NTE1906
Integrated Circuit
Positive 3 Terminal Voltage Regulator,
18V, 100mA
Description:
The NTE1906 is a positive 3–terminal voltage regulator in a TO92 type package suitable for numerous applications requiring up to 100mA. This device features thermal shutdown and current limiting making the NTE1906 remarkably rugged. In most applications, no external components are required.
Features:
D Internal Short–Circuit Current Limiting D Internal Thermal Overload Protection D No External Components Required
Absolute Maximum Ratings:
Input Voltage, V Internal Power Dissipation (Note 1), P Operating Junction Temperature Range, T Maximum Junction Temperature, T Storage Junction Temperature Range, T
I
D
opr
J
stg
Lead Temperature (During Soldring, 10sec), T
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0° to +70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–55° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L
35V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+300°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note 1. Thermal resistance, junction–to–ambient is 180°C/W when mounted with 0.4” leads on a PC
board and 160°C/W when mounted with .250” leads on a PC board.
Electrical Characteristics:
(VI = 27V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0° < TJ < +125°C unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Output Voltage V
Line Regulation Reg
TJ = +25°C 17.3 18.0 18.7 V
O
20.7V ≤ VI ≤ 33V, 1mA ≤ IO ≤ 100mA 17.1 18.0 18.9 V
lineTJ
= +25°C, 20.7V ≤ VI ≤ 33V – – 325 mV
Page 2
Electrical Characteristics (Cont’d): (VI = 27V, IO = 40mA, CI = 0.33µF, CO = 0.1µF,
0° < T
Parameter Symbol Test Conditions Min Typ Max Unit
< +125°C unless otherwise specified)
J
Load Regulation Reg Quiescent Current I Quiescent Current Change ∆I
Output Noise Voltage V Long–Term Stability ∆VO/∆t – 56 – mV/1kHrs Ripple Rejection RR f = 120Hz, 23V ≤ VI ≤ 33V 33 48 – dB Dropout Voltage V
loadTJ
B
B
n
DO
= +25°C, 1mA ≤ IO ≤ 100mA – – 170 mV TJ = +125°C – 2 6 mA With line, 21V ≤ VI ≤ 33V – – 1.5 mA With load, 1mA ≤ IO ≤ 40mA – – 0.1 mA TJ = +25°C, f = 10Hz to 10kHz – 150 – µV
TJ = +25°C, IO = 40mA – 1.7 – V
.135 (3.45) Min
.210
(5.33)
Seating Plane
Max
.500
(12.7)
Min
.100 (2.54)
.105 (2.67) Max
.205 (5.2) Max
V
OUT
GND
V
.021 (.445) Dia Max
IN
.050 (1.27)
.165 (4.2) Max
.105 (2.67) Max