1
PerFormanCe POWER PFC500
The PFC500 products of the PerFormanCe Power series combine high
performance midrange power with high power density (4.4 watts/in
3
),
active Power Factor Correction (PFC) and high reliability to meet the
requirements of commercial and industrial systems.
Providing tightly regulated DC power, the PFC500 is delivers full
output performance with only 300 Linear Feet per Minute (LFM)
forced air cooling (factory installed fan optional). Other features
include remote sense, power fail, logic level inhibit, DC power good.
Main channel current sharing is provided for redundant applications.
The PFC500 is available with SAE mountings or optional metric
mountings.
The PFC500 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Fully Regulated Outputs
• Remote Sense
• Current Share, Power Fail, and Power Good Signals
• Overtemperature, Overvoltage, and Overcurrent Protected
• Available with Metric or SAE Mountings
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
• Fan Output Voltage and Optional Fan
• Optional Isolation Diodes for Parallel or Redundant Operation
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC
Input Frequency AC Input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC
Hold-Up Time Over full AC input voltage range at full rated load. 20 mS
Input Current 85 VAC at full rated load. 7.8 ARMS
Input Protection Non-user serviceable internally located AC input line fuse, F10A, 250V.
Inrush Surge Current Internally limited by thermistor, one cycle, 25°C. 110 VAC 35
APK
220 VAC 65
Power Factor Per EN61000-3-2. 0.98 W/VA
Operating Frequency Switching frequency of main transformer. 100 kHz
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION (NOTE 3) %p-p (NOTE 2) ACCURACY
PFC500-1024 24V 21.6V to 26.4V 21A 0.5% 0.2% 1% 23.88V to 24.12V
PFC500-1028 28V 25.2V to 30.8V 17.9A 0.5% 0.2% 1% 27.86V to 28.14V
PFC500-1048 48V 46.0V to 56.0V 10.4A 0.5% 0.5% 1% 47.52V to 48.48V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3) Remote sense connected.
Rev. 04/2000