Datasheet NCB10-30GM40-N0-15M-PUR DataSheet (Pepperl Fuchs)

Page 1
Inductive sensor NCB10-30GM40-N0-15M-PUR
Technical Data
General specifications
Switching function Normally closed (NC) Output type NAMUR Rated operating distance sn10 mm Installation flush Assured operating distance sa0 ... 8.1 mm
0102
Model Number
NCB10-30GM40-N0-15M-PUR
Features
• 10 mm flush
Accessories
BF 30
Mounting flange, 30 mm
Actual operating distance s Reduction factor rAl 0.32 Reduction factor r Reduction factor r
Nominal ratings
Nominal voltage Uo8 V Switching frequency f 0 ... 650 Hz Hysteresis H 1 ... 10 typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Current consumption
Measuring plate not detected Measuring plate detected
Switching state indicator LED, yellow
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F) Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type cable PUR , 15 m Core cross-section 0.75 mm Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP66 / IP67 Cable
Bending radius
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Stan dard conf ormit y
NAMUR
Sta ndar ds
0.32
Cu
0.72
304
9 ... 11 mm typ.
r
3 mA 1 mA
> 10 x cable diameter
1G; 2G; 3G; 1D
EN 60947-5-6:2000 IEC 60947-5-6:1999
EN 60947-5-2:2007 IEC 60947-5-2:2007
2
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
Dimensions
M30x1,5
LED
37
40
5
36
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Page 2
Inductive sensor NCB10-30GM40-N0-15M-PUR
Electrical Connection
BN
BU
L+
L-
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Inductive sensor NCB10-30GM40-N0-15M-PUR
Equipment protection level Ga
Instruction Manual electrical apparatus for hazardous areas
Device category 1G for use in hazardous areas with gas, vapour and mist
EC-Type Examination Certificate PTB 00 ATEX 2048 X
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga The Ex-related marking can also be printed on the
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Appropriate type NCB10-30GM...-N0...
Effective internal inductivity C
Effective internal inductance L
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Ambient temperature Details of the correlation between the type of circuit connected, the maximum per-
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions The connecting parts of the sensor must be set up in such a way that degree of pro-
Protection from mechanical danger
Electrostatic charge
i
i
enclosed label.
Use is restricted to the following stated conditions
105 nF ; a cable length of 10 m is considered.
100 µH ; a cable length of 10 m is considered.
and in this instruction manual. The EU-type examination certificate has to be observed. The special conditions must be adhered to! The ATEX directive and therefore the EU-type examination certificates apply in gen­eral only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permis­sible minimum ignition energies may have to be taken into consideration.
missible ambient temperature, the temperature class, and the effective internal reac­tance values can be found on the EC-type examination certificate. Note: temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127­1 has already been applied to the temperature table for category 1.
must be observed. The intrinsic safety is only assured in connection with an appropriate related appara­tus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. If the Ex­related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion.
Repairs to these apparatus are not possible.
tection IP20, in accordance with lEC 60529, is achieved as a minimum.
When using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as pro­vided in the datasheet must also be observed.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Additional requirements for gas group IIC. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device.
Use the
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Inductive sensor NCB10-30GM40-N0-15M-PUR
Equipment protection level Gb
Instruction Manual electrical apparatus for hazardous areas
Device category 2G for use in hazardous areas with gas, vapour and mist
EC-Type Examination Certificate PTB 00 ATEX 2048 X
CE marking 0102
ATE X m ar king ¬ II 1G Ex ia IIC T6T1 Ga
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Appropriate type NCB10-30GM...-N0...
Effective internal inductivity C
Effective internal inductance L
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Maximum permissible ambient temperature T
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions The connecting parts of the sensor must be set up in such a way that degree of pro-
Protection from mechanical danger
Electrostatic charge
i
i
amb
The Ex-significant identification is on the enclosed adhesive label
Use is restricted to the following stated conditions
105 nF ; a cable length of 10 m is considered.
100 µH ; a cable length of 10 m is considered.
and in this instruction manual. The EU-type examination certificate has to be observed. The special conditions must be adhered to! The ATEX directive and therefore the EU-type examination certificates apply in gen­eral only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permis­sible minimum ignition energies may have to be taken into consideration.
Details of the correlation between the type of circuit connected, the maximum per­missible ambient temperature, the temperature class, and the effective internal reac­tance values can be found on the EC-type examination certificate.
must be observed. The intrinsic safety is only assured in connection with an appro­priate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indeli­ble, including in the event of possible chemical corrosion.
Repairs to these apparatus are not possible.
tection IP20, in accordance with lEC 60529, is achieved as a minimum.
When using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding.
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Page 5
Inductive sensor NCB10-30GM40-N0-15M-PUR
Equipment protection level Gc (ic)
Instruction Manual electrical apparatus for hazardous areas
Device category 3G (ic) for use in hazardous areas with gas, vapour and mist
Certificate of Compliance PF 13 CERT 2895 X
CE marking
ATEX marking ¬ II 3G Ex ic IIC T6T1 Gc
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category "ic"
Effective internal inductivity C
Effective internal inductance L
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
for Pi=34 mW, Ii=25 mA, T6
for Pi=34 mW, Ii=25 mA, T5
for Pi=34 mW, Ii=25 mA, T4-T1
for Pi=64 mW, Ii=25 mA, T6
for Pi=64 mW, Ii=25 mA, T5
for Pi=64 mW, Ii=25 mA, T4-T1
for Pi=169 mW, Ii=52 mA, T6
for Pi=169 mW, Ii=52 mA, T5
for Pi=169 mW, Ii=52 mA, T4-T1
for Pi=242 mW, Ii=76 mA, T6
for Pi=242 mW, Ii=76 mA, T5
for Pi=242 mW, Ii=76 mA, T4-T1
Protection from mechanical danger
i
i
The Ex-significant identification is on the enclosed adhesive label
Use is restricted to the following stated conditions
105 nF ; a cable length of 10 m is considered.
100 µH ; A cable length of 10 m is considered.
and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! The ATEX Directive applies only to the use of apparatus under atmospheric condi­tions. If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be dura­ble and remain legible, with due consideration of the possibility of chemical corro­sion!
Repairs to these apparatus are not possible.
70 °C (158 °F)
85 °C (185 °F)
100 °C (212 °F)
70 °C (158 °F)
85 °C (185 °F)
100 °C (212 °F)
62 °C (143.6 °F)
77 °C (170.6 °F)
81 °C (177.8 °F)
54 °C (129.2 °F)
63 °C (145.4 °F)
63 °C (145.4 °F)
The sensor must not be mechanically damaged. When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing.
Electrostatic charge
Connection parts
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding.
The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529.
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
5
Page 6
Inductive sensor NCB10-30GM40-N0-15M-PUR
Equipment protection level Da
Instruction Manual electrical apparatus for hazardous areas
Device category 1D for use in hazardous areas with combustible dust
EC-Type Examination Certificate PTB 00 ATEX 2048 X
CE marking 0102
ATE X m ar king ¬ II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Appropriate type NCB10-30GM...-N0...
Effective internal inductivity C
Effective internal inductance L
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Maximum permissible ambient temperature T
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions The connecting parts of the sensor must be set up in such a way that degree of pro-
Protection from mechanical danger
Electrostatic charge
i
i
amb
enclosed label.
Use is restricted to the following stated conditions
105 nF ; a cable length of 10 m is considered.
100 µH ; a cable length of 10 m is considered.
and in this instruction manual. The EU-type examination certificate has to be observed. The ATEX directive and therefore the EU-type examination certificates apply in gen­eral only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permis­sible minimum ignition energies may have to be taken into consideration.
Details of the correlation between the type of circuit connected, the maximum per­missible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate.
The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
must be observed. The intrinsic safety is only assured in connection with an appropriate related appara­tus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indeli­ble, including in the event of possible chemical corrosion.
Repairs to these apparatus are not possible.
tection IP20, in accordance with lEC 60529, is achieved as a minimum.
When using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specifica­tion IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where elec­trostatic charge can build up.
Release date: 2016-11-09 09:15 Date of issue: 2016-11-09 208595_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
6