OWT SERIES - TRIPLE OUTPUT, 25 WATT
DESCRIPTION
OWT triple output DC/DC converters provide up to
25 Watts of output power in an industry standard 2” x 2”
package. OWT units feature excellent efficiency, fivesided shielding, and fixed switching frequency. With
85°C case operation, the OWT is especially suited to
telecom, networking, and industrial applications.
TECHNICAL SPECIFICATIONS
Input
Voltage Range
12 VDC Nominal 10 - 20 VDC
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 20 - 60 (add -S1 to p/n) or 36 - 72 VDC
Input Ripple Current 20% Iin Max.
Reverse Input Current 100% Iin Max.
Output
Setpoint Accuracy, V
Line regulation Vin Min. - Vin Max., I
Load regulation I
Minimum Output Current 25 %
Dynamic Regulation, Loadstep 25% I
Pk Deviation 4% V
Settling Time 500 µs
Short Circuit / Overcurrent Protection Continuous
Current Limit Threshold Range, % of I
Remote Shutdown Positive
Remote Shutdown Reference Vin Negative
Switching Frequency 300 kHz
Isolation
Input - Output 500 VDC
Input - Case 500 VDC
Output - Case 500 VDC
Temperature Coefficient 0.02%/°C
Case Temperature
Operating Range -25 to +60°C
Storage Range -40 to +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 -55 Hz
MTBF† (Bellcore TR-NWT-000332) 1.8 x 106 hrs
Safety UL 1950, CSA 22.2-950, EN60950
Rev. 05/01
Min.- I
out
/ V
out1
out2
Max., Vin Nom., V
out
/ V
out3
Rated ±1% V
out
Rated 130%
out
out1
/ V
out2
/ V
out3
General
±1%, ±5%, ± 5%
±1%, ±5%, ± 5%
FEATURES
• Industry Standard
Package
• 12V Input
• 25W Output
85
80
75
70
65
EFFICIENCY %
60
55
50
85
out
out
out
1
80
75
70
65
EFFICIENCY %
60
55
50
10 20 30 40 50 60 70 80 90 100
1
Industrial temp range of -40 to +85C available, add suffix -I to P/N
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
1
• External Enable Pin
• 5-Sided Shielding
• 500V Isolation
• 85°C Case Operation
Efficiency vs. Load (24V Input)
OWT2405-12
OWT2405-15
10 20 30 40 50 60 70 80 90 100
LOAD %
Efficiency vs. Load (48V Input)
OWT4805-12
OWT4805-15
LOAD %
Notes

OWT SERIES - TRIPLE OUTPUT, 25 WATT
MODELS - (See the last page of Section for options.)
Vin
(Volts)
12
12
24
24
48
48
48 WIDE
48 WIDE
* Maximum input current at minimum input voltage, maximum rated output power.
** At no minal Vin, rated o utput.
Vin Range
(Volts)
10 - 20
10 - 20
18 - 36
18 - 36
20 - 60
20 - 60
36 - 72
36 - 72
Iin Max.*
(Amps)
3.7
3.7
2.4
2.4
2.3
2.3
1.4
1.4
MECHANICAL DRAWING
2.00"
(50.8mm)
0.600"(15.2mm)
0.400"(10.2mm)
0.200"(5.1mm)
1
BOTTOM VIEW
2
3
0
4
Vout
(Volts)
5, ±12
5, ±15
5, ±12
5, ±15
5, ±12
5, ±15
5, ±12
5, ±15
5
6
7
8
Iout Rated
(Amps)
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
3.5, ±0.31
3.5, ±0.25
1.100"(27.9mm)
0.700"(17.8mm)
0.300"(7.6mm)
-0.100"(-2.5mm)
2.00"
(50.8mm)
Ripple & Noise
Pk-Pk (mV)
50, 120
50, 150
50, 120
50, 150
50, 120
50, 150
50, 120
50, 150
DIA 0.040"
(1.0mm)
Effici ency
Typ. **
78%
79%
81%
82%
81%
82%
81%
82%
0.18" MIN.
(4.6mm)
Model
OWT1205-12
OWT1205-15
OWT2405-12
OWT2405-15
OWT4805-12S1
OWT4805-15S1
OWT4805-12
OWT4805-15
-0.50"(-12.7mm)
Thermal Impedance
Natural Convection 14.9 °C/W
100 LFM 11.3 °C/W
200 LFM 8.3 °C/W
300 LFM 6.8 °C/W
400 LFM 5.4 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
-0.10"
(-2.5mm)
0
Pin Function
1.800"
(45.7mm)
1+V
2-V
3 No Conn.
in
in
4 Enable
5 + Aux Out
6 +5V Out
7 Common
8 - Aux Out
0.50"
(12.7mm)
Tolerances
Inches: (Millimeters)
.XX ± 0.040 .X ± 1.0
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
2

OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and
add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used
in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
OPTIONS SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent Compatible Trim T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y Encapsulated EW S, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180"
(4.6mm)
0.110" (2.8mm) Pin Length 8 All Units (Except SMS)
0.150" (3.8mm) Pin Length 9 All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink 1V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink
2H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.45" (11.4mm) Vertical Heatsink 2V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink
3H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Includes Thermal Pad
0.95" (24.1mm) Vertical Heatsink 3V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
Powering Communications and Technology