LOW PROFILE T-1
SOLID STATE LAMPS
.130 (3.30)
.115 (2.92)
C
L
.160 (4.06)
.140 (3.56)
.045 (1.143)
1.00 (25.4)
MIN
.075 (1.91)
.025 (.64)
.060 (1.52)
.050 (1.27)
CATHODE
REF FLAT
.160 (4.06)
.150 (3.81)
DIA
.018 (.460)
.012 (.305)
SQ. TYP. (2X)
ANODE
PACKAGE DIMENSIONS
RED DIFFUSED MV5077C YELLOW DIFFUSED MV5377C
GREEN DIFFUSED MV5477C HER DIFFUSED MV5777C
DESCRIPTION
These solid state indicators offer a variety of color
selection. The High Efficiency Red, Green and Yellow
devices are made with a gallium arsenide phosphide
LED on gallium phosphide substrate. All are encapsulated in
epoxy packages. Their low profile, small size (approximately T-1
size), good viewing angle, and small square leads contribute to
their versatility as all purpose indicators.
FEATURES
• Copper leads
• Solid-state reliability
2001 Fairchild Semiconductor Corporation
DS300038 12/19/01 1 OF 4 www.fairchildsemi.com

Part Number Symbol MV5077C MV5377C MV5477C MV5777C Condition
Luminous Intensity (mcd) IF= 20mA
Minimum I
V
0.3 1.0 1.0 1.0
Typical 1.8 7.0 7.0 7.0
Forward Voltage (V) IF= 20mA
Typical V
F
1.6 2.1 2.2 2.0
Maximum 2.0 3.0 3.0 3.0
Spectral Line Half Width (nm) 20 35 35 45 IF= 20mA
Peak Wavelength (nm) λp 660 585 565 635 I
F = 20mA
Viewing Angle (Total) (°) 2θ 1/2 140 140 140 140 IF = 20mA
ELECTRICAL / OPTICAL CHARACTERISTICS
(TA =25°C)
1. The leads of the device were immersed in molten solder at 260°C, to a point 1/16 inch (1.6 mm) from the body of the device per
MIL-S-750, with a dwell time of 5 seconds.
www.fairchildsemi.com 2 OF 4 12/19/01 DS300038
Parameter Symbol Rating Units
Power Dissipation
P
D
105 mW
Derate linearly from 25°C -1.14 mW/°C
Continuous Forward Current (MV5377C) I
F
35 mA
Peak Forward Current - (µsec pulse 0.3% duty cycle)
I
FM
(MV5477C=90 mA) (MV5377C=60 mA)
35 mA
Reverse Voltage (IR= 100 µA) V
R
5V
Lead Soldering Time at 260°C (See Note 1) T
SOL
5 sec
Operating Temperature T
OPR
-55 to +100 °C
Storage Temperature T
STG
-55 to +100 °C
ABSOLUTE MAXIMUM RATING
(TA =25°C Unless Otherwise Specified)
LOW PROFILE T-1
SOLID STATE LAMPS

TYPICAL PERFORMANCE CURVES
(TA=25°C)
DS300038 12/19/01 3 OF 4 www.fairchildsemi.com
LOW PROFILE T-1
SOLID STATE LAMPS
Fig. 1 Forward Current vs. Forward Voltage
100
90
80
70
60
50
40
30
20
- FORWARD CURRENT (mA)
F
I
10
0
RED
1234
VF - FORWARD VOLTAGE (V)
YELLOW
HER
GREEN
-40˚
Fig. 3 Spatial Distribution
0˚
-10˚
-20˚
-30˚
Fig. 2 Luminous Intensity vs. Forward Current
40
30
20
10
LUMNOUS INTENSITY
0
020406080
IF - FORWARD CURRENT (mA)
10˚
20˚
30˚
40˚
-50˚
-60˚
-70˚
-80˚
-90˚
100
Fig. 4 Relative Intensity vs. Peak Wavelength
120
100
80
60
40
RELATIVE INTENSITY (%)
20
0 20406080100020406080
REL. LUMINOUS INTENSITY (%)
GREEN YELLOW
HER
50˚
60˚
70˚
80˚
90˚
RED
0
520 540 560 580 600 620 640 660 680 690
λ - WAVELENGTH (nm)

DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE
RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical
implant into the body,or (b) support or sustain life,
and (c) whose failure to perform when properly
used in accordance with instructions for use provided
in labeling, can be reasonably expected to result in a
significant injury of the user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.fairchildsemi.com 4 OF 4 12/19/01 DS300038
LOW PROFILE T-1