Datasheet NX350-U4D, NX350-U4E, NX350-U4F, NX350-U4H, NX350-U3A Datasheet (cdtechno)

...
Page 1
Product Data Sheet
350 WATT
AC/DC POWER SUPPLY
NX350
DESCRIPTION
The NX350 is a compact 350 watt Power Factor Corrected, multiple output power supply. All outputs are fully isolated and regulated. Active current sharing circuitry, together with control functions and alarm options, simplifies N+1 and redundant applications. Fan and disk drive applications are handled by the peak current ratings of the auxiliary outputs.
!!
! Active Power Factor Correction
!!
!!
! Fully Isolated Outputs
!!
!!
! Low Profile: 9” x 4.85” x 2.00”
!!
!!
! One, Two, Three and Four Output Models
!!
!!
! N+1 Current Sharing
!!
!!
! FCC/VDE Class B EMI Filter Standard
!!
!!
! Optional Fan Mounted On Cover
!!
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
NX350 3/98 REV B Page 1
AGENCY APPROVALS
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
Page 2
Input Specifications
Parameter Conditions Min Typ Max Units
Operating Range 47-63 Hz 90 264 VAC
Inrush Current Limiting
120VAC, cold start 37 APK
240VAC cold start 70 APK
Efficiency
120V, full load 70 % 240V, full load 75 %
Power Factor Correction (PFC) 0.99
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)
Remote Sense
Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are
protected against open, short and reversal.
Remote On/Of
The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options.
Over Voltag e Protection
Output #1: 6.5V ± 0.5 VDC. The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery upon fault removal.
Transient Response
The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 µsec for a 25% load step change.
Output Isolation
All outputs are fully isolated.
Power Fail Signal
Upon AC input voltage removal, the power fail signal drops to logic zero at least 5msec before loss of DC output. On AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options.
N+1 Load Share
Output #1 has active load sharing circuitry. Units will load share within 1.5% of Maximum Rated Load.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs and automatically restarts.
Safety
UL Recognized: UL File Number E14675 (1950 & 1012) CSA Certified: CSA File Number LR 9070-154C
(C22.2 No. 234-M90, Level 6)
TUV License Number: R9576031 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 30 CFM of airflow.
NX350 3/98 REV BPage 2
Page 3
Output Voltages and Maximum Rated Loads
OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4
MODEL NUMBER VOUT IMAX VNOM IMAX/IPK VNOM IMAX/IPK VNOM IMAX/IPK
NX350-U3A ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A - -
NX350-U3B ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A - -
NX350-U4C ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 5V 3.0A/4.0A
NX350-U4D ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 24V 1.5A/2.0A
NX350-U4E ± 5V 50A ± 12V 10A/12A ± 12V 8A/10A ± 12V 3.0A/4.0A
NX350-U4F ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 5V 3.0A/4.0A
NX350-U4G ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 24V 1.5A/2.0A
NX350-U4H ± 5V 50A ± 15V 10A/12A ± 15V 8A/10A ± 12V 3.0A/4.0A
Note: Peak current ratings are for 10sec maximum. Total power not to exceed 350 watts.
Output Specifications
Parameter Limits
Regulation
Line ± 0.03%
Load ±0.25%
Cross ±0.05%
Minimum Load
Output #1 3.0A
Auxiliary Outputs 0.1A
Hold-Up Time 20mSec at Full Load
Parameter Conditions Min Typ Max Units
Voltage Adustment Range Nominal line on all outputs ±5 %
PARD Peak-to-peak 20 MHz bandwidth 1 %
Temperature
Operating 050°C
Derates to half power 70 °C
Storage -20 +85 °C
Temperature Coefficient (TC) After half hour warm-up ± 0.02 %/°C
NX350 3/98 REV B Page 3
Page 4
Mechanical
TOP VIEW
0.25
0.55
3.90
1
TB1
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER WILL ADD 1.30”. COOLING: The NX350 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The NX350 meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I.) WEIGHT: Approximately 3 lbs.
8.50
9.00
1.95
1
4.85
6-32 THD 4 PLC’S
Maximum depth of mounting
screws is 0.156 inches
1
0.040
COVER
TB2
J9
OUTPUT NO. 1
5v RETURN
5v
Terminal Block 1 Terminal Block 2
POS FUNCTION POS FUNCTION
1 AC Line 1 -V2
2 AC Neutral 2 +V2
3 Ground 3 -V3
4 +V3
5 -V4
6 +V4
Standard Options are shown, consult factory for other available options.
J9 Connector J9 Connector
PIN FUNCTION Molex No.
1 + Sense Connector 22-28-1090
2 - Sense
3N/C
4N/C
5 Start Up Sync.
6Power Fail
7 Remote Inhibit
8 Current Share
9 Cntl Signal Rtn
The information provided herein is believed to be reliable; however, C&D Technologies assumes no responsibility for inaccuracies or omissions. C&D Technologies assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D Technologies does not authorize or warrant any C&D Technologies product for use in life support devices/systems or in aircraft control applications.
NX350 3/98 REV BPage 4
Loading...