PAC-95
05186
. . . engineered solutions for the transient environment™
AC POWER LINE TVS COMPONENT
APPLICATIONS
✔ AC Power Mains
✔ Module Lightning Protection
IEC COMPATIBILITY (EN61000-4)
✔ 61000-4-5 (Power): 8/20µs - 1kA, L4 (Line-Line), 333A, L4 (Line-Ground)
FEATURES
✔ 4784 to 6920 Kilowatts Peak Pulse Power per Line (8/20µs)
✔ Glass Passivated Chip
✔ Bidirectional Configuration
✔ Easy Mounting to Printed Circuit Boards
✔ Available in Voltage Types Ranging From: 90V to 240VAC
MECHANICAL CHARACTERISTICS
thru
PAC-240
RADIAL LEADS
✔ Epoxy Case
✔ Weight 7.2 - 11.3 grams (Approximate)
✔ Flammability Rating UL 94V-0
✔ Marking: Logo & Device Marking Code
90V
120V
240V
APPLICATION
AC POWER LINE PROTECTION
AC
AC
AC
05186.R0 1/03
1
www.protekdevices.com

DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PAC-95
thru
PAC-240
PARAMETER
Peak Pulse Power Dissipation (tp =8/20µs) - See Fig. 1
Storage Temperature
Operating Temperature
ELECTRICAL CHARACTERISTICS
PA RT
NUMBER
VOLTS AC
PAC-95
PAC-130
PAC-240
RATED
STAND-OFF
VOLTAGE
V
WM
95
130
240
V
WM
VOLTS DC
135
202
380
BREAKDOWN
VOLTAGE
MIN
V
(BR)
VOLTS DC
157
214
400
SYMBOL VALUE
PP
T
STG
J
MAXIMUM
LEAKAGE
CURRENT
@V
@I
mA
1
1
1
T
I
µA
20
20
20
WM
D
4784 & 6920P
-40 to +125
-40 to +125
MAXIMUM
CLAMPING
VOLTAGE
@ 8/20µs
VC @ I
299V @ 16kA
378V @ 16kA
692V @ 10kA
UNITS
kilowatts
0
C
0
CT
TEMPERATURE
COEFFICIENT
OF V
(BR)
θV
(BR)
PP
%/°C
0.1
0.1
0.1
2 www.protekdevices.com05186.R0 1/03

GRAPHS
PAC-95
thru
PAC-240
100,000
10,000
4784kW 8/20µs
Waveform
1000
- Peak Pulse Power - kilowatts
PP
P
100
0.1 1 10 100 1,000 10,000
FIGURE 2
120
PP
100
80
60
40
- Peak Pulse Current - % of I
20
PP
I
0
0 5 10 15 20 25 30
PULSE WAVE FORM
t
f
Peak Value I
-t
e
td = t
t - Time - µs
PP
IPP/2
TEST
WAVEFORM
PARAMETERS
tf = 8µs
td = 20µs
PEAK PULSE POWER VS PULSE TIME
FIGURE 1
6920kW 8/20µs
Waveform
t
- Pulse Duration - µs
d
POWER DERATING CURVE
FIGURE 3
100
80
60
40
% Of Rated Power
20
0
0 25 50 75 100 125 150
T
- Lead Temperature - °C
L
Peak Pulse Power
8/20µs
Average Power
3 www.protekdevices.com05186.R0 1/03

PACKAGE OUTLINE & DIMENSIONS
PAC-95
thru
PAC-240
90VAC RADIAL LEAD PACKAGE OUTLINE
A
E
B
F
C
D
130 & 240 VAC RADIAL LEAD PACKAGE OUTLINE
A
E
B
F
C
PACKAGE DIMENSIONS
(90 VAC Device)
MILLIMETERS
DIM (Nominal) (Nominal)
A
B
C
D
E
F
12.5
12.45
1.27
20.1
6.35
23.37
INCHES
0.49
0.49
0.05
0.79
0.25
0.92
PACKAGE DIMENSIONS
(130 & 240 VAC Devices)
MILLIMETERS
DIM (Nominal) (Nominal)
A
B
C
D
E
F
18.12
13.72
1.25
23.722 ±1.16
7.37
20.0
INCHES
0.69
0.54
0.049
0.934 ± 0.046
0.29
0.787
D
06041 Rev 0 - 2/03
ProTek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288
E-Mail: sales@protekdevices.com
COPYRIGHT © ProTek Devices 2003
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC).
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and
technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
4 www.protekdevices.com05186.R0 1/03
Web Site: www.protekdevices.com