Datasheet NF2EB-12V, NF2EB-5V, NF4EB-24V-1, NF4EB-5V-1, NF4EB-6V-1 Datasheet (NAIS)

...
Page 1
198
NF-RELAYS
FLATPACK RELAY
CSA
mm inch
10.8
.425
20.0
.787
30.2
1.189
FEATURES
1. Flatpack
2. Long seller
SPECIFICATIONS
Contacts
1].
MBB types available: 2MBB & 4MBB (See next page for contact positions.)
Coil
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10 µ s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10 µ s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 25 ° C 77°F, 50% R.H. seal level)
Arrangement
1]
2 Form C, 4 Form C
Initial contact resistance (By voltage drop 6 V DC 1 A)
Max. 50 m Ω Typical 25 m Ω
Contact material
Movable contact Gold-clad silver Stationary contact Gold-clad silver
Rating, (resistive load)
Max. switching power 60 W 100 VA Max. switching voltage 220 V AC, DC Max. switching current 2 A
Expected life (min. operations)
Mechanical 10
8
Electrical (Resistive)
2 A 30 V DC 2 × 10
5
1 A 30 V DC 10
6
0.5 A 30 V DC 10
7
Nominal operating power, at 25 ° C
2C Approx. 300 mW 4C Approx. 480 mW
Max. operating power for continuous duty
Approx. 1 W
at 40 ° C 104 ° F
Max. operating speed 50 cps Initial insulation resistance*
1
1,000 M Ω at 500 V DC
Electrostatic capacitance
Contact/Contact Approx. 4 pF Contact/Coil Approx. 7 pF Contact/Ground Approx. 6 pF
Initial breakdown voltage*
2
Between open contacts 750 Vrms Between contact sets 1,000 Vrms Between live parts and ground 1,000 Vrms Between contacts and coil 1,000 Vrms
Operate time*
3
(at nominal voltage) Max. 15 ms (Approx. 10 ms)
Release time (without diode)*
3
(at nominal voltage)
Max. 10 ms (Approx. 3 ms)
Contact bounce Approx. 1.5 ms
Shock resistance
Functional*
4
In de-energized condition
Min. 29.4 m/s
2
{3 G}
(In contact direction)
Min. 98 m/s
2
{10 G}
(perpendicular to contact)
In energized condition
Min. 196 m/s
2
{20 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
In de-energized condition
29.4 m/s
2
{3 G}, 10 to 55 Hz
at double amplitude of 0.5 mm
(in contact direction)
98 m/s
2
{10 G}10 to 55 Hz
at double amplitude of 1.6 mm
(perpendicular to contact)
In energized condition
117.6 m/s
2
{12 G}10 to 55 Hz
at double amplitude of 2 mm
Destructive
196 m/s
2
{20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
Conditions for operation, transport and storage*
7
(Not freezing and condens­ing at low temperature)
Ambient temp.
–40
°
C to + 65 ° C
–40
°
F to +149 ° F
Humidity 5 to 85%R.H.
Unit weight
2C Approx. 14 g .49 oz 4C Approx. 15.5 g .55 oz
TYPICAL APPLICATIONS
NF relays are widely acceptable in appli­cations where small size and high sensi­tivity are required. Such applications include: Electronic equipment, Household applications,
Alarm systems, Office machines, Com­munication equipment, Measuring equip­ment, Remote control systems, General control circuits, Machine tools, Industrial machinery, etc.
Page 2
NF
199
ORDERING INFORMATION
Ex. NF
Contact arrangement Type classification MBB function Contact metarialCoil voltage (DC)
2: 2 Form C 4: 4 Form C
EB: Standard Nil: Form C type
2M: 2MBB (2 Form D) 4M: 4MBB (4 Form D)
5, 6, 12, 24, 48 V
Nil: Gold-clad silver 1: Gold-cap over silver palladium
4 EB 4M 48V 1
(Notes) 1. For VDE recognized types, add suffix VDE.
(Notes) 2. For UL/CSA recognized type, add suffix-A, as NF2EB-12V-A whose ground terminal is cut off. (Notes) 3. Standard packing Carton: 20 pcs.; Case: 200 pcs.
*Less than 1,000 Ω : *More than 1,000 Ω :
±
10%
±
15%
Part No.
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max. allowable
voltage,
V DC (at 40 ° C)
Coil resistance,*
Nominal
operating power ,
mW
Inductance, H
Armarure
Open Close NF2EB-5V 5 4.0 0.5 8.7 90 278 0.071 0.071 NF2EB-6V 6 4.8 0.6 10.5 137 260 0.093 0.094 NF2EB-12V 12 9.6 1.2 21 500 290 0.338 0.344 NF2EB-24V 24 19.2 2.4 42 2,000 290 1.29 1.31 NF2EB-48V 48 38.4 4.8 84 7,000 330 4.12 4.18 NF4EB-5V 5 4.0 0.5 7 53 472 0.029 0.029 NF4EB-6V 6 4.8 0.6 8.5 90 400 0.070 0.071 NF4EB-12V 12 9.6 1.2 17.0 330 440 0.22 0.23 NF4EB-24V 24 19.2 2.4 34 1,200 480 0.77 0.79 NF4EB-48V 48 38.4 4.8 68 4,200 550 2.22 2.25
DIMENSIONS
2 Form C
10.8±0.3
.425±.012
0.3
.012
3.3
.130
Resin rise max. 0.5
max. .020
4-0.8 dia.
.031 dia.
Stand-off
20.6
.811
30.2
1.189
20
.787
13
.512
N.O.
Ground terminal
N.C.
Coil terminal
Common terminal
Terminal dimensions (except soldering) Width: 0.8 .031 Thickness: 0.3 .012
MBB contact position NF2-2M: terminal 6-7-8, 3-4-5
58
47
12
36
Schematic
PC board pattern (Copper-side view)
(2.54)
(.100)
7.6±0.2
.3±.008
7.6±0.2
.3±.008
12.7±0.2
.5±.008
(2.54)
(.100)
4.9
.193
5.1±0.2
.2±.008
4.9
.193
1.13
.044
1.13
.044
1.3
.051 DIA.
+0 –0.3
+0 –.012
Relay outline
mm inch
4 Form C
General tolerance: ± 0.5 ± .020
(Except for the cover height)
811
710
12
6
5
4
39
14
13
12
10.8±0.3
.425±.012
0.3
.012
3.3
.130
Resin rise max. 0.5
max. .020
4-0.8 dia.
.031 dia.
Stand-off
20.6
.811
30.2
1.189
24.6
.969
13.6
.535
N.O.
Ground terminal
N.C.
Coil terminal
Common terminal
Terminal dimensions (except soldering) Width: 0.8 .031 Thickness: 0.3 .012
Schematic
MBB contact position NF4-2M: terminals 6-7-8, 9-10-11 NF4-2M: terminals 6-7-8, 3-4-5, 12-13-14, 9-10-11
PC board pattern (Copper-side view)
(2.54)
(.100)
7.6±0.2
.3±.008
7.6±0.2
.3±.008
12.7±0.2
.5±.008
(2.54)
(.100)
2.1
.083
5.1±0.2
.2±.008
2.1
.083
1.13
.044
1.13
.044
1.3
.051 DIA.
Relay outline
+0 –0.3
+0 –.012
TYPES AND COIL DATA (at 25 ° C 77 ° F)
Page 3
NF
200
REFERENCE DATA
1. Life curve 2. Coil temperature rise (resistance method) 3. H
2
S gas test
0.5 1 1.5 2 2.5
10
100
1,000
30 V DC Resistive
Load current, A
No. of operations, ×10
4
0.2 0.4 0.6 0.8 1.0 1.2 1.4
20
40
60
Coil temperature rise, °C
Operating power, W
Exposure time, hrs
50m
100m
500m
1
5
10
50
100
Contact resistance
20 50100 200 1,000
2,000500
Gas density: 2 to 5 ppm Temperature: 40°C Humidity: 90%
Sealed NFEB relay
4. Contact reliability Test conditions:
1. Contact current/voltage: 10 µ A 100 mV 1 kHz
2. Cycle rate 20 cps.
3. Miscontact detection level: 1 mW (= 100 Ω )
4. Detection method: Observation of all changeover contacts
Test result:
m = 1.5
µ
= 21.2 × 10
6
95% confidence level = 3.1 × 10
6
17 contacts out of 20 achieved 10 million no miscon­tact operations.
0.1 0.5 1.0 5.0 10.0 50 100
0.1
0.2
0.15
0.3
0.4
0.5
1.0
1.5
2.0
3.0
4.0
5.0
10.0
20.0
25.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
95.0
99.0
99.9
15.0
No. of operations, ×10
6
F(t)(%)
5. High temperature test Test conditions:
Ambient temperature: 80 ° C ± 2 ° C
Test method:
1. All contacts were switched for 100 operations on 2 A 30 V DC resistive load.
2. Samples then were exposed to 80 ° C temperature for 5,000 hours, continuous
3. Contact resistance was measured with Hewlett­Packard testing equipment.
Test result:
Amber relays showed a stable spread of contact resis­tance within the initially specified 50 m Ω after 5,000 hours exposure.
100 200 300 400 500 1,000 5,000
3,000
0
10
20
30
40
50
60
70
Contact resistance, m
Exposure, hrs.
N.C. contacts
N.O. contacts
Min.
Max.
Min.
Max.
NOTES
1. Prevention of vibration and shock
To reduce the likelihood of vibration and shock, we recommend that you install so that the contact action is not in the direc­tion of gravity.
Top
Common terminal
Coil terminal
NC terminal
NO terminal
Bottom
For Cautions for Use, see Relay Technical Information (Page 48 to 76).