples: n = 6
10
8
Operate time
6
4
Operate/Reset time, ms
2
0
80 100 120 150
Release time
Voltage applied to coil, %V
Max. Min. Max.
Min.
1.0 300kHz 1.5GHz 3GHz
Frequency
3.-(2) Set/Reset time (Latching)
Sample: RK1-L-12V, RK1-L2-12V No. of samples: n = 12
10
8
6
4
Set/Reset time, ms
2
0
80 100 130
Voltage applied to the coil (%V)
Set time Reset time
Max. Max. Min. Min.
103
Page 4
RK
4.-(1) Mechanical life test (Single side stable)
Sample: RK1-12V; No. of samples: n = 12
12
4.-(2) Mechanical life test (Latching)
Sample: RK1-L2-12V No. of samples: n = 12
12
4.-(3) Mechanical life test
Sample: RK1-12V No. of samples: n = 20 (20 × 2 contacts)
300
10
8
6
4
Pick-up/drop-out voltage, V
2
0
Pick-up voltage
Drop-out voltage
100 500 1,000
No. of operations, ×10
5. Electrical life test (0.01 A 24 V DC)
Sample: RK1-12V; No. of samples: n = 6
12
10
8
6
4
Pick-up/drop-out voltage, V
2
0
Pick-up voltage
Drop-out voltage
10 20 30
No. of operations, ×10
10
Max. Min.
Max.
Min.
4
8
6
Set/Reset voltage, V
4
2
0
100 500 1,000
No. of operations, ×10
Max. Min.
4
6. Ambient temperature characteristics
Sample: RK1-12V; No. of samples: n = 6
250
200
150
Contact resistance, m
100
50
0
50 100 500 1,000
No. of operations, ×10
4
7. Contact resistance distribution (initial)
Sample: RK1-12V
Max.
Min.
No. of samples: n = 50 (50 × 2 contacts)
40
Pick-up voltage
Max. Min.
–40
–20–40
–40
Max. Min.
4
20
Drop-out voltage
Rate of change, %
40
20
68
1046014080176
Ambient temperature,
–20
°C °F
–40
50
40
Quantity
30
20
10
0
10 20 30 40 50
Contact resistance, m
8.-(1) Influence of adjacent mounting
Sample: RK1-12V; No. of sample: n = 10
10
0
–10
10
0
–10
Rate of change, % Rate of change, %
Inter-relay distance, (mm, inch)
Pick-up voltage
Drop-out voltage
5
OFF OFF
OFF condition
ON ON
ON condition
10
NOTES
1. Soldering
Perform soldering under the conditions below.
• Within 10 s at 260°C 500°F
• Within 3 s at 350°C 662°F
8.-(2) Influence of adjacent mounting
Sample: RK1-12V; No. of samples: n = 10
10
10
0
0
–10
10
0
–10
Rate of change, % Rate of change, %
Inter-relay distance, (mm, inch)
Pick-up voltage
Drop-out voltage
5
OFF
OFF
OFF condition
ON
ON
ON condition
10
2. Latching relay
In order to assure proper operating re­gardless of changes in the ambient usage temperature and usage conditions, nomi­nal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
104
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.