Datasheet PR18-5DP2, PRL18-5DP, PRL18-5DN, PR18-5DP, PR18-5DN Specification

...
Page 1
INDUCTIVE PROXIMITY SENSOR
CYLINDRICAL TYPE DC 3WIRE
M A N U A L
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.
▣ Caution for your safety
※Please keep these instructions and review them before using this unit.
Please observe the cautions that follow;
Serious injury may result if instructions are not followed.
Warning Caution
※The following is an explanation of the symbols used in the operation manual. Caution:Injury or danger may occur under special conditions.
Warning
1. In case of using this unit with machineries(Nuclear power control, medical equipment vehicle, train, airplane, combustion apparatus, entertainment or safety device etc), it requires installing fail-safe device, or contact us for information on type required.
It may result in serious damage, fire or human injury.
Caution
1.
Do not use this unit in place where there are flammable, explosive gas, chemical or strong alkalis, acids.
It may cause a fire or explosion.
2. Do not impact on this unit.
It may result in malfunction or damage to the product.
3. Do not apply AC power and observe specification rating.
It may result in serious damage to the product.
▣ Ordering information
P R L L
Shape
Item
▣ Control output diagram & Load operating
NPN
Output
PNP
Output
Product may be damaged, or injury may result if instructions are not followed.
Output
Brown
Black
Blue
Brown
Black
Blue
V
Cable type
Load
Load
Standard cable
V
Oil resistant cable
S
Option
DN
DN2
DP2
NPN N.O.(Normally Open) NPN N.C.(Normally Closed)
DP
PNP N.O.(Normally Open) PNP N.C.(Normally Closed)
Number Unit: mm
Number Diameter of head(mm)
Standard
S
Short body
L
Long body
DC 3 wire, cable outgoing type
W
DC 3 wire, cable outgoing connector type
R Cylindrical type
P Inductive proximity sensor
Normally Open Normally Closed
Sensing
+V
0V
target
Load
(Brown-Black)
Output voltage
(Black-Blue)
Indicator
(LED)
Presence
Nothing
Operation
Return
ON
OFF
H
L
Normally Open Normally Closed
+V
0V
Sensing
target
Load
(Black-Blue)
Output voltage
(Black-Blue)
Indicator
(LED)
Presence
Nothing
Operation
Return
ON
OFF
H
L
Presence
Nothing
Operation
Return
ON
OFF
Presence
Nothing
Operation
Return
ON
OFF
518
DN
Standard sensing distance
Dimension
Body size
Connection
10㏀
Main circuit
10㏀
Main circuit
※ The a bove spec ifications are subje ct to chang e without notice.
H
L
H
L
▣ Specifications
PR08-1.5DN PR08-1.5DP PR08-1.5DN2 PR08-1.5DP2 PRL08-1.5DN PRL08-1.5DP PRL08-1.5DN2 PRL08-1.5DP2
Model
Sensing distance Hysteresis Standard sensing
target Setting distance Power supply
(Operating voltage) Current consumption Response frequency Residual voltage Affection by Temp. Control output Insulation resistance Dielectric strength Vibration Shock Indicator
Ambient temperature
Ambient humidity
Environment Protection circuit Protection
Materials
Approval
Unit weight
※ Condition for use in Environment is no freezing or condensation.
PRW08-1.5DN PRW08-1.5DP PRW08-1.5DN2 PRW08-1.5DP2 PRW08-1.5DN PRW08-1.5DP PRWL08-1.5DN PRWL08-1.5DP PRWL08-1.5DN2 PRWL08-1.5DP2
1.5㎜±10% 2㎜±10% 2㎜±10% 4㎜±10% 5㎜±10% 8㎜±10% 10㎜±10% 15㎜±10%
0~1.05㎜ 0~1.4㎜ 0~2.8㎜ 0~3.5㎜ 0~5.6㎜ 0~7㎜ 0~10.5㎜
PR:Approx. 68g PRL:Approx. 70g PRW:Approx. 30g PRWL:Approx. 32g
PR08-2DN PR08-2DP PR08-2DN2 PR08-2DP2 PRL08-2DN PRL08-2DP PRL08-2DN2 PRL08-2DP2 PRW08-2DN PRW08-2DP PRW08-2DN2 PRW08-2DP2
-V
PRW08-2DN
-V
PRW08-2DP PRWL08-2DN PRWL08-2DP PRWL08-2DN2 PRWL08-2DP2
8×8×1㎜
(Iron)
1.5k㎐ 1k㎐ 1.5k㎐ 500㎐ 500㎐ 350㎐ 400㎐ 200㎐ Max. 2.0V Max. 1.5V
Within ±10℃ max. of sensing distance at 20℃ in temperature range of -25 ~70℃(PR□08 Series: Max. ±20%)
Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: Heat-resistant ABS,
Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chloride(PVC)
PR12-2DN PR12-2DP PR12-2DN2 PR12-2DP2 PRS12-2DN PRS12-2DP PRS12-2DN2 PRW12-2DN PRW12-2DP PRW12-2DN2
-V PRW12-2DP2
-V PRL12-2DN
PRL12-2DP
1㎜ amplitude at frequency of 10 ~ 55㎐ in each of X, Y, Z directions for 2 hours
Surge protection, Reverse polarity proteciton, Overload & short circuit protection
PR:Approx. 70g PRS:Approx. 68g PRW:Approx. 40g PRL:Approx. 72g
PR12-4DN PR12-4DP PR12-4DN2 PR12-4DP2 PRS12-4DN PRS12-4DP PRS12-4DN2 PRW12-4DN PRW12-4DP PRW12-4DN2 PRW12-4DP2 PRL12-4DN PRL12-4DP
Max. 10% of sensing distance
12×12×1㎜
(Iron)
Min. 50㏁(500VDC megger)
1,500VAC 50/60㎐ for 1minute
500㎨(50G) X, Y, Z directions for 3 times
Operating indicator(Red LED)
-25 ~ 70℃,
35 ~ 95%RH,
PR18-5DN PR18-5DP PR18-5DN2 PR18-5DP2 PRL18-5DN PRL18-5DP PRL18-5DN2 PRL18-5DP2 PRW18-5DN PRW18-5DP PRW18-5DN2 PRW18-5DP2 PRWL18-5DN PRWL18-5DP PRWL18-5DN2 PRWL18-5DP2
18×18×1㎜(
12-24VDC
(10-30VDC)
Max. 10mA
Max. 200mA
Storage:
-30 ~ 80℃
Storage:
35 ~ 95%RH
IP67(IEC Standards)
PR:Approx. 119g PRL:Approx. 149g PRW:Approx. 84g PRWL:
Approx.
PR18-8DN PR18-8DP PR18-8DN2 PR18-8DP2 PRL18-8DN PRL18-8DP PRL18-8DN2 PRL18-8DP2 PRW18-8DN PRW18-8DP PRW18-8DN2 PRW18-8DP2 PRWL18-8DN PRWL18-8DP PRWL18-8DN2 PRWL18-8DP2
Iron
) 25×25×1㎜(
PR:Approx. 118g PRL:Approx. 142g PRW:Approx. 84g
108g
PRWL:
Approx.
PR30-10DN PR30-10DP PR30-10DN2 PR30-10DP2 PRL30-10DN PRL30-10DP PRL30-10DN2 PRL30-10DP2 PRW30-10DN PRW30-10DP PRW30-10DN2 PRW30-10DP2 PRW30-10DN-V PRW30-10DP-V PRWL30-10DN PRWL30-10DP PRWL PRWL
Iron
) 30×30×1㎜(
PR:Approx. 184g PRL:Approx. 222g PRW:Approx. 143g
108g
PRWL:
30-10 30-10
Approx.
DN2 DP2
▣ Dimensions
Type
Flush
Non-
flush
Flush
Non­flush
"F" type standard:
※"H" type
: ø3.5, 3 cores(Conductor cross section: 0.2㎟, Insulator diameter:ø1) and ø4, 3 cores/ø5, 3 cores(Conductor cross section: 0.3㎟, Insulator diameter:ø1.25)
Cable outgoing type Cable outgoing connector type
M8, M12, M18, M30 M8, M12, M18, M30
B
C
C
E
Type A B C D E F G H J K
PR M8×1 30 30 4 PRL M8×1 40 40 4
M8
PRW M8×1 30 30 4 PRWL M8×1 40 40 4 PR M12×1 46 31.5 4 PRS M12×1 39 24.5 4
M12
PRW M12×1 46 31 .5 4 PRL M12×1 5 8.5 44 4 PR M18×1 47. 5 2 9.5 4 PRL M18×1 8 0.5 62 4
M18
PRW M18×1 4 7.5 29.5 4 PRWL M18×1 8 0.5 62 4 PR M30×1.5 58 38 5 PRL M30×1.5 80 60 5
M30
PRW M30×1.5 58 38 5 PRWL M30×1.5 80 60 5 PR M8×1 30 30 4 4 2,000 PRL M8×1 40 40 4 4 2,000
M8
PRW M8×1 30 30 4 4 300 43.5 4 13 15 PRWL M8×1 40 40 4 4 300 43.5 4 13 15 PR M12×1 46 31.5 4 7 2,000 PRS M12×1 39 24.5 4 7 2,000
M12
PRW M12×1 46 31 .5 4 7 300 43.5 4 17 21 PRL M12×1 5 8.5 37 4 7 2,000 43.5 4 17 21 PR M18×1 47 29 4 1 0 2,000 PRL M18×1 80 62 4 10 2,000
M18
PRW M18×1 47 29 4 10 3 00 43.5 5 24 29 PRWL M18×1 80 62 4 10 300 43.5 5 24 29 PR M30×1.5 58 38 5 1 0 2,000 PRL M30×1.5 80 60 5 10 2,000
M30
PRW M30×1.5 58 38 5 10 300 43.5 5 35 42 PRWL M30×1.5 80 60 5 10 300 43.5 5 35 42
Cable outgoing type/2,000㎜, Cable outgoing connector type/300㎜
※F
※H
A
D
B
※F
※H
A
D
B
C
A
D
B
C
E
AD
※F
※H
※F
※H
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
G
M12×1
G
M12×1
2,000 2,000
2,000 2,000
2,000 43.5 4 1 7 21 2,000 2,000
2,000 2,000
-
3.5 13 15
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.5 13 15
4 17 21 4 1 7 21
5 2 4 29 5 2 4 29
5 3 5 42 5 3 5 42
3.5 13 15
3.5 13 15
4 17 21 4 1 7 21
5 2 4 29 5 2 4 29
5 3 5 42 5 3 5 42
300 43.5 4 13 15 300 43.5 4 13 15
300 43.5 4 17 21
300 43.5 5 24 29 300 43.5 5 24 29
300 43.5 5 35 42 300 43.5 5 35 42
▣ Connections
NPN PNP
Connector
2 1 3
4
Brown
Black Blue
+V
Load
0V
Brown
2
1
Black
4
3
Blue
Load
PR30-15DN PR30-15DP PR30-15DN2 PR30-15DP2 PRL30-15DN PRL30-15DP PRL30-15DN2 PRL30-15DP2 PRW30-15DN PRW30-15DP PRW30-15DN2 PRW30-15DP2 PRW30-15DN-V PRW30-15DP-V PRWL30-15DN PRWL30-15DP PRWL
30-15
PRWL
30-15
Iron
) 45×45×1㎜(
PR:Approx. 181g PRL:Approx. 227g PRW:Approx. 143g
178g
PRWL:
Approx.
(Unit:mm)
Nut & Washer
K
J
+V
0V
◎Mutual-interference
When several proximity sensors are mounted closely, malfunction of sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors with referring to the chart below.
Face to Face Parallel
B
A
◎Influence by surrounding metals
When sensors are mounted on metallic panel, it is required to protect the sensors from being affected by any metallic object
DN2 DP2
Iron
except target. Therefore, be sure to provide a minimum distance as below chart.
)
Model
PR□08-1.5D□ PR□08-2D□ PR□12-2D□ PR□12-4D□
Item
A 9 12 12 24 30 48 60 90
ød
PR□18-5D□ PRW□18-5D□
PR□18-8D□ PRW□18-8D□
PR□30-10D□ PRW□30-10D□
m
n
B 16 24 24 36 36 54 60 90
0 8 0 11 0 14 0 15
ød 8 24 12 36 18 54 30 90
m 4.5 6 6 12 15 24 30 45
n 12 24 18 36 27 54 45 90
▣ Setting distance
Sensing distance can be changed by the shape, size or material of the target. Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa).
Setting distance(Sa) = Sensing distance(Sn) × 70% Ex)PR30-10DN(See ordering information) Setting distance(Sa) = 10mm × 0.7 = 7mm
178g
Moving
direction
(a)
Target
Moving
direction
Sn:
Sensing distance
{
Sa:
Setting distance (70% of Sn)
Target
Sn
Sa
(b)
▣ Caution for using
1. This equipment shall not be used outdoors or beyond specified temperature range.
2. Do not apply over tensile strength of cord. (ø4: 30N max., ø5: 50N max.)
3. Do not use the same conduit with cord of this unit and electric power line or power line.
4. Do not put overload to tighten nut, please use the supplied washer for tightening.
Strength
Head
Rear
Front
[Picture 1]
Note1)Allowable tightening torque of a nut may be different by the distance from the head. For allowable tightening torque and the range
of front and rear parts, refer to [Table 1] and above [Picture 1] respectively. The rear part includes a nut on the head side(see above [Picture 1]). Please apply a tightening torque of the front part when the nut on the front is located in the front part.
Note2) The allowable tightening torque denotes a torque value when using a provided washer as above [Picture 2].
5
. Please check the voltage changes of power source in order not to excess rating power input.
6. Do not use this unit during transient time(80ms) after apply power.
7. It might result in damage to this product, if use automatic transformer. So please use insulated transformer.
8. Please make wire as short as possible in order to avoid noise.
9. Be sure to use cable as indicated specification on this product. If wrong cable or bended cable is used, it shall not maintain the water-proof.
10. It is possible to extend cable with over 0.3mm2 and max. 200m.
11. If the target is plated, the operating distance can be changed by the plating material.
12. It may result in malfunction by metal particle on product.
13. If there are machines(motor, welding etc), which occurs big surge around this unit, please install the varistor or absorber to source of
surge, even though there is built-in surge absorber in this unit.
14. If connecting the load with big inrush current(DC type bulb) to this unit, the big inrush current will flow since the initial resistance is low.
If the current flows, the resistance of load will be bigger, then it will return to standard current. In this case, proximity sensor might be damaged by inrush current.
If you use DC type bulb, please connect extra relay or resistance in order to protect proximity sensor from.
15. If making a transceiver close to proximity sensor or wire connection, it may cause malfunction.
washer
mounting
[Picture 2]
bracket
Model
PR08 Series
Non-flush 5mm
PR12 Series
Non-flush 7mm
PR18 Series
Non-flush -
PR30 Series
Non-flush 12mm
Flush 7mm
Flush 13mm
Flush -
Flush 26mm
Front Rear
Size Torque Torque
40kgf·cm
(3.92N·m)
65kgf·cm
(6.37N·m)
500kgf·cm
(49N·m)
[Table 1]
※It may cause malfunction if above instructions are not followed.
▣ Major products
■ Proximity sensors
■ Area sensors
■ Photoelectric sensors
■ Fiber optic sensors
■ Door/Door side sensors
■ Sensor controllers
■ Graphic/Logic panels
■ Temperature controllers
■ Tachometer/Pulse(Rate) meters
■ Temperature/Humidity transducers
■ Switching power supplies
■ Stepping motors/drivers/motion controllers
■ Field network devices
■ Laser marking system(CO₂, Nd:YAG)
■ Laser welding/soldering system
■ Counters
■ Timers
■ Display units
■ Panel meters
■ Pressure sensors
■ Rotary encoders
■ Power controllers
http://www.autonics.com
Satisfiable Partner For Factory Automation
■HEAD QUARTERS : 41-5. Yongdang-dong, Yangsan-si, Gyeongnam, 626-847,
Korea
■OVERSEAS SALES :
Bldg. 402 3rd FL., Bucheon Techno Park, 193, Yakdae-dong,
Wonmi-gu,
Bucheon-si, Gyeonggi-do, 420-734, Korea
TEL : 82-32-610-2730 / FAX : 82-32-329-0728
■E-mail : sales@autonics.com
The proposal of a product improvement
and development: product@autonics.com
EP-KE-07-0360G
PR□30-15D□ PRW□30-15D□
90kgf·cm
(8.82N·m)
120kgf·cm
(11.76N·m)
150kgf·cm
(14.7N·m)
800kgf·cm
(78.4N·m)
(Unit:mm)