Datasheet MPU150-S259, MPU150-S261, MPU150-S262, MPU150-3524, MPU150-4230 Datasheet (POWER-ONE)

Page 1
1
AC INPUT, SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
MPU150-S259 12V 11.6V to 16V 15A (Note 3) 0.1% 1% 1% 11.97V to 12.03V MPU150-S262 24V 22.8V to 29.2V 7.5A (Note 3) 0.1% 1% 1% 23.95V to 24.05V MPU150-S261 48V 45V to 56V 3.75A (Note 3) 0.1% 1% 1% 47.9V to 48.1V
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY
+3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V
MPU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V
+12V Fixed 2A 0.4% 3% 1% 11.76V to 12.24V
+5V 5.0V to 5.5V 17.5A 0.4% 1% 1% 4.98V to 5.02V
MPU150-3524 +12V 10.8V to 13.2V 4A 0.4% 3% 1% 11.94V to 12.06V
+24V Fixed 2A 0.4% 3% 1% 23.52V to 24.48V
+5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4000
+12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V
+2.5V 2.25V to 3.0V 30A (Note 4) 0.8% 2% 2% 2.49V to 2.51V
MPU150-4230
+3.3V 3.15V to 3.8V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 4A (Note 5) 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A (Note 5) 0.4% 1% 1% 4.98V to 5.0V
+3.3V 3.15V to 3.80V 30A (Note 4) 0.6% 1.5% 1% 3.28V to 3.32V
MPU150-4350
+5V 5.0V to 5.5V 15A (Note 4) 0.4% 1% 1% 5.00V to 5.04V 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4530
+3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V1 and V2 is 30A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V3 and V4 is 5A, maximum rating.
3) Total power of 180 Watts.
The innovative MPU products incorporate Power Factor Correction (PFC) with a low profile package designed to meet 1U height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform to support mixed mode, high speed digital circuitry. Power-One’s unique dual converter architecture combines high reliability with exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch.
The MDU150 series provides the same benefits as the MPU150 series, with nominal 48 volt DC input.
FEATURES
Power Factor Correction (PFC) Meets EN61000-3-2
Low Profile Height Fits 1U Constraints
Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications
Single Wire Current Sense on Outputs V1 and V2
Remote Sense on Outputs V1 and V2
Overtemperature, Overload, and Overvoltage Protection
Available with Metric or SAE Mountings
Greater than 340,000 Hours MTBF
MDU150 Models have 48VDC Input
MPU150/MDU150 SERIESMPU150/MDU150 SERIES
REV. 09/01
Page 2
2
DC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY
+3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V
MDU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V
+12V N/A 2A 0.4% 3% 1% 11.76V to 12.24V
+5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V
MDU150-4000
+12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V
+5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V
MDU150-4530
+3.3V 3.15V to 3.60V 15A (Note 3) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V
MPU150 INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 150 watts. MPU150-4350 17.5 mS
All other models 20 Input Current 85 VAC at full rated load. MPU150 3.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. 100 120
Switching frequency of secondary transformer. 65 90 kHz Switching frequency of Power Factor Correction circuit. 60
MDU150 INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - DC Continuous input range. 36 75 VDC Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 150 watts, over DC input range. 20 mS Input Current 36 VDC at full rated load. 6.4 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Vin = 72 VDC. 35 APK Operating Frequency Switching frequency of main output transformer. 100
kHz
Switching frequency of secondary transformer. 70
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 3) Total current between V1 and V2 is 30A, maximum rating.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 4) Total current between V3 and V4 is 5A, maximum rating.
MPU150/MDU150 SERIESMPU150/MDU150 SERIES
Page 3
3
MPU150/MDU150 SERIES
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 65 75 % Minimum Load, V1 Minimum load required to maintain regulation on MPU150-3300, V1 4
A
V2 at maximum load. All other models, V1 3
Minimum Load, V3 Minimum load required to maintain regulation on MPU150-3300, V3 N/A
A
V4 at maximum load. All other models, V3 0.3 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Charts Output Power With 300 LFM forced air cooling. (Note 1) 150 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified.
See Model Selection Charts
input range, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change,
500 µS
5% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection Latch style overvoltage protection. Available on 2.5V output, V1 3.0 3.25
V1, V2, all models, and V3 on all models except 3.3V output, V1 4.1 4.65
MPU150-3300. 3.3V output, V2 3.8 4.2
5V output, V1, V2 6.0 6.4 V
12V output, V2 (Note 2) 14 16
MPU150-4350 3.3V output, V1 4.3 4.65 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good TTL compatible signal available for V1. Signal is high when 3.3V 3.16
output is within 5% of nominal. Signal shall remain low for 20 5V 4.75 V milliseconds following loss of Output Good.
Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input
5mS
power. May be used as independent PSOK signal in redundant applications.
Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share 10 %
on V1 and V2 with return via -Sense return.
Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with
500 mV
respect to the main output.
Inhibit Output voltage is inhibited by application of an external high (5V) signal.
NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL1950.
CSA 22.2 NO. 234/950. Approved EN60950 (TÜV).
Dielectric Withstand Voltage Input to output per EN60950. MPU150 2600
VDC
MDU150 1544
Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. B
Class
EN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Transient Protection Per EN61000-4-5, class 3. Line to Line 1
kV
Line to Ground 2 Insulation Resistance Input to output. 10 M Leakage Current Per EN60950. MPU150 at 264 VAC 1250
µA
MDU150 at 72 VDC 100
NOTES: 1) This product is not rated for convection applications. 2) Overvoltage range for 12V, V3 outputs: 14V to 19V.
Page 4
4
MPU150/MDU150 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating. 10k ASL Ft.
Non-Operating. 40k ASL Ft.
Operating Temperature At 100% load 0 50 °C
Derate linearly above 50°C by 2.5% per °C. At 50% load 0 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 G
PK
Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 G
RMS
OPTIONS
DESCRIPTION NOTES SIZE IMPACT
Metric Mounting Add “M” as a suffix to the model number to order chassis with 8.00" x 4.20" x 1.50"
M4 x 0.7 mounting inserts. (203.2mm x 106.7mm x 38.1mm)
Page 5
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
5
MPU150/MDU150 SERIES
OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg)
M4 X 0.7, 8 PLACES. MAXIMUM TORQUE: 3.5 IN/LBS (0.40 N/M)
CONNECTOR
MOLEX
HOUSING
PIN PINS PINS WIRE
SERIES SERIES (LOOSE) (CHAIN) GAUGE
41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG
J1
41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG
(ALL MODELS)
2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG
J300 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG
INPUT
SINGLE OUTPUT
J1
L N
V1,V. ADJ.
OUTPUTS:
8-32 SCREW CONNECTIONS (4PL)
+V1
RTN
INTERFACE CONNECTIONS (J300)
S
PIN
10. +S, V1
9. -S, V1
8. CURRENT SHARE, V1
7. NO CONNECTION
6. NO CONNECTION
5. NO CONNECTION
4. OUTPUT GOOD, V1
3. POWER FAIL WARNING
2. INHIBIT
1. SIGNAL GROUND
ON 2.50mm CENTERS. MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&) PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS
Page 6
CONNECTOR
MOLEX
HOUSING
PIN PINS PINS WIRE
SERIES SERIES (LOOSE) (CHAIN) GAUGE
41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG
J1
41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG
(ALL MODELS)
2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG
J2 5051-N 22-01-1022 2759 08-50-0114 08-50-0113 22-30AWG
(TRIPLE OUTPUT) 5051-N 22-01-1022 2759 08-65-0805 08-65-0804 22-30AWG
41695 09-50-8021 6838 08-50-0189 08-50-0187 18-20AWG
J3
41695 09-50-8021 2478 08-50-0106 08-50-0105 18-20AWG
(TRIPLE OUTPUT)
2139 09-50-3021 2478 08-50-0106 08-50-0105 18-20AWG
41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20AWG
J3
41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20AWG
(QUAD OUTPUT)
2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20AWG
J300 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG
6
MPU150/MDU150 SERIES
OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg)
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
Loading...