Datasheet MS5561-C Datasheet (ntersema)

Page 1
MS5561-C
MICRO ALTIMETER
DESCRIPTION
The MS5561 is a SMD-hybrid device including a precision piezo-resistive pressure sensor and an ADC-Interface IC. It uses a three-wire serial interface for communication. The module dimensions of 4.75 mm x 4.25 mm and a height of only 1.6 mm allows for up-to-date SMD design. It provides a 16 bit data word from a pressure and temperature dependent voltage. The MS5561 is a low power, low voltage device with automatic power down (ON/OFF) switching. A 3-wire interface is used for all communications with a micro-controller.
10 - 1100 mbar / 1 – 110 kPa absolute pressure range
High accuracy temperature measurement
Integrated miniature pressure sensor module
Thin design of 1.6 mm
Piezo-resistive silicon micro-machined sensor
6 coefficients for software compensation stored on-
chip
16 bit ADC, sigma delta converter
3-wire serial interface
1 system clock line (32.768 kHz)
Low voltage and low power consumption
RoHS-compatible & Pb-free
*
FEATURES APPLICATIONS
Pressure resolution 0.1 mbar
Operating temperature -40°C to +85°C
Supply voltage 2.2 V to 3.6 V
Low supply current, typ. 4 µA
Standby current < 0.1 µA
Calibrated temperature and pressure sensor for
nd
order compensation
2
ESD protected, HBM 4 kV
Mobile phones
GPS receivers
Altimeter applications
Personal Navigation Devices (PND)
Digital cameras with altimeter function
BLOCK DIAGRAM
SENSOR
+IN
-IN
SGND
Input MUX
dig.
ADC
Filter
Sensor Interface IC
Fig. 1: Block diagram MS5561
Digital
Interface
Memory (PROM)
64 bits
VDD
MCLK
DIN
DOUT
SCLK
GND
*
The European RoHS directive 2002/95/EC (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) bans
the use of lead, mercury, cadmium, hexavalent chromium and polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
DA5561_03 January 5, 2009 1
000055611126 – ECN1158
www.sensorway.cn
Page 2
PIN CONFIGURATION
Fig. 2: Pin configuration of MS5561
Pin Name Pin Type Function
SCLK 1 I Serial data clock
GND 2 G Ground
PV (1) 3 N Negative programming voltage PEN (1) 4 I Programming enable
VDD 5 P Positive supply voltage
MCLK 6 I Master clock (32.768 kHz) DIN 7 I Serial data input
DOUT 8 O Serial data output
NOTE
1) Pin 3 (PV) and PIN 4 (PEN) are only used by the manufacturer for calibration purposes and should not be connected.
ABSOLUTE MAXIMUM RATINGS
Parameter Symbol Conditions Min Max Unit Notes
Supply voltage VDD Ta = 25 °C -0.3 4 V Storage temperature TS -40 +85 °C 1
Overpressure P Ta = 25 °C 10 bar
NOTE
1) Storage and operation in an environment of dry and non-corrosive gases.
DA5561_03 January 5, 2009 2
000055611126 – ECN1158
www.sensorway.cn
Page 3
RECOMMENDED OPERATING CONDITIONS
(Ta = 25°C, VDD = 3.0 V unless noted otherwise)
Parameter Symbol Conditions Min. Typ Max Unit
Operating pressure range p 10 1100
Supply voltage VDD 2.2 3.0 3.6 V
Supply current, average (1) during conversion (2) standby (no conversion)
Current consumption into MCLK (3) Operating temperature range
Conversion time t
I
avg
I
sc
Iss
T -40 +25 +85 °C
MCLK = 32.768 kHz 35 ms
conv
VDD = 3.0 V
4 1
0.1
MCLK = 32.768 kHz 0.5
External clock signal (4) MCLK 30.000 32.768 35.000 kHz
Duty cycle of MCLK 40/60 50/50 60/40 %
Serial data clock SCLK 500 kHz
NOTES
1) Under the assumption of one conversion every second. Conversion means either a pressure or a temperature measurement started by a command to the serial interface of MS5561.
2) During conversion the sensor will be switched on and off in order to reduce power consumption; the total on time within a conversion is about 2 ms.
3) This value can be reduced by switching off MCLK while MS5561 is in standby mode.
4) It is strongly recommended that a crystal oscillator be used because the device is sensitive to clock jitter. A square-wave form of the clock signal is a must.
mbar
abs.
µA
mA
µA
µA
DA5561_03 January 5, 2009 3
000055611126 – ECN1158
www.sensorway.cn
Page 4
ELECTRICAL CHARACTERISTICS
DIGITAL INPUTS
(T = -40°C .. 85°C, VDD = 2.2 V .. 3.6 V)
Parameter Symbol Conditions Min Typ Max Unit
Input High Voltage VIH 80% VDD 100% VDD
Input Low Voltage VIL 0% VDD 20% VDD V
Signal Rise Time tr 200 ns
Signal Fall Time tf 200 ns
DIGITAL OUTPUTS
(T = -40°C .. 85°C, VDD = 2.2 V .. 3.6 V)
Parameter Symbol Conditions Min Typ Max Unit
Output High Voltage VOH I
Output Low Voltage VOL I
Signal Rise Time tr 200 ns
Signal Fall Time tf 200 ns
AD-CONVERTER
Parameter Symbol Conditions Min Typ Max Unit
Resolution 16 bit
Linear Range 4’000 40’000 LSB
Conversion Time MCLK = 32.768 kHz 35 ms
INL Within linear range -5 +5 LSB
= 0.6 mA 80% VDD 100% VDD
source
= 0.6 mA 0% VDD 20% VDD V
sink
(T = -40°C .. 85°C, VDD = 2.2 V .. 3.6 V)
V
V
DA5561_03 January 5, 2009 4
000055611126 – ECN1158
www.sensorway.cn
Page 5
PRESSURE OUTPUT CHARACTERISTICS
With the calibration data stored in the interface IC of the MS5561, the following characteristics can be achieved:
(VDD = 3.0 V unless noted otherwise)
Parameter Conditions Min Typ Max Unit Notes
Resolution
Absolute Pressure Accuracy
Relative Pressure Accuracy
p = 300 .. 1000 mbar
= 25°C
T
a
p = 750 .. 1100 mbar
= 25°C
T
a
p = 750 .. 1100 mbar
= 25°C
T
a
T = 0 .. +50°C Relative Pressure Error over Temperature
p = 300 .. 1000 mbar
T = -40 .. +85°C
p = 300 .. 1000 mbar Long-term Stability 12 months -1 mbar 5 Maximum Error over Supply
Voltage
VDD = 2.2 .. 3.6 V
p = const.
NOTES
1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure values due to noise of the ADC.
2) Maximum error of pressure reading over the pressure range.
3) Maximum error of pressure reading over the pressure range after offset adjustment at one pressure point.
4) With the second-order temperature compensation as described in Section “FUNCTION". See next section for typical operating curves.
5) The long-term stability is measured with non-soldered devices.
0.1 mbar 1
-1.5 +1.5 mbar 2
-0.5 +0.5 mbar 3
-1 +1 mbar 4
-2 +3 mbar 4
-1.6 +1.6 mbar
TEMPERATURE OUTPUT CHARACTERISTICS
This temperature information is not required for most applications, but it is necessary to allow for temperature compensation of the pressure output.
(VDD = 3.0 V unless noted otherwise)
Parameter Conditions Min Typ Max Unit Notes
Resolution 0.005 0.01 0.015 °C
Accuracy
Maximum Error over Supply Voltage
NOTES
1) With the second-order temperature compensation as described in Section “FUNCTION". See next section for typical operating curves.
2) At Ta = 25 °C
T = 20°C -0.8 0.8 °C
T = -40 .. +85°C -2 +3 °C 1
VDD = 2.2 .. 3.6 V -0.2 + 0.2 °C 2
DA5561_03 January 5, 2009 5
000055611126 – ECN1158
www.sensorway.cn
Page 6
TYPICAL PERFORMANCE CURVES
ADC-value D1 vs Pressure (typical)
22000
20000
18000
16000
14000
ADC-value D1 (LSB)
12000
10000
8000
6000
0 100 200 300 400 500 600 700 800 900 1000 1100
ADC-value D2 vs Temperature (typical)
40000
35000
Pressure (mbar)
-40°C 25°C
85°C
30000
25000
ADC-value D2 (LSB)
20000
15000
-40 -2 0 0 20 40 60 80
Absolute Pressure Accuracy after Calibration, 2nd order compensation
4
3
2
1
0
-1
Pressure error (mbar)
-2
-3
Temperature (°C)
85°C
60°C
25°C
0°C
-40°C
-4 0 100 200 300 400 500 600 700 800 900 1000 1100
DA5561_03 January 5, 2009 6
000055611126 – ECN1158
Pressure (mbar)
www.sensorway.cn
Page 7
Temperature Error Accuracy vs temperature (typical)
15
10
Temperature error (standard calculation)
5
Temperature error (°C)
0
-5
-40 -20 0 20 40 60 80
Temperature (°C)
Pressure Error Accuracy vs temperature (typical)
18
16
14
12
10
8
6
4
2
Pressure error (mbar)
0
-2
-4
-6
-8
-40 -20 0 20 40 60 80
Temperature (°C)
Temperature error (with 2nd order calculation)
Perror(1000,1st order)
Perror(1000,2nd order)
Perror(800,1st order)
Perror(800,2nd order)
Perror(300,1st order)
Perror(300,2nd order)
DA5561_03 January 5, 2009 7
000055611126 – ECN1158
www.sensorway.cn
Page 8
Pressure error vs supply voltage (typical)
1
0.8
0.6
0.4
0.2
0
2.2 2.4 2.6 2.8 3 3.2 3.4 3.6
-0.2
Pressure error (mbar)
-0.4
-0.6
-0.8
-1
Temperature error vs supply voltage (typical)
Voltage (V)
1000mbar
800mbar
300mbar
0.15
0.1
0.05
0
2.2 2.4 2.6 2.8 3 3.2 3.4 3.6
Temperature error (°C)
-0.05
-0.1
-0.15
Voltage (V)
DA5561_03 January 5, 2009 8
000055611126 – ECN1158
www.sensorway.cn
Page 9
FUNCTION
GENERAL
The MS5561 consists of a piezo-resistive sensor and a sensor interface IC. The main function of the MS5561 is to convert the uncompensated analogue output voltage from the piezo-resistive pressure sensor to a 16-bit digital value, as well as providing a 16-bit digital value for the temperature of the sensor.
Measured pressure (16-bit) “D1” Measured temperature (16-bit) “D2”
As the output voltage of a pressure sensor is strongly dependent on temperature and process tolerances, it is necessary to compensate for these effects. This compensation procedure must be performed by software using an external microcontroller.
Sensor
D1
D2
Word1..4
Calculation
in external
micro-
controller
Pressure
Temperature
For both pressure and temperature measurement the same ADC is used (sigma delta converter):
for the pressure measurement, the differential output voltage from the pressure sensor is converted
for the temperature measurement, the sensor bridge resistor is sensed and converted
During both measurements the sensor will only be switched on for a very short time in order to reduce power consumption. As both, the bridge bias and the reference voltage for the ADC are derived from VDD, the digital output data is independent of the supply voltage.
FACTORY CALIBRATION
Every module is individually factory calibrated at two temperatures and two pressures. As a result, 6 coefficients necessary to compensate for process variations and temperature variations are calculated and stored in the 64­bit PROM of each module. These 64-bit (partitioned into four words of 16-bit) must be read by the microcontroller software and used in the program converting D1 and D2 into compensated pressure and temperature values.
PRESSURE AND TEMPERATURE MEASUREMENT
The sequence of reading pressure and temperature as well as of performing the software compensation is depicted in Fig. 3 and Fig. 5. First Word1 to Word4 have to be read through the serial interface. This can be done once after reset of the microcontroller that interfaces to the MS5561. Next, the compensation coefficients C1 to C6 are extracted using bit-wise logical- and shift-operations (refer to Fig. 4 for the bit-pattern of Word1 to Word4). For the pressure measurement, the microcontroller has to read the 16-bit values for pressure (D1) and temperature (D2) via the serial interface in a loop (for instance every second). Then, the compensated pressure is calculated out of D1, D2 and C1 to C6 according to the algorithm in Fig. 3 (possibly using quadratic temperature compensation according to Fig. 5). All calculations can be performed with signed 16-bit variables. Results of multiplications may be up to 32-bit long (+sign). In the flow according to Fig. 3 a division follows each multiplication. This division can be performed by bit-wise shifting (divisors are to the power of 2). It is ensured that the results of these divisions are less than 65536 (16 bit).
For the timing of signals to read out Word1 to Word4, D1, and D2 please refer to the paragraph “Serial Interface”.
DA5561_03 January 5, 2009 9
000055611126 – ECN1158
www.sensorway.cn
Page 10
System
Start
Read calibration data (factory calibrated) from
PROM of MS5561
Word1, Word2, Word3 and Word4 (4x16 Bit)
initialisation
Convert calibration data into coefficients:
(see bit pattern of Word1-Word4)
C1: Pressure sensitivity (15 Bit) C2: Pressure offset (12 Bit) C3: Temperature coefficient of pressure sensitivity (10 Bit) C4: Temperature coefficient of pressure offset (10 Bit) C5: Reference Temperature (11 Bit) C6: Temperature coefficient of the temperature (6 Bit)
Read digital pressure value from MS5561
D1 (16 Bit)
Read digital temperature value from MS5561
D2 (16 Bit)
Calculate calibration temperature
UT1 = 8*C5+20224
Basic equations:
Example:
Word1 = 46940 Word2 = 40217 Word3 = 25172 Word4 = 47212
SENST1 OFFT1 TCS TCO T
ref
TEMPSENS
C1 = 23470 C2 = 1324 C3 = 737 C4 = 393 C5 = 628 C6 = 25
D1 = 16460
D2 = 27856
UT1 = 25248
Calculate actual temperature
Difference between actual temperature and reference temperature:
Pressure and temperature measurement
dT = D2 - UT1
Actual temperature:
TEMP = 200 + dT*(C6+50)/210
(0.1°C resolution)
Calculate temperature compensated pressure
Offset at actual temperature:
OFF = C2*4 + ((C4-512)*dT)/212
Sensitivity at actual temperature:
SENS = C1 + (C3*dT)/210 + 24576
X = (SENS * (D1-7168))/214 - OFF
Temperature compensated pressure:
P = X*10/25 + 250*10 (0.1 mbar resolution)
dT(D2) = D2 - T
TEMP(D2) = 20°+dT(D2)*TEMPSENS
OFF(D2) = OFFT1+TCO*dT(D2)
SENS(D2) = SENST1+TCS*dT(D2)
P(D1,D2) = D1*SENS(D2)-OFF(D2)
ref
dT = 2608
TEMP = 391 = 39.1 °C
OFF = 5220
SENS = 49923
X = 23093
P = 9716 = 971.6 mbar
Display pressure and temperature value
Fig. 3: Flow chart for pressure and temperature reading and software compensation.
NOTES
1) Readings of D2 can be done less frequently, but the display will be less stable in this case.
2) For a stable display of 0.1 mbar resolution, it is recommended to display the average of 8 subsequent pressure values.
DA5561_03 January 5, 2009 10
000055611126 – ECN1158
www.sensorway.cn
Page 11
Word1 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB10
Word2 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB5 DB4 DB3 DB2 DB1 DB0
Word3 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB11 DB10 DB9 DB8 DB7 DB6
Word4 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB5 DB4 DB3 DB2 DB1 DB0
C5/II (10 bit) C6 (6 bit)
C4 (10 bit) C2/I (6 bit)
C3 (10 bit) C2/II (6 bit)
C1 (15 bit)
Fig. 4: Arrangement (bit pattern) of calibration data in Word1 to Word4.
SECOND-ORDER TEMPERATURE COMPENSATION
In order to obtain best accuracy over the whole temperature range, it is recommended to compensate for the non-linearity of the output of the temperature sensor. This can be achieved by correcting the calculated temperature and pressure by a second order correction factor. The second-order factors are calculated as follows:
C5/I 1 bit
TEMP < 200
yes
Low temperatures
T2 = 11*(C6+24)*(200 - TEMP)*(200 – TEMP) / 220
P2 = 3 *T2 * (P - 3500)/2
14
Fig. 5: Flow chart for calculating the temperature and pressure to the optimum accuracy.
200 TEMP 450
yes
No correction
T2 = 0
P2 = 0
T2 = 3*(C6+24)*(450 - TEMP)*(450 – TEMP) / 220
P2 = T2 * (P - 10000)/2
Calculate pressure and temperature
TEMP = TEMP – T2
P = P – P2
TEMP > 450
yes
High temperatures
13
DA5561_03 January 5, 2009 11
000055611126 – ECN1158
www.sensorway.cn
Page 12
SERIAL INTERFACE
The MS5561 communicates with microprocessors and other digital systems via a 3-wire synchronous serial interface as shown in Fig. 1. The SCLK (Serial clock) signal initiates the communication and synchronizes the data transfer with each bit being sampled by the MS5561 on the rising edge of SCLK and each bit being sent by the MS5561 on the rising edge of SCLK. The data should thus be sampled by the microcontroller on the falling edge of SCLK and sent to the MS5561 with the falling edge of SCLK. The SCLK-signal is generated by the microprocessor’s system. The digital data provided by the MS5561 on the DOUT pin is either the conversion result or the software calibration data. In addition, the signal DOUT (Data out) is also used to indicate the conversion status (conversion-ready signal, see below). The selection of the output data is done by sending the corresponding instruction on the pin DIN (Data input).
Following is a list of possible output data instructions:
Conversion start for pressure measurement and ADC-data-out “D1” (Figure 6a) Conversion start for temperature measurement and ADC-data-out “D2” (Figure 6b) Calibration data read-out sequence for Word1 (Figure 6c) Calibration data read-out sequence for Word2 (Figure 6d) Calibration data read-out sequence for Word3 (Figure 6c) Calibration data read-out sequence for Word4 (Figure 6d) RESET sequence (Figure 6e)
Every communication starts with an instruction sequence at pin DIN. Fig. 6 shows the timing diagrams for the MS5561. The device does not need a ‘Chip select’ signal. Instead, there is a START sequence (3-bit high) before each SETUP sequence and STOP sequence (3-bit low) after each SETUP sequence. The SETUP sequence consists in 4-bit that select a reading of pressure, temperature or calibration data. In case of pressure­(D1) or temperature- (D2) reading the module acknowledges the start of a conversion by a low to high transition at pin DOUT during the last bit of the STOP sequence. Two additional clocks at SCLK are required after the acknowledge signal. Then SCLK is to be held low by the microcontroller until a high to low transition on DOUT indicates the end of the conversion. This signal can be used to create an interrupt in the microcontroller. The microcontroller may now read out the 16 bit word by giving another 17 clocks on the SLCK pin. It is possible to interrupt the data READOUT sequence with a hold of the SCLK signal. It is important to always read out the last conversion result before starting
a new conversion.
The RESET sequence is special as the module in any state recognizes its unique pattern. By consequence, it can be used to restart if synchronization between the microcontroller and the MS5561 has been lost. This sequence is 21-bit long. The DOUT signal might change during that sequence (see Fig. 6e).
It is recommended to send the RESET sequence before each CONVERSION sequence to avoid hanging up the protocol permanently in case of electrical interference.
Conversion start for pressure measurement and ADC-data-out "D1":
end of conversion
SCLKDOUTDIN
start of conversion
sequence: START+P-measurement
Bit7
Bit6Bit5Bit4Bit3Bit2Bit1Bit0
Start-bit Stop-bit
Setup-bits
Bit8 Bit9
conversion
(33ms)
ADC-data out
MSB
DB7
DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB7
ADC-data out
LSB
DB6
DB5 DB4 DB3 DB2 DB1 DB0
Fig. 6a: D1 ACQUISITION sequence.
DA5561_03 January 5, 2009 12
000055611126 – ECN1158
www.sensorway.cn
Page 13
Conversion start for temperature measurement and ADC-data-out "D2":
end of conversion
SCLKDOUTDIN
sequence: START+T-measurement
Start-bit Stop-bitSetup-bits
start of conversion
Bit7
Bit6Bit5Bit4Bit3Bit2Bit1Bit0
Bit8 Bit9
conversion
(33ms)
DB7
ADC-data out
MSB
DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
ADC-data out
LSB
Fig. 6b: D2 ACQUISITION sequence.
Calibration data read out sequence for word 1/ word 3:
SCLKDOUTDIN
sequence: coefficient read + address
Start-bit
Setup-bits
coefficient-data out
DB7
DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Bit7
Bit6Bit5Bit4Bit3Bit2Bit1Bit0
Bit8 Bit9
Bit10 Bit11
Stop-bit
address word 1
address word 3
MSB
coefficient-data out
LSB
Fig. 6c: Word1, Word3 READING sequence.
Calibration data read out sequence for word 2/ word 4:
SCLKDOUTDIN
sequence: coefficient read + address
Start-bit
Setup-bits
coefficient-data out
DB7
DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Bit7
Bit6Bit5Bit4Bit3Bit2Bit1Bit0
Bit8 Bit9
Bit10 Bit11
Stop-bit
address word 2
address word 4
MSB
coefficient-data out
LSB
Fig. 6d: W2, W4 READING sequence.
RESET - sequence:
SCLKDOUTDIN
sequence: RESET
Bit7
Bit6Bit5Bit4Bit3Bit2Bit1Bit0 Bit8 Bit9 Bit10 Bit11 Bit12 Bit13Bit14 Bit15
Bit16Bit17 Bit18Bit19 Bit20
Fig. 6e: RESET sequence (21 bit).
DA5561_03 January 5, 2009 13
000055611126 – ECN1158
www.sensorway.cn
Page 14
APPLICATION INFORMATION
GENERAL
The advantage of combining a pressure sensor with a directly adapted integrated circuit is to save other external components and to achieve very low power consumption. The main application field for this system includes portable devices with battery supply, but its high accuracy and resolution make it also suited for industrial and automotive applications. The possibility to compensate the sensor by software allows the user to adapt it to his particular application. Communication between the MS5561 and the widely available microcontrollers is realized over an easy-to-use 3-wire serial interface. Customers may select which microcontroller system to be used, and there are no specific standard interface cells required, which may be of interest for specially designed 4 bit­microcontroller applications. For communication via SPI interface please refer to application note AN510 that may be downloaded from the Intersema website.
CALIBRATION
The MS5561 is factory calibrated. The calibration data is stored inside the 64 bit PROM memory.
SOLDERING
Please refer to the application note AN808 for all soldering issues.
HUMIDITY, WATER PROTECTION
This module is designed for the integration into portable devices and sufficiently protected against humidity. A silicone gel for enhanced protection against humidity covers the membrane of the pressure transducer. The module must not be used for under water applications.
LIGHT SENSITIVITY
The MS5561 is protected against sunlight by its metal cap. It is, however, important to note that the sensor may still be slightly sensitive to sunlight, especially to infrared light sources. This is due to the strong photo effect of silicon. As the effect is reversible there will be no damage, but the user has to take care that in the final product the sensor cannot be exposed to direct light during operation.
DECOUPLING CAPACITOR
Particular care must be taken when connecting the device to power supply. A 47 µF tantalum capacitor must be placed as close as possible of the MS5561's VDD pin. This capacitor will stabilize the power supply during data conversion and thus, provide the highest possible accuracy.
DA5561_03 January 5, 2009 14
000055611126 – ECN1158
www.sensorway.cn
Page 15
APPLICATION EXAMPLE: ALTIMETER SYSTEM USING MS5561
MS5561 can be used in connection with a microcontroller in mobile altimeter applications. It is designed for low­voltage systems with a supply voltage of 3 V, particularly in battery applications. The MS5561 is optimized for low current consumption as the AD-converter clock (MCLK) can use the 32.768 kHz frequency of a standard watch crystal, which is supplied in most portable watch systems.
For applications in altimeter systems Intersema can deliver a simple formula to calculate the altitude, based on a linear interpolation, where the number of interpolation points influences the accuracy of the formula.
3V-Battery
MS5561
VDD
MCLK
DIN DOUT SCLK
GND
32.768 kHz
47uF Tantal
XTAL1
XTAL2
GND
LCD-Display
VDD
Microcontroller
EEPROM
optional
Figure 7: Demonstration of MS5561 in a mobile altimeter.
RECOMMENDED PAD LAYOUT
Pad layout for bottom side of MS5561 soldered onto printed circuit board.
Keypad
DA5561_03 January 5, 2009 15
000055611126 – ECN1158
www.sensorway.cn
Page 16
DEVICE PACKAGE OUTLINES
Fig. 8: Device package outlines of MS5561.
DA5561_03 January 5, 2009 16
000055611126 – ECN1158
www.sensorway.cn
Page 17
ASSEMBLY
MOUNTING
The MS5561 can be placed with automatic Pick&Place equipment using vacuum nozzles. It will not be damaged by the vacuum. Due to the low stress assembly the sensor does not show pressure hysteresis effects. It is important to solder all contact pads to avoid floating of the sensor during soldering. The pins PEN and PV shall be left open or connected to VDD. Do not connect the pins PEN and PV to GND!
CLEANING
The MS5561 has been manufactured under cleanroom conditions. Each device has been inspected for the homogeneity and the cleanness of the silicone gel. It is therefore recommended to assemble the sensor under class 10’000 or better conditions. Should this not be possible, it is recommended to protect the sensor opening during assembly from entering particles and dust. To avoid cleaning of the PCB, solder paste of type “no-clean” shall be used. Cleaning might damage the sensor!
ESD PRECAUTIONS
The electrical contacts except programming pads are protected against ESD up to 4 kV HBM (human body model). The MS5561 is shipped in antistatic transport boxes. Any test adapters or production transport boxes used during the assembly of the sensor shall be of an equivalent antistatic material.
DA5561_03 January 5, 2009 17
000055611126 – ECN1158
www.sensorway.cn
Page 18
SHIPPING PACKAGE
TAPE
Units per reel 4’000 Minimum empty leader
(right side of drawing) Tape widths 12 mm Tape material Black Conductive Polystyrene Reel diameter 13” / 330 mm
Minimum empty trailer
(left side of drawing,
direction of unreeling)
250 mm
250 mm
Fig. 9: Outline of tape for MS5561.
Fig. 10: Outline of reel for MS5561.
DA5561_03 January 5, 2009 18
000055611126 – ECN1158
www.sensorway.cn
Page 19
ORDERING INFORMATION
Product Code
Product Art.-Nr. Package Comments
MS5561-C Micro Altimeter 325561000 Small Size SMD with metal lid
Module height
1.6 mm
FACTORY CONTACTS
Intersema Sensoric SA Ch. Chapons-des-Prés 11 CH-2022 Bevaix
Switzerland
Tel. 032 847 9550 Tel. Int. +41 32 847 9550 Telefax +41 32 847 9569 e-mail:
http://www.intersema.ch
NOTICE
THIS ADVANCE INFORMATION IS STILL UNDERGOING CONTINOUS CHANGES.
Intersema reserves the right to make changes to the products contained in this data sheet. Intersema assumes no responsibility for the use of any circuits shown in this data sheet, conveys no license under any patent or other rights unless otherwise specified in this data sheet, and makes no claim that the circuits are free from patent infringement. Applications for any devices shown in this data sheet are for illustration only and Intersema makes no claim or warranty that such applications will be suitable for the use specified without further testing or modification.
中国
北京赛斯维测控技术有限公司 北京市朝阳区望京西路48号 金隅国际C座1002 电话:+86 010 8477 5646 传真:+86 010 5894 9029
jiangarmy@126.com
邮箱:
DA5561_03 January 5, 2009 19
000055611126 – ECN1158
www.sensorway.cn