Contact arrangement 1, 2, 3, 4, 6 and 8 form C (CO)
Rated voltage 120VAC
Rated current 7.5A
Contact material Ag, AgCdO, Au overlay Ag, AuPtAg
Contact style Single or bifurcated crossbar
Min. recommended contact load
W type, AgCdO, single contact 300mA, 12VDC
X type, AgCdO, single contact 300mA, 12VDC
M type, AgCdO, bifurcated contact 300mA, 12VDC
Y type, Ag, single contact 100mA, 12VDC
Z type, Ag, bifurcated crossbar 1mA, 12VDC
P type, Au overlay Ag, bifurcated crossbar dry circuit
L type, AuPtAg, bifurcated crossbar dry circuit
Initial contact resistance
All AgCdO contact types 100mΩ
All other contact materials and types 50mΩ
Frequency of operation 360 ops./hr
Contact ratings
Type Load Cycles
UL 508
W type, AgCdO, single contact
7.5A, 120VAC, resistive
7.5A, 28VDC, resistive
1/8HP, 120VAC, same polarity
1/6HP, 240VAC, same polarity
X type, AgCdO, single contact
2A, 30VDC, resistive 100x103
5A, 120VAC, resistive 6x103
5A, 30VDC, resistive 100x103
1/20HP, 120VAC, same polarity
1/10HP, 240VAC, same polarity
M type, AgCdO, bifurcated contact
5A, 120VAC, resistive 6x103
5A, 28VDC, resistive 6x10
Y type, Ag, single contact
2A, 120VAC 6x103
2A, 28VDC 6x103
250VA, 250VAC 30x103
125VA, 125VAC 100x10
Z type, Ag, bifurcated crossbar contact
3A, 120VAC 6x103
3A, 28VDC 6x103
2A, 30VDC 100x103
R10 R10-R R10S R10-T
Contact ratings (continued)
Type Load Cycles
UL 508
P type, Au overlay Ag, bifurcated crossbar contact
2A, 120VAC, resistive 100x103
3 A, 120 VAC, resistive 6x103
3 A, 30 VDC, resistive 100x103
L type, AuPtAg, bifurcated crossbar contact
500mA, 28VDC, resistive 6x103
Mechanical endurance 10x106 ops., except W type is 1x106 ops.
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
1
tion, application notes and all specifications
are subject to change.
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
3
tion, application notes and all specifications
are subject to change.
Page 4
1.187 MAX.
NIB .091 DIA.
t
SIDE ONLY
14
1 POLE
8 9
10
2 POLE
3 POLE
4 POLE
6 POLE
8 POLE
1
28 15 16
COIL
Signal
Signal Relays
R10 Series Relay (Continued)
Potter & Brumfield
Insulation Data
Initial dielectric strength
between open contacts 500V
between contact and coil 1000V
between adjacent contacts 1000V
Initial insulation resistance
rms
rms
rms
between insulated elements 10GΩ, 500VDC
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature -55ºC to 75ºC
Category of environmental protection
IEC 61810 RTI - dust protected and RTIII - wash tight
Dimensions
(30.15)
R10S: 1.50 MAX.
(38.1)
2 POLE .950 MAX.
(24.13, 2 POLE 1R10)
4 POLE 1.165 MAX.
(29.59, 4 POLE 1R10)
6 POLE 1. 375 MAX.
(34.93)
8 POLE 1. 580 MAX.
(40.13)
.375
(9.53)
#6-32
THREAD
.156
(3.96)
TYPE E6 ONLY
(10.31)
3-48 THREAD
x .020 HIGH
(2.31) (.51)
.406
.735 MAX.
(18.67)
TYPE E1 ONLY
}
.135
(3.43)
.354
(8.99)
CASE E
ONLY
.085 MAX.
(2.16)
.171
(4.43)
.210
(5.33)
Other Data (continued)
Terminal type Solder/plug-in terminals, PCB-THT,
8- or 11-PIN octal type plug
Weight 23 to 40g
Packaging/unit tray/50 pcs., box/350pcs.
Accessories
For details see datasheet Sockets and Accessories, R10 Relays
Product Code Description
Many versions of sockets and clips available.
NOTE: Relays with contact current <50mA are not recommended for use in sockets.
CASE R ONLY
Recommend tape tab
be removed after
immersion cleaning
and before relay is pu
in service. Peel off to
permit proper relay
ventilation.
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Page 5
(8
(18.80)
- .00
( )
.500
(11.43)
(2.54)
- .00
.056
5
.38)
2 HOLES
(1
(25.40 ± .51)
.187 ± .0 02 DIA.
A.
(3.73 ± .05)
Signal
Signal Relays
Potter & Brumfield
R10 Series Relay (Continued)
PCB layout Suggested panel cutout for relay Mounting hole layout for
Bottom view on solder pins terminal & mounting style 6
R10 Cradle-style relay with form C contacts R10S Super sensitive cradle-style relay with form C contacts
Case style
E Non-sealed polycarbonate dust cover (RTI) R Wash-tight (RTIII), tape sealed plastic case 1) T Octal style base on non-sealed polycarbonate dust cover (terminal types 1 & 2 only; 1, 2 & 3 poles only)
1) R10 type only, terminal code 2 or 9 only, no ground or stud
Terminal and mounting
1 Solder/Plug-in terminals with #3-48 mounting stud on R10-E; 8-pin octal type on R10-T
2 PCB terminals (std.) 1.62mm (.064in) clearance, 31.75mm (1.25in) seated ht.; 11-pin octal type on R10-T
6 Side mounting plate with #6-32 stud, solder/plug-in terminals (#3-48 stud not included)
7 Narrow 1.02mm (.04in) PCB terminals, .33mm (.013in) clearance, 30.48mm (1.2in) seated ht.
9 Non-shouldered, narrow 1.02mm (.04in) PCB terminals in staggered arrangement
2) Available only on 1 through 6 pole models
Contact style and rating
W Single contact rated 7.5A max, 300mA min.
X Single contact rated 5A max, 300mA min.
M Bifurcated contact rated 5A max, 300 mA min.
3)
4) 5)
5) 6)
5) 6)
Y Single contact rated 2A typ, 3A max, 100mA min. Z Bifurcated low level contacts rated 100mA typ, 2A max, 1mA min.
P Bifurcated crossbar dry circuit contacts rated 1mA typ, 3A max, dry circuit min.
L Bifurcated crossbar dry circuit contacts rated 500 microA typ, 250 mA max, dry circuit min.
3) Ratings are at 28VDCV or 115VAC. Total load must not exceed 30A per relay.
4) Use ungrounded frame for AC load of ≥5A. Max ratings are 7.5A at 115VAC and 4A at 28VDC for coil codes S & J
5) Only available on R10 type, only available with coil adjustment code V, Q, S and J.
6) Use ungrounded frame for AC load of ≥5A. Max ratings are 5A at 115VAC and 3A at 28VDC for coil codes S & J
Number of poles
1 1 pole 4 4 pole (not available on R10-T)
2 2 pole 6 6 pole (not available on R10-T)
3 3 pole 8 8 pole (not available on R10-T)
7) Not available with contact code W
8) Only available with case style E, not available with contact code W
Coil voltage
Coil code: please refer to coil versions table
AC voltage Specify coil code consisting of nominal coil voltage followed by W (example: 24V) DC voltage Specify coil code consisting of coil adjustment code letter followed by coil resistance (example: V700)
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
2)
7)
8)
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
5
Page 6
Signal
Signal Relays
Potter & Brumfield
R10 Series Relay (Continued)
Product Code Arrangement Material Contact Style/Rating Nom. Coil VTerminals & MountingPart Number
R10-E1P2-115V2 form C, 2 CO Au overlay AgBif crossbar / dry circuit115 VACSolder/plug-in w/ #3-48 mounting stud7-1393765-0
R10-E1P2-V70024 VDC6-1393765-9
R10-E1P4-115V4 form C, 4 CO115 VAC7-1393765-6
R10-E1P4-V70024 VDC7-1393765-5
R10-E1W2-V1852 form C, 2 CO AgCdOSingle contact / 7.5A12 VDC8-1393765-9
R10-E1W2-V70024 VDC9-1393765-1
R10-E1W4-V1854 form C, 4 CO12 VDC9-1393765-3
R10-E1W4-V70024 VDC9-1393765-5
R10-E1X2-24V2 form C, 2 CO Single contact / 5A24 VAC1-1393766-1
R10-E1X2-115V115 VAC1-1393766-0
R10-E1X2-S80012 VDC1393766-3
R10-E1X2-V1851393766-5
R10-E1X2-V70024 VDC1393766-9
R10-E1X4-115V4 form C, 4 CO115 VAC1-1393766-8
R10-E1X4-V18512 VDC1-1393766-4
R10-E1X4-V70024 VDC1-1393766-7
R10-E1X4-V2.5K48 VDC1-1393766-5
R10-E1X6-115V6 form C, 6 CO115 VAC2-1393766-5
R10-E1X6-V9012 VDC2-1393766-4
R10-E1X6-V43024 VDC2-1393766-2
R10-E1Y2-J1.0K2 form C, 2 CO AgSingle contact / 2A typical Not applicable3-1393766-3
R10-E1Y2-J2.5K3-1393766-4
R10-E1Y2-V18512 VDC4-1393766-0
R10-E1Y2-V70024 VDC4-1393766-4
R10-E1Y2-V2.5K48 VDC4-1393766-1
R10-E1Y2-V15.0K115 VDC3-1393766-9
R10-E1Y4-J10.0K 4 form C, 4 CONot applicable4-1393766-9
R10-E1Y4-V526 VDC5-1393766-6
R10-E1Y4-V2.5K48 VDC5-1393766-5
R10-E1Y4-V70024 VDC5-1393766-7
R10-E1Y6-V4306 form C, 6 CO6-1393766-1
R10-E1Y6-V1.5K48 VDC6-1393766-0
R10-E1Z2-V1852 form C, 2 CO Bifurcated / 100mA typical12 VDC7-1393766-2
R10-E1Z2-V70024 VDC7-1393766-4
R10-E1Z4-V1854 form C, 4 CO12 VDC7-1393766-9
R10-E1Z4-V70024 VDC8-1393766-1
R10-E1Z4-V2.5K48 VDC8-1393766-0
R10-E1Z6-V4306 form C, 6 CO24 VDC8-1393766-6
R10-E1Z6-V1.5K48 VDC8-1393766-5
R10-T1P2-115V2 form C, 2 CO Au overlay AgBif crossbar / dry circuit115 VAC2-1393769-8
R10S-E1Y1-J1.0K 1 form C, 1 COAgSingle contact / 2A typical Not applicable7-1393769-0
R10S-E1Y2-J5.0K 2 form C, 2 CO 7-1393769-5
R10-E2P4-V1854 form C, 4 CO Au overlay AgBif crossbar / dry circuit12 VDCPCB, .064" clearance, 1.25" seated ht.1393767-3
R10-E2P4-V70024 VDC1393767-4
R10-E2W2-V1852 form C, 2 CO AgCdOSingle contact / 5A12 VDC1393767-7
R10-E2X2-V1851-1393767-1
R10-E2X2-V70024 VDC1-1393767-5
R10-E2X4-V1854 form C, 4 CO12 VDC1-1393767-7
R10-E2X4-V70024 VDC1-1393767-8
R10-E2Y2-V1852 form C, 2 CO AgSingle contact / 2A typical12 VDC2-1393767-6
R10-E2Y2-V70024 VDC2-1393767-9
R10-E2Y4-V1854 form C, 4 CO12 VDC3-1393767-5
R10-E2Y4-V70024 VDC3-1393767-6
R10S-E2Y1-J1.0K 1 form C, 1 CONot applicable8-1393769-1
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Loading...