Datasheet MDU13H-5MC3, MDU13H-5C3, MDU13H-50, MDU13H-50C3, MDU13H-50M Datasheet (Datadelay)

...
Page 1
MDU13H
TRIPLE, ECL-INTERFACED
data
3
1
16
GND
VEE
GND
FIXED DELAY LINE (SERIES MDU13H)
delay devices, inc.
FEATURES PACKAGES
GND
1
Fits standard 16-pin DIP socket
Auto-insertable
I1
VEE
5
I2
6
I3
7 8
Input & outputs fully 10KH-ECL interfaced & buffered
MDU13H-xx DIP MDU13H-xxM Military DIP
FUNCTIONAL DESCRIPTION
The MDU13H-series device is a 3-in-1 digitally buffered delay line. The signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
GND
16
O1
15
O2
14
O3
13
N/C N/C N/C
MDU13H-xxC3 SMD MDU13H-xxMC3 Mil SMD
PIN DESCRIPTIONS
I1-I3 Signal Inputs O1-O3 Signal Outputs VEE -5 Volts GND Ground
2
15 3 4 5
I1
6
I2
7
I3
8
O1
14
O2
13
O3
12
N/C
11
N/C
10
N/C
9
N/C
SERIES SPECIFICATIONS
Minimum input pulse width: 50% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
O3O2O1
100%
100% 100%
VCC GNDI1 I2 I3
Functional block diagram
DASH NUMBER SPECIFICATIONS
Part
Number
MDU13H-3 MDU13H-4 MDU13H-5 MDU13H-10 MDU13H-15 MDU13H-20 MDU13H-25 MDU13H-30 MDU13H-35 MDU13H-40 MDU13H-45 MDU13H-50
* Total delay is referenced to first tap output Input to first tap = 1.5ns ±± 1ns
NOTE: Any dash number between 3 and 50
not shown is also available.
Delay Per
Line (ns)
3 ± 1.0 4 ± 1.0
5 ± 1.0 10 ± 1.0 15 ± 1.0 20 ± 1.0 25 ± 2.0 30 ± 2.0 35 ± 2.0 40 ± 2.0 45 ± 2.2 50 ± 2.5
1997 Data Delay Devices
Doc #97037 DATA DELAY DEVICES, INC. 1
12/11/97 3 Mt. Prospect Ave. Clifton, NJ 07013
Page 2
MDU13H
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU13H tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 50% of the total delay and periods as small as 100% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage V Input Pin Voltage V Storage Temperature T Lead Temperature T
EE
IN STRG LEAD
Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU13H relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used.
-7.0 0.3 V
VEE - 0.3 0.3 V
-55 150 C 300 C 10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage V Low Level Output Voltage V High Level Input Voltage V Low Level Input Voltage V High Level Input Current I Low Level Input Current I
OH OL
IH
IL IH IL
(0C to 75C)
-1.020 -0.735 V
-1.950 -1.600 V
-1.070 V
-1.480 V 475
0.5
µA µA
VIH = MAX,50 to -2V VIL = MIN, 50 to -2V
VIH = MAX VIL = MIN
Doc #97037 DATA DELAY DEVICES, INC. 2
12/11/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
Page 3
MDU13H
PACKAGE DIMENSIONS
.800 TYP.
.018 TYP.
.700 TYP.
.880±.020
.020 TYP.
.100
.090
.700
.010±.002
16 15 14 13
.400 TYP.
1 5 6 7 8
.320
.020
MAX.
TYP.
.150
±.030
.100 TYP.
MDU13H-xx (Commercial DIP) MDU13H-xxM (Military DIP)
.010 TYP.
.300 TYP.
.040 TYP.
910111213141516
.882
±.005
.007
±.005
.050
±.010
1 2 3 4 5 6 7 8
.710
±.005
.590
MAX.
.280 MAX.
MDU13H-xxC3 (Commercial SMD) MDU13H-xxMC3 (Military SMD)
Doc #97037 DATA DELAY DEVICES, INC. 3
12/11/97 3 Mt. Prospect Ave. Clifton, NJ 07013
Page 4
MDU13H
DELAY LINE AUTOMATED TESTING
O1
TRIGINREF
OSCILLOSCOPE
O2O3OUT
TRIGI1I2
I3
20%
20%
50%
50%
80%
80%
50%
50%
TEST CONDITIONS
INPUT: OUTPUT: Ambient Temperature: 25oC ± 3oC Load: 50 to -2V Supply Voltage (Vcc): -5.0V ± 0.1V C Input Pulse: Standard 10KH ECL Threshold: (VOH + VOL) / 2
levels (Rising & Falling)
Source Impedance: 50 Max. Rise/Fall Time: 2.0 ns Max. (measured
between 20% and 80%)
Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
: 5pf ± 10%
load
PULSE
GENERATOR
INPUT SIGNAL
T
RISE
T
RISE
PW
V
DEVICE UNDER
IN
IH
TEST (DUT)
Test Setup
PER
IN
T
FALL
T
FALL
V
IL
Doc #97037 DATA DELAY DEVICES, INC. 4
12/11/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
OUTPUT SIGNAL
V
OH
Timing Diagram For Testing
V
OL
Loading...