Datasheet MVS5410-10, MVS5410-02 Datasheet (Perkinelmer)

Page 1
.
MVS-5410
Machine Vision Strobe
Description
The PerkinElmer MVS 5410 Machine Vision Strobe is a source of short duration, high intensity light pulses used to “freeze motion” as a visual aid for machine vision applications.
The MVS 5410 is a self contained, AC-powered unit packaged in a rugged metal enclosure designed for industrial applications. It is fitted with a polycarbonate window for safety and an adjustable bracket for maxi­mum convenience and flexibility in mounting. Its output may be external­ly triggered or controlled by an inter­nal source which is adjustable from the convenient front control panel. Input cable connections and cooling vents are protectively located on the rear panel.
www.perkinelmer.com/opto
DATASHEET
Lighting
Imaging
Telecom
Machine Vision Illumination Systems
Features
CE Certified to EMC and Safety directives
Internal or external triggering
Exceptional lamp stability
Long lamp life
Up to 24,000 flashes per minute (400Hz)
Microsecond flash durations
Universal power input (90-230VAC, 50/60Hz)
Adjustable mounting
Easy access to control panel
Line power is supplied through a line cord receptacle and a country– specific line cord which is included. External trigger input is applied through a five pin DIN connector. A control cable with mating connector is supplied with each unit.
Page 2
Input voltage Input current Power to Lamp External trigger:
Pulse
Current Duty cycle Flash delay
Internal trigger
90-230 VAC 50/60 Hz 135 W rms maximum 100 W rma maximum
+5 volt TTL pulse, 10-100 µsec into an opto-isolator with internal 150 ohm nominal resistor 20 mA up to 90% 18µsec max from leading edge of trigger pulse Variable via 10-turn potentiometer
For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto.
All values are nominal; specifications subject to change without notice.
© 2001 PerkinElmer inc. All rights reserved. 0601
.
USA: PerkinElmer Optoelectronics 35 Congress Street Salem, MA 01970 Toll Free: (800) 950-3441 (USA) Phone: (978) 745-3200 Fax: (978) 745-0894
Europe: PerkinElmer Optoelectronics
Wenzel-Jaksch-Str. 31, D-65199 Weisbaden, Germany Phone: +49 (0) 611-492-437 Fax: +49 (0)611-492-159
Asia: PerkinElmer Optoelectronics 47 Ayer Rajah Crescent #06-12 Singapore 139947 Phone: +65 775 2022 Fax: +65 775 1008
Spectral bandwidth Flashlamp life (5) Flash duration (1) Intensity level
MVS-5410-10
300 to 1100+ nm >10
8
flashes 20 microseconds Adjustable from 35% to 100%
MVS-5410-02 300 to 1100+ nm >10
8
flashes 20 microseconds Adjustable from 35% to 100%
Optical Specifications
Electrical Specifications
MVS-5410 Strobe
www.perkinelmer.com/opto
ooooooo
o
ooooooo
ooooooo
o
ooooooo
o
ooooooo
ooooooo
o
ooooooo
o
ooooooo
ooooooo
o
ooooooo
o
ooooooo
ooooooo
o
O
10.75 (273)
0.281 DIA. HOLE, 2 PLACES FOR MOUNTING
10.35 (263)
7.50 (191)
Intensity
Trigger
RATE
INT
EXT
POWER
STBV
6.30
(160)
6.78
(172)
9.71
(247)
12.25 (311)
Air Exhaust
Cooling Fan
AC
Input
On/Off Switch
Control
Input
Rear Panel
DIMENSIONS ARE IN
INCHES (MILLIMETERS)
WEIGHT: 7.2 LBS (3.27kg)
Mechanical Specifications
Note 1: Energy per flash is constant up to 100Hz; total output power is constant from 100Hz to 200Hz. (Power = Energy x Flashrate) Note 2: Energy per flash is constant up to 200Hz; total output power is constant from 200Hz to 400Hz. (Power = Energy x Flashrate) Note 3: At maximum intensity. Flash to Flash Variation ±5% Note 4: Lux = Lumen-second/meter
2
Note 5: Where light output is not less than 50% of maximum value.
Distance
1 foot 2 feet 3 feet
Area Illuminated
15” x 15” 30” x 30” 45” x 45”
Photometric
38 lux-sec 10 lux-sec 4 lux-sec
Radiometric
32 µJ/cm
2
9 µJ/cm
2
4 µJ/cm
2
Area Illuminated
15” x 15” 30” x 30” 45” x 45”
Photometric
13 lux-sec
3.5 lux-sec
1.5 lux-sec
Radiometric
12 µJ/cm
2
3 µJ/cm
2
1.5 µJ/cm
2
Illumination Characteristics
Operating temperature Storage temperature Shock and vibration
-10 to +110°F (-23 to +43°C)
-40 to +194°F (-40 to +90°C)
1.5G, 50 to 200 Hz per MIL-STD-810C
Environmental Specifications
Controls
Flash rate intensity (1 turn potentiometer) internal/external Flash rate (10 turn potentiometer) internal only Internal/External trigger switch Flash standby (stopps flashlamps operation) internal/external AC Power On/OFF switch (back side of unit)
Indicators
Trigger light AC power light
CAUTION Some glass flashlamps are under high internal pressure, and, if bro­ken, could result in glass particles being blown into the face and hand areas. To prevent injury, wear suit­able protective devices such as safety glasses and/or face mask and gloves.
Some types of pulsed lamps gen­erate intense ultraviolet radiation which, if not properly shielded from personnel in the area, will cause burns to any exposed skin and especially to the eyes. Do not expose any skin area or the eyes to the direct or reflected radiation of an operating lamp. If you have to view an operating lamp, always use protective covering for exposed skin area and ultraviolet­attenuating goggles for the eyes.