1
AC INPUT, SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
MPU150-S259 12V 11.6V to 16V 15A (Note 3) 0.1% 1% 1% 11.97V to 12.03V
MPU150-S262 24V 22.8V to 29.2V 7.5A (Note 3) 0.1% 1% 1% 23.95V to 24.05V
MPU150-S261 48V 45V to 56V 3.75A (Note 3) 0.1% 1% 1% 47.9V to 48.1V
AC INPUT, MULTIPLE OUTPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY
+3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V
MPU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V
+12V Fixed 2A 0.4% 3% 1% 11.76V to 12.24V
+5V 5.0V to 5.5V 17.5A 0.4% 1% 1% 4.98V to 5.02V
MPU150-3524 +12V 10.8V to 13.2V 4A 0.4% 3% 1% 11.94V to 12.06V
+24V Fixed 2A 0.4% 3% 1% 23.52V to 24.48V
+5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4000
+12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V
+2.5V 2.25V to 3.0V 30A (Note 4) 0.8% 2% 2% 2.49V to 2.51V
MPU150-4230
+3.3V 3.15V to 3.8V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 4A (Note 5) 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A (Note 5) 0.4% 1% 1% 4.98V to 5.0V
+3.3V 3.15V to 3.80V 30A (Note 4) 0.6% 1.5% 1% 3.28V to 3.32V
MPU150-4350
+5V 5.0V to 5.5V 15A (Note 4) 0.4% 1% 1% 5.00V to 5.04V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
+5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4530
+3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V1 and V2 is 30A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V3 and V4 is 5A, maximum rating.
3) Total power of 180 Watts.
The innovative MPU products incorporate Power Factor Correction (PFC) with a
low profile package designed to meet 1U height constraints. The MPU150-4530
and MPU150-4350 provide high current +3.3V and +5V on a single platform to
support mixed mode, high speed digital circuitry. Power-One’s unique dual
converter architecture combines high reliability with exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide
independent compensation of output cable losses. Other standard features include
independent current sharing on V1 and V2, thermal shutdown, and remote inhibit.
Airflow of 300 linear feet per minute (LFM) is required to deliver the full power
density of 3.0 watts per cubic inch.
The MDU150 series provides the same benefits as the MPU150 series, with
nominal 48 volt DC input.
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Low Profile Height Fits 1U Constraints
• Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications
• Single Wire Current Sense on Outputs V1 and V2
• Remote Sense on Outputs V1 and V2
• Overtemperature, Overload, and Overvoltage Protection
• Available with Metric or SAE Mountings
• Greater than 340,000 Hours MTBF
• MDU150 Models have 48VDC Input
MPU150/MDU150 SERIESMPU150/MDU150 SERIES
REV. 09/01