Datasheet NCB2-12GM40-Z0-V1-3G-3D DataSheet (Pepperl Fuchs)

Page 1
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Technical Data
General specifications
Switching function Normally open (NO) Output type Two-wire Rated operating distance sn2 mm Installation flush Output polarity DC
Model Number
NCB2-12GM40-Z0-V1-3G-3D
Features
• ATEX-approval for zone 2 and zone 22
Accessories
EXG-12
Quick mounting bracket with dead stop
BF 12
Mounting flange, 12 mm
Assured operating distance s Actual operating distance sr1.8 ... 2.2 mm typ. Reduction factor r Reduction factor rCu 0.23 Reduction factor r
Nominal ratings
Operating voltage UB5 ... 60 V DC Switching frequency f 0 ... 800 Hz Hysteresis H 1 ... 10 typ. 5 % Reverse polarity protection reverse polarity tolerant Short-circuit protection pulsing Vol tag e d rop Ud≤ 5 V
S
Operating current I Lowest operating current I Off-state current I Switching state indicator Multihole-LED, yellow
Functional safety related parameters
MTTFd 2090 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP67
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC)
0.28
Al
0.7
304
) 20 a
M
0 ... 1.62 mm
a
2 ... 100 mA
L
2 mA
m
0 ... 0.5 mA typ.
r
3G; 3D
EN 60947-5-2:2007 IEC 60947-5-2:2007
Dimensions
Electrical Connection
17
LED
M12x1
3
M12x1
4
39
45
55
6
L+
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
L-
1
Page 2
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Pinout
1
2
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
4
3
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Equipment protection level Gc (nA)
Instruction Manual electrical apparatus for hazardous areas
Device category 3G (nA) for use in hazardous areas with gas, vapour and mist
Certificate of Compliance PF 15CERT3754 X CE marking
ATEX ma rk in g ¬ II 3G Ex nA IIC T6 Gc
Standards EN 60079-0:2012+A11:2013, EN 60079-15:2010
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
Maximum operating current I
Maximum operating voltage U
Maximum permissible ambient temperature T
at U at U at U
=60 V, IL=100 mA
Bmax
=60 V, IL=50 mA
Bmax
=60 V, IL=25 mA
Bmax
L
Bmax
Umax
Protection from mechanical danger Protection from UV light
Protection against transients
Electrostatic charge
Material selection accessories
Plug connector
The Ex-related marking can also be printed on the enclosed label.
Ignition protection category "n" Use is restricted to the following stated conditions
and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed!
be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indel­ible, including in the event of possible chemical corrosion.
Repairs to these apparatus are not possible.
The maximum permissible load current must be restricted to the values given in the fol­lowing list. High load currents and load short-circuits are not permitted.
The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
dependant of the load current I Information can be taken from the following list.
and the max. operating voltage U
L
Bmax
47 °C (116.6 °F) 56 °C (132.8 °F) 60 °C (140 °F) The sensor must not be exposed to ANY FORM of mechanical danger. The sensor and the connection cable must be protected from damaging UV-radiation.
This can be achieved when the sensor is used in internal areas. Ensure transient protection is provided and that the maximum value of the transient pro-
tection (140% of 85 V) is not exceeded. Electrostatic charges must be avoided on the mechanical housing components. Dan-
gerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding.
When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 °C.
The plug connector must not be withdrawn under voltage. The proximity switch is identi­fied as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Equipment protection level Dc
Note This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with non-conducting combustible dust
CE marking
ATEX marking ¬ II 3D IP67 T 92 °C (197.6 °F) X
Standards EN 50281-1-1
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed.
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
Maximum operating voltage U
Maximum operating current I
Maximum heating (Temperature rise)
at U at U at U Protection from mechanical danger
Electrostatic charge
Plug connector
=60 V, IL=100 mA
Bmax
=60 V, IL=50 mA
Bmax
=60 V, IL=25 mA
Bmax
Note the ex-marking on the sensor or on the enclosed adhesive label
The Ex-significant identification is on the enclosed adhesive label
Protection via housing Use is restricted to the following stated conditions
The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!
The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possi­bility of chemical corrosion!
Repairs to these apparatus are not possible.
The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are
Bmax
not permitted. The maximum permissible load current must be restricted to the values given in the following list.
L
High load currents and load short-circuits are not permitted. dependant of the load current I
Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus.
22 K 14 K 10 K The sensor must not be mechanically damaged.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding.
The plug connector must not be disconnected under voltage. The proximity switch is marked as follows: "DO NOT DISCON­NECT UNDER VOLTAGE!" When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas, which are not accessible in the plugged-in condition) must be prevented. The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs).
and the max. operating voltage U
L
Bmax
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Page 5
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Equipment protection level Dc (tD)
Note This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with combustible dust
CE marking
ATEX ma rk in g ¬ II 3D Ex tD A22 IP67 T80°C X
Standards EN 61241-0:2006, EN 61241-1:2004
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed.
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
Maximum operating current I
Maximum operating voltage U
Maximum permissible ambient tempera­ture T
at U at U at U
Umax
=60 V, IL=100 mA
Bmax
=60 V, IL=50 mA
Bmax
=60 V, IL=25 mA
Bmax
L
Bmax
Protection from mechanical danger Protection from UV light
Electrostatic charge
Plug connector
Note the ex-marking on the sensor or on the enclosed adhesive label
The Ex-significant identification is on the enclosed adhesive label
Protection via housing "tD" Use is restricted to the following stated conditions
The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!
The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possi­bility of chemical corrosion!
Repairs to these apparatus are not possible.
The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
dependant of the load current I Information can be taken from the following list.
and the max. operating voltage U
L
Bmax
48 °C (118.4 °F) 56 °C (132.8 °F) 60 °C (140 °F) The sensor must not be exposed to ANY FORM of mechanical danger. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is
used in internal areas. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the
mechanical housing components can be avoided by incorporating these in the equipotential bonding. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT
SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs).
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
5
Page 6
Inductive sensor NCB2-12GM40-Z0-V1-3G-3D
Equipment protection level Dc (tc)
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with combustible dust
Certificate of Compliance PF 15CERT3774 X CE marking
ATEX marking ¬ II 3D Ex tc IIIC T80°C Dc
Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014
Ge n e r a l The corresponding datasheets, declarations of conformity, EC-type examination certifi-
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
Maximum operating current I
Maximum operating voltage U
Maximum permissible ambient temperature T
at U at U at U Protection from mechanical danger
=60 V, IL=100 mA
Bmax
=60 V, IL=50 mA
Bmax
=60 V, IL=25 mA
Bmax
L
Bmax
Umax
Protection from UV light
Electrostatic charge
Plug connector
The Ex-related marking can also be printed on the enclosed label.
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
cates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl­fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The back­ground surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
Repairs to these apparatus are not possible.
The maximum permissible load current must be restricted to the values given in the fol­lowing list. High load currents and load short-circuits are not permitted.
The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
dependant of the load current I Information can be taken from the following list.
and the max. operating voltage U
L
Bmax
48 °C (118.4 °F) 56 °C (132.8 °F) 60 °C (140 °F) The sensor must not be exposed to ANY FORM of mechanical danger. The sensor and the connection cable must be protected from damaging UV-radiation.
This can be achieved when the sensor is used in internal areas. Electrostatic charges must be avoided on the mechanical housing components. Dan-
gerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up.
The plug connector must not be withdrawn under voltage. The proximity switch is identi­fied as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
Release date: 2016-11-07 10:03 Date of issue: 2016-11-07 183042_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
6