Datasheet NTE960 Datasheet (NTE)

Page 1
NTE960
Integrated Circuit
3–Terminal Positive Voltage Regulator, 5V
The NTE960 fixed–voltage regulator is a monolithic integrated circuit in a TO220 type package de­signed for use in a wide variety of applications including local, on–card regulation. This regulator em­ploys internal current limiting, thermal shutdown, and safe–area compensation. With adequate heat­sinking it can deliver output currents in excess of 1.0 ampere.
Features:
Absolute Maximum Ratings: (TA = +25°C unless otherwise specified) Input Voltage, V
Power Dissipation (TA = +25°C), P
in
D
Derate above +25°C 15.4mW/°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Dissipation (TC = +25°C), P
D
Derate above +75°C 200mW/°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Resistance, Junction–to–Ambient, R Thermal Resistance, Junction–to–Case, R Operating Junction Temperature Range, T Storage Junction Temperature Range, T
thJC J
stg
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thJA
–55° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35Vdc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Characteristics: (Vin = 10V, IO = 500mA, TJ = 0° to +125°C unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Output Voltage V
Line Regulation Reg
Load Regulation Reg
TJ = +25°C 4.8 5.0 5.2 V
O
5mA ≤ IO ≤ 1A, PO ≤ 15W, 7V ≤ Vin ≤ 20V 4.75 5.0 5.25 V
lineTJ
loadTJ
= +25°C, Note 1 7V ≤ Vin ≤ 25V – 7 100 mV
8V ≤ Vin ≤ 12V – 2 50 mV
= +25°C, Note 1 5mA ≤ IO ≤ 1.5A – 40 100 mV
250mA ≤ IO ≤ 750mA – 15 50 mV
Note 1. Load and line regulation are specified at constant junction temperature. Changes in VO due
to heating effects must be taken into account separately. Pulse testing with low duty cycle is used.
Page 2
Electrical Characteristics (Cont’d): (Vin = 10V, IO = 500mA, TJ = 0° to +125°C unless otherwise
specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Quiescent Current I Quiescent Current Change ∆I
TJ = +25°C – 4.3 8.0 mA
B
7V ≤ Vin ≤ 25V – – 1.3 mA
B
5mA ≤ IO ≤ 1A – – 0.5 mA Ripple Rejection RR 8V ≤ Vin ≤ 18V, f = 120Hz – 68 – dB Dropout Voltage V Output Noise Voltage V Output Resistance r Short–Circuit Current Limit I Peak Output Current I Average T emperature Coefficient
– V
in
O
sc
max
TCV
= +25°C, IO = 1A – 2 – V
OTJ
TA = +25°C, 10Hz ≤ f ≤ 100kHz – 10 – µV/V
n
f = 1kHz – 17 – mΩ
TA = +25°C, Vin = 35V – 0.2 – A
TJ = +25°C – 2.2 – A
O
– –1.1 – mV/°C
of Output Voltage
.420 (10.67)
Max
O
.147 (3.75)
Dia Max
.070 (1.78)
Max
.100 (2.54)
.110 (2.79)
GND
.500
(12.7)
Max
.250 (6.35)
Max
.500
(12.7)
Min
V
IN
V
OUT
GND
Loading...