Min. 200 x 10
Min. 500 x 103 operations (1A, 30VDC)
1,000VAC (50/60Hz) 1min
1,500V / 10 x 700µs standard wave
Single winding
latching type
6
Min. 10 x 106 operations
3
operations (0.5A, 125VAC),
Double winding
latching type
1,000VAC (50/60Hz)
1min
1,500V / 10 x 160µs
standard wave
* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual
load before production since reference values may vary according to switching frequencies, environmental conditions
Note: All values in the tables are valid for 20°C and zero contact current.
* Specified operate values are valid for pulse wave voltage.
Please use at
rated coil voltage. Please refer to characteristic data and set up adequate voltage in case of use at over voltage.
3
Page 4
FTR-K1 SERIES
n COIL RATING
Double winding latching type
NA SERIES
Coil
Code
1.51.5P 11.25+1.13
33P 45+2.25
4.54.5P 101+3.38
55P 125+3.75
66P 180+4.5
99P 405+6.75
1212P 720+9
1818P 1,080+13.5
2424P 1,920+18
Rated Coil
Voltage
(VDC)
Coil Resistance
+/- 10% (Ohm)
S 11.25+1.13
S 45+2.25
S 101+3.38
S 125+3.75
S 180+4.5
S 405+6.75
S 720+9
S 1,080+13.5
S 1,920+18
Set Voltage
(VDC) *
Reset
Voltage
(VDC) *
Rated Power
(mW)
200
300
Note: All values in the table are measured at 20°C and zero contact current.
* Specied values are measured with pulse wave voltage
Please use at rated coil voltage. Please refer to characteristic data and set up adequate voltage in case of use at over voltage.
P: Primary coil S: Secondary coil
n SAFETY STANDARDS
TypeComplianceContact rating
ULUL 508, UL 1950
E 45026
LR 35579
Complies to IEC60950-1; FCC part 68: Telcordia
(Relay is only marked with UL and CSA logo)
Flammability: UL 94-V0 (plastics)
0.5A, 125VAC (general use)
2A, 30VDC (resistive)
0.3A, 110VDC (resistive)CSAC22.2 No. 14, No. 950
4
Page 5
FTR-K1 SERIES
n CHARACTERISTIC DATA
NA SERIES
5
Page 6
FTR-K1 SERIES
NA SERIES
6
Page 7
DIMENSIONS
NA (standard type)
NAL (single winding latching type)
FTR-K1 SERIES
NA SERIES
Dimensions
15.2 max.
14.9 typ.
9.7 typ.
10 max.
3.0
(1.1)
0.50.2
45.245.25.08
NAL-D (double winding latching type)
Dimensions
15.2 max.
14.9 typ.
9.7 typ.
10 max.
3.0
(1.1)
0.50.2
2.54
2.54
2.545.08
(1.16)
(1.16)
7.7 max.
7.4 typ.
5.08
7.7 max.
7.4 typ.
5.08
Schematics
(BOTTOM VIEW)
13
+(-)
-(+)
1210
Orientation mark
Schematics
(BOTTOM VIEW)
1
1210 98
Orientation mark
3
45
PS
-(+)
45
98
PC board mounting
hole layout
(BOTTOM VIEW)
14.9
7.4
(1.1)5.082.54 2.54
8- φ0.8
5.08(1.16)
PC board mounting
hole layout
(BOTTOM VIEW)
14.9
(+)+(-)
7.4
(-)
(1.1)5.082.54 2.54 2.54
10- φ0.8
5.08(1.16)
* Contacts drawn in reset condition.
* +/-: set voltage applied polarity, (+)/(-):
reset voltage applied polarity.
* P: Set coil, S: Reset coil
* Dimensions of the terminals do not include thickness of pre-solder.
* Dimensions do not include tolerances.
* Toleranes of PC board mounting hole layout: ±0.1 unless otherwise specified.
Unit: mm
7
Page 8
FTR-K1 SERIES
NA SERIES
RoHS Compliance and Lead Free Information
1. General Information
l All relays produced by Fujitsu Components are compliant with RoHS directive 2011/65/EU including
amendments.
l Cadmium as used in electrical contacts is exempted from the RoHS directives.
As per Annex III of directive 2011/65/EU.
l All relays are lead-free. Please refer to Lead-Free Status Info for older date codes at:
FUJITSU COMPONENTS AMERICA, INC
2290 North First Street, Suite 212
San Jose, CA 95131, USA
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Email: components@us.fujitsu.com
Web: us.fujitsu.com/components
FUJITSU ELECTRONIC COMPONENTS (SHANGHAI) CO., LTD.
Unit 4306, InterContinental Center
100 Yu Tong Road, Shanghai 200070,
China
Tel: (86-21) 3253 0998
Fax: (86-21) 3253 0997
Email: fcsh@cn.fujitsu.com
Web: www.fujitsu.com/cn/products/devices/components/
Hong Kong
FUJITSU COMPONENTS HONG KONG CO., LTD
Unit 506, Inter-Continental Plaza
No.94 Granville Road, Tsim Sha Tsui, Kowloon,
Hong Kong
Tel: (852) 2881-8495
Tex: (852) 2894-9512
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components/
The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for general information purposes.
The use of the contents, data and information provided in this datasheet is at the users’ own risk.
Fujitsu has assembled this datasheet with care and will endeavor to keep the contents, data and information correct, accurate, comprehensive,complete and up to
date.
Fujitsu Components Europe B.V. and affiliated companies do however not accept any responsibility or liability on their behalf, nor on behalf of its employees, for
any loss or damage, direct, indirect or consequential, with respect to this datasheet, its contents, data, and information and related graphics and the correctness,
reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof.
Nor do Fujitsu Components Europe B.V. and affiliated companies accept on their behalf, nor on behalf of its employees, any responsibility or liability with respect
to these datasheets, its contents, data, information and related graphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and
completeness thereof. Rev. July 9, 2019
9