Datasheet PD30CND10NAM5SA, PD30CND10PAM5SA Specification

Page 1
Photoelectrics Diffuse-reflective
Type PD30CND10....SA
• Miniature sensor range
• Range: 1 m
• Sensitivity adjustment by Potentiometer
• Modulated, red light 625 nm
• Supply voltage: 10 to 30 VDC
• Output: 100 mA, NPN or PNP preset
• Make and break switching function
• LED indication for output, stability and power ON
• Protection: reverse polarity, short circuit and transients
• Cable and plug versions
• Excellent EMC performance
Product Description
The PD30CND10 sensor family comes in a compact 10 x 30 x 20 mm reinforced PMMA/ABS housing. The sensors are useful in applications where high-ac­curacy detection as well as small size is required. Compact housing and high power LED for excellent performance-size ratio.
The Potentiometer function for adjustment of the sen­sitivity makes the sensors highly flexible. The output type is preset (NPN or PNP), and the output switching function is NO and NC out­put.
Ordering Key
Type Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection type Sensitivity adjustment
PD30CND10NAM5SA
Type Selection
Housing Range Connection Ordering no. Ordering no. W x H x D Sn NPN PNP Make and break switching Make and break switching
10 x 30 x 20 mm 1000 mm Cable PD 30 CND 10 NASA PD 30 CND 10 PASA 10 x 30 x 20 mm 1000 mm Plug PD 30 CND 10 NAM5SA PD 30 CND 10 PAM5SA
Specifications EN 60947-5-2
Rated operating distance (Sn) Up to 1 m, reference target Kodak test card R27, white, 90% reflective, 200 x 200 mm
Blind zone ≤ 20 mm @ maximum distance
Sensitivity Electrical adjustment 210˚
Mechanical adjustment 240˚ Temperature drift ≤ 0.2%/ºC Hysteresis (H) 5% to 20% Rated operational volt. (UB ) 10 to 30 VDC
(ripple included)
Ripple (U Output current
Continuous (Ie) ≤ 100 mA Short-time (I) ≤ 100 mA (max. load capacity 100 nF)
No load supply current (Io) ≤ 25 mA @ UB max Minimum operational current (Im)
) ≤ 10%
rpp
≤ 0.5 mA
OFF-state current (Ir ) ≤ 100 µA Voltage drop (Ud ) ≤ 2 VDC @ Ie max Protection
and transients
Light source InGaAlP, LED, 625 nm Light type Red, modulated Emitter angle ± 2º @ half sensing
distance Light spot
1.5 times the sensing distance 110 mm
Ambient light ≤ 10,000 lux Operating frequency (f) ≤ 1000 Hz Response time
OFF-ON (tON) ≤ 0.5 ms ON-OFF (t
Power ON delay (tv) ≤ 30 ms Output function
Open collector NPN or PNP by sensor type Output switching function N.O. and N.C.
) ≤ 0.5 ms
OFF
Short-circuit, reverse polarity
Specifications are subject to change without notice (14.06.2016) 1
Page 2
PD30CND10....SA
Specifications (cont.)
Indication
Output ON LED, yellow Signal stability ON and
Power ON
LED, green. See curve for
condition of stability Environment
Installation category III (IEC 60664/60664A; 60947-1) Pollution degree 3 (IEC 60664/60664A; 60947-1) Degree of protection IP 67 (IEC 60529; 60947-1)
Ambient temperature Operating
-25° to +60°C (-13° to +140°F)
Storage -40° to +70°C (-40° to +158°F) Vibration 10 to 150 Hz, 1.0 mm/15 G
(IEC 60068-2-6) Shock 30 g / 11ms, 3 pos, 3 neg
per axis (IEC 60068-2-6, 60068-2-32)
Operation Diagram
Tv = Power ON delay
ON
Power supply
Object
Break Output (N.C.)
Make Output (N.O.)
OFF
Present Not Present
ON OFF
ON OFF
Tv
Rated insulation voltage ≤ 500 VAC (rms) Housing material
Body ABS Light Grey Frontglas PMMA Red Trimmer shaft POM Dark Grey
Connection Cable PVC, black, 2 m 4 x 0.14 mm2, Ø = 3.3 mm Plug M8, 4-pin (CON. 54-series)
Weight Cable version ≤ 50 g Plug version ≤ 20 g
CE-marking Yes Approvals cULus (UL508 + CSA)
Tv
Signal Stability Indication
Excess Gain
1.10
1.0
0.90
Green LED ON
Yellow LED ON
Operation level x 1.10
Operation level Operation level x 0.90
Time
Wiring Diagrams
NPN
PNP
1BN
2WH 4BK
3BU
1BN
4BK 2WH
3BU
2 Specifications are subject to change without notice (14.06.2016)
Page 3
PD30CND10....SA
PD30CNP 06NPM5T
R
L
U
xxxxxxS
10-30 V 100 mA
BN: V+ BU: V- BK: OUT WH: ET
PD30CNP 06NPM5T
R
L
U
xxxxxxS
10-30 V 100 mA
BN: V+ BU: V- BK: OUT WH: ET
> 100 mm
Incorrect
Correct
Sensor
Detection Diagram
Sender
Y
X
R27 Kodac test card
Distance (Inches)
0,0 7,9 15,7 23,6 31,5 39,4 47,2 55,1
50 40 30 20 10
0
(mm)
-10
-20
-30
-40
-50 0 200 400 600 800 1.000 1.200 1.400
Distance (mm)
Dimensions
Cable version
10.6
20
Output LED
Yellow
1.1
17
Receiver
Optical axis
Power / Stability LED Green
10.6
10.8
Two, 9.5 dia.
Lenses
2,0 1,6 1,2 0,8 0,4 0,0
-0,4
-0,8
-1,2
-1,6
-2,0
Potentiometer
Excess Gain
1.000
100
(Inches)
Excess Gain
1.1
7
Distance (Inches)
0,0 0,4 3,9 39,4 393,7
10
1
1 10 100 1.000 10.000
Distance (mm)
Plug version
10.6
20
Output LED
Yellow
17
Receiver
Optical axis
Power / Stability LED Green
10.6
10.8
Two, 9.5 dia.
Potentiometer
Lenses
1.000
100
10
1
7
5.55.5
Correct
Correct
> 100 mm
22
Emitter
30
25.4
Two M3
Installation Hints
To avoid interference from inductive voltage / current peaks, separate the proximity switch cables from any other power cables. E.g. Engine, contactor or solenoid cables
Incorrect
Delivery Contents
Photoelectric switch: PD30CND10 ...
Screwdriver
• Packaging: Plastic bag
5.55.5
30
25.4
15
Two M3
Relief of the cable strain Protection of the sensing face Sensor mounted on a mobile carrier
Incorrect
Incorrect
10.25
22
15
Emitter
Correct
The cable should not be pulled
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
Accessories
Mounting bracket APD30-MB1 or APD30-MB2 to be purchased separately.
Specifications are subject to change without notice (14.06.2016) 3
Loading...