Datasheet MX28F2000PTC-70C4, MX28F2000PTC-90C4, MX28F2000PPC-12C4, MX28F2000PPC-70C4, MX28F2000PPC-90C4 Datasheet (MXIC)

...
Page 1
FEATURES
MX28F2000P
2M-BIT [256K x 8] CMOS FLASH MEMORY
• 262,144 bytes by 8-bit organization
• Fast access time: 70/90/120 ns
• Low power consumption – 50mA maximum active current – 100uA maximum standby current
• Programming and erasing voltage 12V ± 5%
• Command register architecture – Byte Programming (15us typical) – Auto chip erase 5 seconds typical
(including preprogramming time)
– Block Erase
• Optimized high density blocked architecture – Four 4-KB blocks (Top) – Fourteen 16-KB blocks – Four 4-KB blocks (Bottom)
GENERAL DESCRIPTION
The MX28F2000P is a 2-mega bit Flash memory or­ganized as 256K bytes of 8 bits each. MXIC's Flash memories offer the most cost-effective and reliable read/write non-volatile random access memory. The MX28F2000P is packaged in 32-pin PDIP, PLCC and TSOP. It is designed to be reprogrammed and erased in-system or in-standard EPROM program­mers.
The standard MX28F2000P offers access times as fast as 70 ns, allowing operation of high-speed microprocessors without wait states. To eliminate bus contention, the MX28F2000P has separate chip enable (CE) and output enable (OE ) controls.
MXIC's Flash memories augment EPROM function­ality with in-circuit electrical erasure and programming. The MX28F2000P uses a command register to manage this functionality, while maintaining a standard 32-pin pinout. The command register allows for 100% TTL level control inputs and fixed power supply levels during erase and programming, while maintaining maximum EPROM compatibility.
• Auto Erase (chip & block) and Auto Program – DATA polling – Toggle bit
• 10,000 minimum erase/program cycles
• Latch-up protected to 100mA from -1 to VCC+1V
• Advanced CMOS Flash memory technology
• Compatible with JEDEC-standard byte-wide 32-pin EPROM pinouts
• Package type: – 32-pin plastic DIP – 32-pin PLCC – 32-pin TSOP (Type 1)
MXIC Flash technology reliably stores memory con­tents even after 10,000 erase and program cycles. The MXIC cell is designed to optimize the erase and programming mechanisms. In addition, the combi­nation of advanced tunnel oxide processing and low internal electric fields for erase and programming operations produces reliable cycling. The MX28F2000P uses a 12.0V ± 5% VPP supply to perform the Auto Program/Erase algorithms.
The highest degree of latch-up protection is achieved with MXIC's proprietary non-epi process. Latch-up protection is proved for stresses up to 100 milliamps on address and data pin from -1V to VCC + 1V.
P/N: PM0380
1
REV. 1.5, OCT 29, 1998
Page 2
MX28F2000P Block Address and Block Structure
MX28F2000P
A17~A0
3FFFFH
3F000H
3EFFFH
3E000H
3DFFFH
3D000H
3CFFFH
3C000H
3BFFFH
38000H
37FFFH
34000H
33FFFH
30000H
2FFFFH
2C000H 2BFFFH
28000H 27FFFH
24000H 23FFFH
20000H
1FFFFH 1C000H
1BFFFH
18000H 17FFFH
14000H 13FFFH
10000H
0FFFFH 0C000H
0BFFFH
08000H 07FFFH
04000H 03FFFH
03000H 02FFFH
02000H 01FFFH
01000H 00FFFH
00000H
4-K byte 4-K byte
4-K byte 4-K byte 16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
16-K byte
4-K byte
4-K byte
4-K byte 4-K byte
P/N: PM0380
2
REV. 1.5, OCT 29, 1998
Page 3
PIN CONFIGURATIONS
A11
A9
A8 A13 A14 A17
WE
VCC
VPP
A16 A15 A12
A7
A6
A5
A4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OE A10 CE Q7 Q6 Q5 Q4 Q3 GND Q2 Q1 Q0 A0 A1 A2 A3
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
MX28F2000P
MX28F2000P
32 PDIP
32 PLCC
VPP
1
A16
2
A15
3
A12
4
A7
5
A6
6
A5
7
A4
8
A3
9
A2
10
A1
11
A0
12
Q0
13
Q1
14
Q2
15
GND
16
A12
A15
4
5
A7 A6 A5 A4
MX28F2000P
9
A3 A2 A1 A0
13
Q0
14 17 20
MX28F2000P
A16
VPP
VCCWEA17
1
32
TSOP (TYPE 1)
VCC
32
WE
31
A17
30
A14
29
A13
28
A8
27
A9
26
A11
25
OE
24
A10
23
CE
22
Q7
21
Q6
20
Q5
19
Q4
18
Q3
17
(NORMAL TYPE)
1
32
OE
CE Q7 Q6 Q5 Q4 Q3
Q2 Q1 Q0
31 30 29 28 27 26 25 24 23 22 21 20
A0
19
A1
18
A2
17
A3
MX28F2000P
A10
30
29
A14 A13 A8 A9
25
A11 OE A10 CE
21
Q7
GND
A11
2
A9
3
A8
4
A13
5
A14
6
A17
7
WE
8
VCC
9
VPP
10
A16
11
A15
12
A12
13
A7
14
A6
15
A5
16
A4
Q1
Q2
Q3Q4Q5
VSS
Q6
(REVERSE TYPE)
PIN DESCRIPTION:
SYMBOL PIN NAME
A0~A17 Address Input Q0~Q7 Data Input/Output CE Chip Enable Input OE Output Enable Input WE Write enable Pin
P/N: PM0380
VPP Program Supply Voltage VCC Power Supply Pin (+5V) GND Ground Pin
3
REV. 1.5, OCT 29, 1998
Page 4
BLOCK DIAGRAM
MX28F2000P
CE
OE
WE
A0-A17
CONTROL INPUT
LOGIC
ADDRESS
LATCH
AND
BUFFER
PROGRAM/ERASE
HIGH VOLTAGE
X-DECODER
MX28F2000P
FLASH ARRA Y
Y-DECODER
Y-PASS GATE
SENSE
AMPLIFIER
PGM
DATA
HV
PROGRAM
DATA LATCH
ARRAY
SOURCE
HV
MODE LOGIC
STATE
REGISTER
COMMAND
DATA DECODER
COMMAND
DATA LATCH
P/N: PM0380
Q0-Q7
I/O BUFFER
4
REV. 1.5, OCT 29, 1998
Page 5
MX28F2000P
AUTOMATIC PROGRAMMING
The MX28F2000P is byte programmable using the Automatic Programming algorithm. The Automatic Programming algorithm does not require the system to time out or verify the data programmed. The typical room temperature chip programming time of the MX28F2000P is less than 5 seconds.
AUTOMATIC CHIP ERASE
The device may be erased using the Automatic Erase algorithm. The Automatic Erase algorithm automati­cally programs the entire array prior to electrical erase. The timing and verification of electrical erase are controlled internal to the device.
AUTOMATIC BLOCK ERASE
The MX28F2000P is block(s) erasable using MXIC's Auto Block Erase algorithm. Block erase modes allow blocks of the array to be erased in one erase cycle. The Automatic Block Erase algorithm automatically programs the specified block(s) prior to electrical erase. The timing and verification of electrical erase are controlled internal to the device.
AUTOMATIC PROGRAMMING ALGORITHM
MXIC's Automatic Programming algorithm requires the user to only write a program set-up command and a program command (program data and address). The device automatically times the programming pulse width, provides the program verify, and counts the number of sequences. A status bit similar to DATA polling and a status bit toggling between consecutive read cycles, provide feedback to the user as to the status of the programming operation.
AUTOMATIC ERASE ALGORITHM
MXIC's Automatic Erase algorithm requires the user to only write an erase set-up command and erase com­mand. The device will automatically pre-program and verify the entire array. Then the device automatically times the erase pulse width, provides the erase verify, and counts the number of sequences. A status bit similar to DATA polling and a status bit toggling between consecutive read cycles, provide feedback to the user as to the status of the erase operation.
Commands are written to the command register using standard microprocessor write timings. Register con­tents serve as inputs to an internal state-machine which controls the erase and programming circuitry. During write cycles, the command register internally latches address and data needed for the programming and erase operations. For system design simplifica­tion, the MX28F2000P is designed to support either WE or CE controlled writes. During a system write cycle, addresses are latched on the falling edge of WE or CE whichever occurs last. Data is latched on the rising edge of WE or CE whichever occur first. To simplify the following discussion, the WE pin is used as the write cycle control pin throughout the rest of this text. All setup and hold times are with respect to the WE signal.
MXIC's Flash technology combines years of EPROM experience to produce the highest levels of quality, relia­bility, and cost effectiveness. The MX28F2000P electri­cally erases all bits simultaneously using Fowler-Nord­heim tunneling. The bytes are programmed one byte at a time using the EPROM programming mechanism of hot electron injection.
P/N: PM0380
5
REV. 1.5, OCT 29, 1998
Page 6
MX28F2000P
TABLE 1. COMMAND DEFINITIONS
COMMAND BUS FIRST BUS CYCLE SECOND BUS CYCLE
CYCLES OPERATION ADDRESS DATA OPERATION ADDRESS DATA
Read Memory 1 Write X 00H Read Identified codes 2 Write X 90H Read IA ID Setup auto erase/ 2 Write X 30H Write X 30H
auto erase (chip) Setup auto erase/ 2 Write X 20H Write EA D0H
auto erase (block)
Setup auto program/ 2 Write X 40H Write PA PD program
Setup Erase/ 2 Write X 20H Write X 20H Erase (chip)
Setup Erase/ 2 Write X 60H Write EA 60H Erase (block)
Erase verify 2 Write EVA A0H Read X EVD Reset 2 Write X FFH Write X FFH
Note:
IA = Identifier address EA = Block of memory location to be erased PA = Address of memory location to be pro-
grammed
ID = Data read from location IA during device iden-
tification PD = Data to be programmed at location PA EVA = Address of memory location to be read during
erase verify. EVD = Data read from location EVA during erase
verify.
Auto modes have the build-in enchanced features. Please use the auto erase mode whenever it is.
P/N: PM0380
6
REV. 1.5, OCT 29, 1998
Page 7
MX28F2000P
COMMAND DEFINITIONS
When low voltage is applied to the VPP pin, the con­tents of the command register default to 00H, enabling read-only operation.
Placing high voltage on the VPP pin enables read/write operations. Device operations are selected by writing specific data patterns into the command register. Ta­ble 1 defines these MX28F2000P register commands. Table 2 defines the bus operations of MX28F2000P.
TABLE 2. MX28F2000P BUS OPERATIONS
OPERATION VPP(1) A0 A9 CE OE WE DQ0-DQ7 READ-ONLY Read VPPL A0 A9 VIL VIL VIH Data Out
Output Disable VPPL X X VIL VIH VIH Tri-State Standby VPPL X X VIH X X Tri-State Read Silicon ID (Mfr)(2) VPPL VIL VID(3) VIL VIL VIH Data = C2H Read Silicon ID (Device)(2) VPPL VIH VID(3) VIL VIL VIH Data = 2AH
READ/WRITE Read VPPH A0 A9 VIL VIL VIH Data Out(4)
Standby(5) VPPH X X VIH X X Tri-State Write VPPH A0 A9 VIL VIH VIL Data In(6)
NOTES:
1. VPPL may be grounded, a no-connect with a resistor tied
to ground, or < VCC + 2.0V. VPPH is the programming voltage specified for the device. When VPP = VPPL, memory contents can be read but not written or erased.
2. Manufacturer and device codes may also be accessed
via a command register write sequence. Refer to Table
1. All other addresses don't care.
3. VID is the Silicon-ID-Read high voltage.(11.5V to 13v)
4. Read operations with VPP = VPPH may access array data or Silicon ID codes.
5. With VPP at high voltage, the standby current equals ICC + IPP (standby).
6. Refer to Table 1 for valid Data-In during a write operation.
7. X can be VIL or VIH.
P/N: PM0380
7
REV. 1.5, OCT 29, 1998
Page 8
MX28F2000P
READ COMMAND
While VPP is high, for erasure and programming, memory contents can also be accessed via the read command. The read operation is initiated by writing 00H into the command register. Microprocessor read cycles retrieve array data. The device remains en­abled for reads until the command register contents are altered.
The default contents of the register upon VPP power­up is 00H. This default value ensures that no spurious alteration of memory contents occurs during the VPP power transition. Where the VPP supply is hard-wired to the MX28F2000P, the device powers up and remains enabled for reads until the command register contents are changed.
SILICON-ID-READ COMMAND
Flash-memories are intended for use in applications where the local CPU alters memory contents. As such, manufacturer- and device-codes must be accessible while the device resides in the target system. PROM programmers typically access signature codes by rais­ing A9 to a high voltage. However, multiplexing high voltage onto address lines is not a desired system­design practice.
contain an all-zero pattern, a self-timed chip erase and verify begin. The erase and verify operations are complete when the data on DQ7 is "1" at which time the device returns to the Read mode. The system is not required to provide any control or timing during these operations.
When using the Automatic Chip Erase algorithm, note that the erase automatically terminates when adequate erase margin has been achieved for the memory array(no erase verify command is required). The margin voltages are internally generated in the same manner as when the standard erase verify command is used.
The Automatic set-up erase command is a command­only operation that stages the device for automatic electrical erasure of all bytes in the array. Automatic set-up erase is performed by writing 30H to the command register.
To command automatic chip erase, the command 30H must be written again to the command register. The automatic chip erase begins on the rising edge of the WE and terminates when the data on DQ7 is "1" and the data on DQ6 stops toggling for two consecutive read cycles, at which time the device returns to the Read mode.
The MX28F2000P contains a Silicon-ID-Read opera­tion to supplement traditional PROM-programming methodology. The operation is initiated by writing 90H into the command register. Following the command write, a read cycle from address 0000H retrieves the manufacturer code of C2H. A read cycle from address 0001H returns the device code of 2AH.
SET-UP AUTOMATIC CHIP ERASE/ERASE COMMANDS
The automatic chip erase does not require the device to be entirely pre-programmed prior to excuting the Automatic set-up erase command and Automatic chip erase command. Upon executing the Automatic chip erase command, the device automatically will program and verify the entire memory for an all-zero data pattern. When the device is automatically verified to
SET-UP AUTOMATIC BLOCK ERASE/ERASE COMMANDS
The automatic block erase does not require the device to be entirely pre-programmed prior to executing the Automatic set-up block erase command and Automatic block erase command. Upon executing the Automatic block erase command, the device automati­cally will program and verify the block(s) memory for an all-zero data pattern. The system is not required to provide any controls or timing during these operations.
When the block(s) is automatically verified to contain an all-zero pattern, a self-timed block erase and verify begin. The erase and verify operations are complete when the data on DQ7 is "1" and the data on DQ6 stops toggling for two consecutive read cycles, at which time the device returns to the Read mode. The system is not required to provide any control or timing during these operations.
P/N: PM0380
8
REV. 1.5, OCT 29, 1998
Page 9
MX28F2000P
When using the Automatic Block Erase algorithm, note that the erase automatically terminates when adequate erase margin has been achieved for the memory array (no erase verify command is required). The margin voltages are internally generated in the same manner as when the standard erase verify command is used.
The Automatic set-up block erase command is a com­mand only operation that stages the device for auto­matic electrical erasure of selected blocks in the array. Automatic set-up block erase is performed by writing 20H to the command register.
To enter automatic block erase, the user must write the command D0H to the command register. Block addresses are loaded into internal register on the 2nd falling edge of WE. Each successive block load cycles, started by the falling edge of WE, must begin within 30us from the rising edge of the preceding WE. Otherwise, the loading period ends and internal auto block erase cycle starts. When the data on DQ7 is "1" and the data on DQ6 stops toggling for two consecutive read cycles, at which time auto erase ends and the device returns to the Read mode.
Refer to page 2 for detailed block address.
SET-UP AUTOMATIC PROGRAM/PROGRAM COMMANDS
RESET COMMAND
A reset command is provided as a means to safely abort the erase- or program-command sequences. Following either set-up command (erase or program) with two consecutive writes of FFH will safely abort the operation. Memory contents will not be altered. Should program-fail or erase-fail happen, two consecutive writes of FFH will reset the device to abort the operation. A valid command must then be written to place the device in the desired state.
WRITE OPERATON STATUS
TOGGLE BIT-DQ6
The MX28F2000P features a "Toggle Bit" as a method to indicate to the host sytem that the Auto Program/ Erase algorithms are either in progress or completed.
While the Automatic Program or Erase algorithm is in progress, successive attempts to read data from the device will result in DQ6 toggling between one and zero. Once the Automatic Program or Erase algorithm is completed, DQ6 will stop toggling and valid data will be read. The toggle bit is valid after the rising edge of the second WE pulse of the two write pulse sequences.
The Automatic Set-up Program is a command-only operation that stages the device for automatic pro­gramming. Automatic Set-up Program is performed by writing 40H to the command register.
Once the Automatic Set-up Program operation is per­formed, the next WE pulse causes a transition to an active programming operation. Addresses are internally latched on the falling edge of the WE pulse. Data is internally latched on the rising edge of the WE pulse. The rising edge of WE also begins the programming operation. The system is not required to provide further controls or timings. The device will automatically provide an adequate internally generated program pulse and verify margin. The automatic programming operation is completed when the data read on DQ6 stops toggling for two consecutive read cycles and the data on DQ7 and DQ6 are equivalent to data written to these two bits, at which time the device returns to the Read mode (no program verify command is required).
P/N: PM0380
DATA POLLING-DQ7
The MX28F2000P also features Data Polling as a method to indicate to the host system that the Automatic Program or Erase algorithms are either in progress or completed.
While the Automatic Programming algorithm is in op­eration, an attempt to read the device will produce the complement data of the data last written to DQ7. Upon completion of the Automatic Program algorithm an attempt to read the device will produce the true data last written to DQ7. The Data Polling feature is valid after the rising edge of the second WE pulse of the two write pulse sequences.
9
REV. 1.5, OCT 29, 1998
Page 10
While the Automatic Erase algorithm is in operation, DQ7 will read "0" until the erase operation is com­pleted. Upon completion of the erase operation, the data on DQ7 will read "1". The Data Polling feature is valid after the rising edge of the second WE pulse of two write pulse sequences.
The Data Polling feature is active during Automatic Program/Erase algorithms.
POWER-UP SEQUENCE
The MX28F2000P powers up in the Read only mode. In addition, the memory contents may only be altered after successful completion of a two-step command sequence. Power up sequence is not required.
SYSTEM CONSIDERATIONS
MX28F2000P
During the switch between active and standby condi­tions, transient current peaks are produced on the rising and falling edges of Chip Enable. The magnitude of these transient current peaks is dependent on the output capacitance loading of the device. At a minimum, a 0.1uF ceramic capacitor (high frequency, low inherent inductance) should be used on each device between VCC and GND, and between VPP and GND to minimize transient effects. In addition, to overcome the voltage drop caused by the inductive effects of the printed circuit board traces on FLASH memory arrays, a 4.7uF bulk electrolytic capacitor should be used between VCC and GND for each eight devices. The location of the capacitor should be close to where the power supply is con­nected to the array.
P/N: PM0380
10
REV. 1.5, OCT 29, 1998
Page 11
MX28F2000P
ABSOLUTE MAXIMUM RATINGS
RATING VALUE
Ambient Operating Temperature 0 Storage Temperature -65 Applied Input Voltage -0.5V to 7.0V Applied Output Voltage -0.5V to 7.0V VCC to Ground Potential -0.5V to 7.0V A9 & VPP -0.5V to 13.5V
o
C to 70oC
o
C to 125oC
NOTICE:
Stresses greater than those listed under ABSOLUTE MAXI­MUM RATINGS may cause permanent damage to the de­vice. This is stress rating only and functional operational sections of this specification is not implied. Exposure to ab­solute maximum rating conditions for extended period may affect reliability.
NOTICE:
Specifications contained within the following tables are sub­ject to change.
CAPACITANCE TA = 25oC, f = 1.0 MHz
SYMBOL PARAMETER MIN. TYP MAX. UNIT CONDITIONS
CIN Input Capacitance 14 pF VIN = 0V COUT Output Capacitance 16 pF VOUT = 0V
READ OPERATION DC CHARACTERISTICS
SYMBOL PARAMETER MIN. TYP MAX. UNIT CONDITIONS
ILI Input Leakage Current 10 uA VIN = GND to VCC
TA = 0oC TO 70oC, VCC = 5V ± 10%, VPP = GND to VCC
ILO Output Leakage Current 10 uA VOUT = GND to VCC IPP1 VPP Current 1 100 uA VPP = 5.5V ISB1 Standby VCC current 1 mA CE = VIH ISB2 1 100 uA CE = VCC + 0.3V ICC1 Operating VCC current 30 mA IOUT = 0mA, f=1MHz ICC2 50 mA IOUT = 0mA, f=11MHz VIL Input Low Voltage -0.3(NOTE 1) 0.8 V VIH Input High Voltage 2.4 VCC + 0.3 V VOL Output Low Voltage 0.45 V IOL = 2.1mA VOH Output High Voltage 2.4 V IOH = -400uA
NOTES:
1. VIL min. = -1.0V for pulse width < 50 ns. VIL min. = -2.0V for pulse width < 20 ns.
2. VIH max. = VCC + 1.5V for pulse width < 20 ns If VIH is over the specified maximum value, read operation cannot be guaranteed.
P/N: PM0380
11
REV. 1.5, OCT 29, 1998
Page 12
MX28F2000P
AC CHARACTERISTICS TA = 0
o
C to 70oC, VCC = 5V ± 10%, VPP = GND to VCC
28F2000P-70 28F2000P-90 28F2000P-12
SYMBOL PARAMETER MIN. MAX. MIN. MAX. MIN. MAX. UNIT CONDITIONS
tACC Address to Output Delay 70 90 120 ns CE=OE=VIL tCE CE to Output Delay 70 90 120 ns OE=VIL tOE OE to Output Delay 40 40 50 ns CE=VIL tDF OE High to Output Float (Note1) 0 20 0 20 0 30 ns CE=VIL tOH Address to Output hold 0 0 0 ns CE=OE=VIL
TEST CONDITIONS:
• Input pulse levels: 0.45V/2.4V
• Input rise and fall times: < 10ns
NOTE:
1. tDF is defined as the time at which the output achieves the open circuit condition and data is no longer driven.
• Output load: 1 TTL gate + 100pF (Including scope and jig)
• Reference levels for measuring timing: 0.8V, 2.0V
READ TIMING WAVEFORMS
ADDRESS
WE
CE
OE
DATA OUT
tACC
ACTIVE MODE
tCE
tOE
STANDBY MODESTANDBY MODE
tDF
tOH
DATA OUT VALID
P/N: PM0380
12
REV. 1.5, OCT 29, 1998
Page 13
MX28F2000P
COMMAND PROGRAMMING/DATA PROGRAMMING/ERASE OPERATION DC CHARACTERISTICS
SYMBOL PARAMETER MIN. TYP MAX. UNIT CONDITIONS
ILI Input Leakage Current 10 uA VIN=GND to VCC ILO Output Leakage Current 10 uA VOUT=GND to VCC ISB1 Standby VCC current 1 mA CE=VIH ISB2 1 100 uA CE=VCC ± 0.3V ICC1 (Read) Operating VCC Current 30 mA IOUT=0mA, f=1MHz ICC2 50 mA IOUT=0mA, F=11MHz ICC3 (Program) 50 mA In Programming ICC4 (Erase) 50 mA In Erase ICC5 (Program Verify) 50 mA In Program Verify ICC6 (Erase Verify) 50 mA In Erase Verify IPP1 (Read) VPP Current 100 uA VPP=12.6V IPP2 (Program) 50 mA In Programming
TA = 0oC to 70oC, VCC = 5V ± 10%, VPP = 12.0V ± 5%
IPP3 (Erase) 50 mA In Erase IPP4 (Program Verify) 50 mA In Program Verify IPP5 (Erase Verify) 50 mA In Erase Verify VIL Input Voltage -0.3 (Note 5) 0.8 V VIH 2.4 VCC+0.3V V
(Note 6) VOL Output Voltage 0.45 V IOL=2.1mA VOH 2.4 V IOH=-400uA
NOTES:
1. VCC must be applied before VPP and removed after VPP.
2. VPP must not exceed 14V including overshoot.
3. An influence may be had upon device reliability if the device is installed or removed while VPP=12V.
4. Do not alter VPP either VIL to 12V or 12V to VIL when CE=VIL.
5. VIL min. = -0.6V for pulse width < 20ns.
6. If VIH is over the specified maximum value, programming operation cannot be guranteed.
7. All currents are in RMS unless otherwise noted.(Sampled, not 100% tested.)
P/N: PM0380
13
REV. 1.5, OCT 29, 1998
Page 14
MX28F2000P
AC CHARACTERISTICS TA = 0
o
C to 70oC, VCC = 5V ± 10%, VPP =12V ± 5%
28F2000P-70 28F2000P-90 28F2000P-12
SYMBOL PARAMETER MIN. MAX. MIN. MAX. MIN. MAX. UNIT CONTIONS
tVPS VPP setup time 100 100 100 ns tOES OE setup time 100 100 100 ns tCWC Command programming cycle 70 90 120 ns tCEP WE programming pulse width 45 45 50 ns tCEPH1 WE programming pluse width High 20 20 20 ns tCEPH2 WE programming pluse width High 100 100 100 ns tAS Address setup time 0 0 0 ns tAH Address hold time 45 45 50 ns tAH1 Address hold time for DATA POLLING 0 0 0 ns tDS Data setup time 45 45 50 ns tDH Data hold time 10 10 10 ns tCESP CE setup time before DATA polling/toggle bit 100 100 100 ns tCES CE setup time 0 0 0 ns tCESC CE setup time before command write 100 100 100 ns tCESV CE setup time before verify 6 6 6 us tVPH VPP hold time 100 100 100 ns tDF Output disable time (Note 3) 20 20 30 ns tDPA DATA polling/toggle bit access time 70 90 120 ns tAETC Total erase time in auto chip erase 5(TYP.) 5(TYP.) 5(TYP.) s tAETB Total erase time in auto block erase 5(TYP.) 5(TYP.) 5(TYP.) s tAVT Total programming time in auto verify 15 300 15 300 15 300 us tBALC Block address load cycle 0.3 30 0.3 30 0.3 30 us tBAL Block address load time 100 100 100 us tCH CE Hold Time 0 0 0 ns tCS CE setup to WE going low 0 0 0 ns
NOTES:
1. CE and OE must be fixed high during VPP transition from 5V to 12V or from 12V to 5V.
2. Refer to read operation when VPP=VCC about read opera­tion while VPP 12V.
3. tDF defined as the time at which the output achieves the open circuit condition and data is no longer driven.
P/N: PM0380
14
REV. 1.5, OCT 29, 1998
Page 15
SWITCHING TEST CIRCUITS
MX28F2000P
DEVICE UNDER
TEST
CL = 100 pF including jig capacitance
SWITCHING TEST WAVEFORMS
2.4 V
0.45 V
AC TESTING: Inputs are driven at 2.4V for a logic "1" and 0.45V for a logic "0".
CL
6.2K ohm
2.0V TEST POINTS
0.8V
INPUT
Input pulse rise and fall times are <20ns.
1.8K ohm +5V
DIODES = IN3064 OR EQUIVALENT
2.0V
0.8V OUTPUT
P/N: PM0380
15
REV. 1.5, OCT 29, 1998
Page 16
AUTOMATIC PROGRAMMING TIMING WAVEFORM
MX28F2000P
One byte data is programmed. Verify in fast algorithm and additional programming by external control are not required because these operations are excuted auto­matically by internal control circuit. Programming completion can be verified by DATA polling and toggle bit
Setup auto program/ program command
Vcc 5V
12V Vpp 0V
A0 ~ A17
WE
CE
OE
Q7
tOES
tVPS
tAS
tCWC
tCEPH1
tCEP
tDS tDH tDHtDS
tCEP tCESP
checking after automatic verify starts. Device outputs DATA during programming and DATA after programming on Q7. Q0 to Q5 (Q6 is for toggle bit; see toggle bit, DATA polling, timing waveform) are in high impedance.
Auto program & DATA polling
tVPH
Address
valid
tAH1
tAVT
tCES
tDPA
Data inCommand in
DATA
tCESC
tDF
DATA
Q0~Q5
Command #40H
Data inCommand in
DATA polling
DATA
P/N: PM0380
16
REV. 1.5, OCT 29, 1998
Page 17
AUTOMATIC PROGRAMMING ALGORITHM FLOWCHART
START
Apply VppH
Write Set up auto program Command (40H)
Write Auto program Command(A/D)
MX28F2000P
Toggle Bit Checking
DQ6 not Toggled
Verify Byte Ok
NO
Auto Program Completed
Last Byte
NO
YES
NO
YES
Reset
YES
Auto Program Failed
P/N: PM0380
17
REV. 1.5, OCT 29, 1998
Page 18
AUTOMATIC CHIP ERASE TIMING WAVEFORM
MX28F2000P
All data in chip are erased. External erase verify is not required because data is erased automatically by internal control circuit. Erasure completion can be verified by DATA polling and toggle bit checking after automatic
Setup auto chip erase/ erase command
Vcc 5V
12V Vpp 0V
A0 ~ A17
WE
CE
OE
Q7
tOES
tVPS
tCWC
tCEP
tCEPH1
tDS tDH tDHtDS
Command in
tCEP tCESP
erase starts. Device outputs 0 during erasure and 1 after erasure on Q7. Q0 to Q5 (Q6 is for toggle bit; see toggle bit, DATA polling, timing waveform) are in high imped­ance.
Auto chip erase & DATA polling
tVPH
tAETC
tCES
tDPA
Command in
tCESC
tDF
Q0~Q5
Command in
Command #30H Command #30H
Command in
DATA polling
P/N: PM0380
18
REV. 1.5, OCT 29, 1998
Page 19
AUTOMATIC CHIP ERASE ALGORITHM FLOWCHART
START
Apply VppH
Write Set up auto chip Erase Command (30H)
Write Auto chip Erase Command(30H)
MX28F2000P
Toggle Bit Checking DQ6 not Toggled
YES
DATA Polling DQ7 = 1
YES
Auto Chip Erase Completed
No
No
Reset
Auto Chip Erase Failed
P/N: PM0380
19
REV. 1.5, OCT 29, 1998
Page 20
AUTOMATIC BLOCK ERASE TIMING WAVEFORM
MX28F2000P
Block data indicated by A12 to A17 are erased. External erase verify is not required because data are erased automatically by internal control circuit. Erasure comple­tion can be verified by DATA polling and toggle bit
Setup auto block erase/erase command
Vcc 5V
12V Vpp 0V
A0 ~ A11
A12 ~ A17
CE
WE
tVPS
tCS
tCH
tAS tAH
tCWC
tCEPH1
tCEPtOES
Block
address 0
tCEP
address 1
tBALC
tCEPH2
Block
checking after automatic erase starts. Device outputs 0 during erasure and 1 after erasure on Q7. Q0 to Q5 (Q6 is for toggle bit; see toggle bit, DATA polling, timing waveform) are in high impedance.
Auto block erase & DATA polling
tVPH
Block
address #
tAH1
tBAL
tAETB
tCESC
tDS tDH tDS tDH
Q7
Q0~Q5
Command inOECommand in
Command in Command in
Command #20H Command #D0H
*Refer to page 2 for detailed block address.
tDPA
DATA polling
tDF
P/N: PM0380
20
REV. 1.5, OCT 29, 1998
Page 21
AUTOMATIC BLOCK ERASE ALGORITHM FLOWCHART
ST ART
Apply VppH
Write Set up auto block Erase Command (20H)
Write Auto block Erase Command(D0H)
to Load Block Address
Load Block Address
MX28F2000P
Last Block to Erase
YES
Wait 200 us
Toggle Bit Checking DQ6 not Toggled
YES
DATA Polling
DQ7 = 1
YES
Auto Block Erase Completed
NO
NO
NO
Reset
Auto Block Erase Failed
P/N: PM0380
21
REV. 1.5, OCT 29, 1998
Page 22
COMPATIBLE CHIP ERASE TIMING WAVEFORM
All data in chip are erased. Control verification and additional erasure externally according tocompatible chip erase flowchart.
MX28F2000P
Vcc 5V
12V Vpp 0V
A0 ~ A17
WE
CE
OE
Q7
Q0~Q6
Setup chip erase/ erase command
tVPS
Verify
Address
tAH
tAS
tCWC
tCEPtOES
tDS tDH tDS tDH
Command in
Command in
Command #20H Command #20H Command #A0H
tCEPH1
tCEP
Command in
Command in
tET
tCEP
tCESV
tDH
tDS
Command in
Command in
Erase VerifyChip erase
tCES
tVA
tVPH
tCESC
tDF
Data valid
Data valid
P/N: PM0380
22
REV. 1.5, OCT 29, 1998
Page 23
COMPATIBLE BLOCK ERASE
MX28F2000P
This device can be applied to the compatible block erase algorithm shown in the following flowchart. This algorithm allows to obtain faster erase time by the block (refer to
COMPATIBLE BLOCK ERASE FLOWCHART
START
For selected block(s), All bits PGM"0"
N = 0
BLOCK ERASE FLOW
FAIL
ERSVFY FLOW
ALL BITS VERIFIED
APPLY
VPP = VCC
page2) without any voltage stress to the device nor deterioration in reliability of data.
N = N+1
N = 1024?
BLOCK ERASE FAIL
END
NO
YES
BLOCK ERASE FLOW
BLOCK ERASE
COMPLETE
VPP = VPPH
WRITE SETUP BLOCK ERASE COMMAND
WRITE BLOCK ERASE COMMAND
( LOAD FIRST SECTOR ADDRESS , 60H )
LOAD OTHER SECTORS' ADDRESS
IF NECESSARY
( LOAD OTHER SECTOR ADDRESS )
START
Apply
( 60H )
WAIT
10 ms
END
P/N: PM0380
23
REV. 1.5, OCT 29, 1998
Page 24
ERASE VERIFY FLOW
MX28F2000P
START
APPLY
VPP = VPPH
ADDRESS =
FIRST ADDRESS OF ERASED BLOCKS OR LAST VERIFY FAILED ADDRESS
INCREMENT ADDRESS
WRITE ERASE VERIFY COMMAND
NO
( A0H )
WAIT 6 us
ERSVFY
FFH ?
YES
LAST ADDRESS ?
YES
ERASE VERIFY
COMPLETE
NO
GO TO ERASE FLOW
AGAIN OR ABORT
P/N: PM0380
24
REV. 1.5, OCT 29, 1998
Page 25
COMPATIBLE BLOCK ERASE TIMING WAVEFORM
Indicated block data are erased. Control verification and additional erasure externally according to compatible block erase flowchart.
MX28F2000P
Vcc 5V
12V Vpp 0V
A0 ~ A13
A14 ~ A17
WE
CE
OE
Q0~Q6
tVPS
tOES tCEP tCEP
Q7
Command #60H Command #60H
Setup block erase/erase command
Block
address 1
tCEPH2
Command in
Command in
Block
address 0
tAS tAH
tCWC tBALC
tCEPH1
tDS tDH tDS tDH
Command in
Command in
tBAL
Block
address #
Block erase
tET
Verify
address
Verify
address
tAS
tAH
tCEP
tDS
Command in
Command in
Command #A0H
tCESV
tDH
Erase Verify
tCES
tVA
tVPH
tCESC
tDF
Data valid
Data valid
P/N: PM0380
25
REV. 1.5, OCT 29, 1998
Page 26
VPP HIGH READ TIMING WAVEFORM
Vcc 5V
12V Vpp 0V
tVPS
MX28F2000P
tVPH
A0 - A17
tCWC
WE
CE
tOES
tCEP
tCEPH1
OE
tDH
00H
Q0-Q7
tDS
Command in
VPP LOW ID CODE READ TIMING WAVEFORM
VID VIH
A9
VIL
Address valid
tACC
tCE
tOE
tCESC
tOES
tDF
tOH
Data out valid
P/N: PM0380
A0
A1 - A8
A10-A17
WE CE
OE
Q0 - Q7
VIH
tACC
tCE
tACC
tOE
Manufacturer code Device code
C2H
tOH
26
tDF
tOH
2AH
REV. 1.5, OCT 29, 1998
Page 27
VPP HIGH ID CODE READ TIMING WAVEFORM
Vcc 5V
12V Vpp 0V
tVPS
MX28F2000P
tVPH
A0
A1 - A16
WE
CE
tOES
OE
Q0-Q7
RESET TIMING WAVEFORM
Address Valid 0 or 1
tCWC
tACC
tCEP
tDS
Command in
tCEPH2
tDH
90H C2H or 2AH
tCE
tOE
Data out valid
tCESC
tOES
tDF
tOH
P/N: PM0380
Vcc 5V
12V Vpp 0V
A0 - A17
WE
CE
OE
Q0-Q7
tVPS
tOES
tCWC
tCEP
Command in
tCEPH1
tDS tDH
FFH FFH
tCEP
tDS tDH
Command in
27
REV. 1.5, OCT 29, 1998
Page 28
TOGGLE BIT, DATA POLLING TIMING WAVEFORM
Toggle bit appears in Q6, when program/erase is opperating. DATA polling appears in Q7 during pro­gramming or erase.
HIGH
WE
Vpp 12V
CE
OE
MX28F2000P
DURING P/E
Q6
Q7
DURING P
Q7
DURING E
Q0~Q5
HIGH-Z
HIGH-Z
HIGH-Z
HIGH-Z
DATA POLLING
DATA
TOGGLE BIT
DATA
DATA DATA DATA
PROGRAM/ERASE COMPLETE
DATA POLLING
DATA
P/N: PM0380
28
REV. 1.5, OCT 29, 1998
Page 29
MX28F2000P
ORDERING INFORMATION PLASTIC PACKAGE
PART NO. ACCESS TIME OPERATING STANDBY PACKAGE ERASE/PROGRAM
CURRENT CURRENT CYCLE
(ns) MAX.(mA) MAX.(uA) MIN.(time)
MX28F2000PPC-70C4 70 50 100 32 Pin DIP 10,000 MX28F2000PPC-90C4 90 50 100 32 Pin DIP 10,000 MX28F2000PPC-12C4 120 50 100 32 Pin DIP 10,000 MX28F2000PQC-70C4 70 50 100 32 Pin PLCC 10,000 MX28F2000PQC-90C4 90 50 100 32 Pin PLCC 10,000 MX28F2000PQC-12C4 120 50 100 32 Pin PLCC 10,000 MX28F2000PTC-70C4 70 50 100 32 Pin TSOP 10,000
(Normal Type)
MX28F2000PTC-90C4 90 50 100 32 Pin TSOP 10,000
(Normal Type)
MX28F2000PTC-12C4 120 50 100 32 Pin TSOP 10,000
(Normal Type)
MX28F2000PRC-70C4 70 50 100 32 Pin TSOP 10,000
(Reverse Type)
MX28F2000PRC-90C4 90 50 100 32 Pin TSOP 10,000
(Reverse Type)
MX28F2000PRC-12C4 120 50 100 32 Pin TSOP 10,000
(Reverse Type)
P/N: PM0380
29
REV. 1.5, OCT 29, 1998
Page 30
PACKAGE INFORMATION
32-PIN PLASTIC DIP
ITEM MILLIMETERS INCHES
A 42.13 max. 1.660 max. B 1.90 [REF] .075 [REF] C 2.54 [TP] .100 [TP] D .46 [Typ.] .050 [Typ.] E 38.07 1.500 F 1.27 [Typ.] .050 [Typ.] G 3.30 ± .25 .130 ± .010 H .51 [REF] .020 [REF] I 3.94 ± .25 1.55 ± .010 J 5.33 max. .210 max. K 15.22 ± .25 .600 ± .101 L 13.97 ± .25 .550 ± .010 M .25 [Typ.] .010 [Typ.]
NOTE: Each lead certerline is located within
.25mm[.01 inch] of its true position [TP] at a maximum at maximum material condition.
MX28F2000P
1732
1
A
F
D
E
16
K L
IJ
H
G
C
B
M
0~15¡
32-PIN PLASTIC LEADED CHIP CARRIER (PLCC)
ITEM MILLIMETERS INCHES
A 12.44 ± .13 .490 ± .005 B 11.50 ± .13 .453 ± .005 C 14.04 ± .13 .553 ± .005 D 14.98 ± .13 .590 ± .005 E 1.93 .076 F 3.30 ± .25 .130 ± .010 G 2.03 ± .13 .080 ± .005 H .51 ± .13 .020 ± .005 I 1.27 [Typ.] .050 [Typ.] J .71 [REF] .028 [REF] K .46 [REF] .018 [REF] L 10.40/12.94 .410/.510
(W) (L) (W) (L) M .89R .035R N .25[Typ.] .010[Typ.]
NOTE: Each lead certerline is located within
.25mm[.01 inch] of its true position [TP] at a maximum at maximum material condition.
A
B
4
5
9
13
14
F
G
H
I
1
32
30
29
25
CD
21
17
K
L
20
E
N
M
J
P/N: PM0380
30
REV. 1.5, OCT 29, 1998
Page 31
32-PIN PLASTIC TSOP
ITEM MILLIMETERS INCHES
A 20.0 ± .20 .078 ± .006 B 18.40 ± .10 .724 ± .004 C 8.20 max. .323 max. D 0.15 [Typ.] .006 [Typ.] E .80 [Typ.] .031 [Typ.] F .20 ± .10 .008 ± .004 G .30 ± .10 .012 ± .004 H .50 [Typ.] .020 [Typ.] I .45 max. .018 max. J 0 ~ .20 0 ~ .008 K 1.00 ± .10 .039 ± .004 L 1.27 max. .050 max. M .50 .020 N 0 ~5° .500
NOTE: Each lead certerline is located within
.25mm[.01 inch] of its true position [TP] at a maximum at maximum material condition.
MX28F2000P
A B
C
O
M
D
E
F
H
G
N
KL
J
I
P/N: PM0380
31
REV. 1.5, OCT 29, 1998
Page 32
MX28F2000P
Note. Revision History
Revision # Description Page Date
1.3 Command description of dummy mode a added, TSOP pin configuration diagram rotated 180°, the flow chart of block erase corrected, fast acces time 150ns removed.
1.4 The speed performanes is featured up to 70ns as the new update of fast P1,14,29 Sep/18/98 access time
1.5 To corret typing error P12,14,16, OCT/29/98
27,29
P/N: PM0380
32
REV. 1.5, OCT 29, 1998
Page 33
MX28F2000P
MACRONIX INTERNATIONAL CO., LTD.
HEADQUARTERS:
TEL:+886-3-578-8888 FAX:+886-3-578-8887
EUROPE OFFICE:
TEL:+32-2-456-8020 FAX:+32-2-456-8021
JAPAN OFFICE:
TEL:+81-44-246-9100 FAX:+81-44-246-9105
SINGAPORE OFFICE:
TEL:+65-747-2309 FAX:+65-748-4090
TAIPEI OFFICE:
TEL:+886-3-509-3300 FAX:+886-3-509-2200
MACRONIX AMERICA, INC.
TEL:+1-408-453-8088 FAX:+1-408-453-8488
CHICAGO OFFICE:
TEL:+1-847-963-1900 FAX:+1-847-963-1909
http : //www.macronix.com
MACRONIX INTERNATIONAL CO., LTD. reserves the rignt to change product and specifications without notice.
33
Loading...