1
MAP140 SERIES
Power-One’s MAP140 series provides a full range of options and up
to 30 watts more power than comparable products in this industry
standard footprint. With a universal input from 85 to 264 VAC and
power densities up to 2.6 watts/inch
3
, the MAP140 meets the most
rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced air cooled (200 LFM)
applications, the MAP140 delivers dependable power with a Mean
Time Before Failure (MTBF) in excess of 180,000 hours. In addition
to UL, CSA, and TÜV regulatory compliance, the MAP140 displays
the CE Mark.
FEATURES
• Universal Input 85-264 VAC
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4
• CE Marked to Low Voltage Directive
• Industry Standard Footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
• Remote Sense and Overvoltage Protection
• Power Fail Signal Standard on MAP140-3000P, Optional
on MAP140-1012 and MAP140-1024
• Optional Overtemperature Protection, L-Bracket, and Cover.
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT ADJUSTMENT CONVECTION FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE COOLED CURRENT CURRENT (NOTE 3) REGULATION REGULATION %p-p (NOTE 1) ACCURACY
MAP140-1012 12V/15V 11.0V to 16.0V 9.2/7.3A (Note 2) 12.5A/10A (Note 2) 0.1% 0.5% 1% 11.97V to 12.03V
MAP140-1024 24V/28V 22.8V to 29.2V 4.6/4A (Note 2) 6.3A/5.4A (Note 2) 0.1% 0.5% 1% 23.95V to 24.05V
MAP140-1048 48V 45.6V to 54.0V 2.3A 3.1A 0.1% 0.5% 1% 47.9V to 48.1V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 140W FORCED AIR COOLED (200 LFM)
MODEL
OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.75 - 5.25V 16A/25A 20A/25A PK 0.2% 1% 1% 5.09V to 5.11V
MAP140-3000P +12V Fixed 4A/9A PK 4A/9A PK 0.1% 2% 1% 11.97V to 12.03V
-12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 2% 1% -11.4V to -12.6V
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC
Hold-up Time Nominal AC input voltage (110 VAC) 110 watt load: 20
mS
140 watt load: 16
Input Current 85 VAC (140W load). 2.5
ARMS
110 VAC (140W load). 2.0
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25°C. 41 APK
Operating Frequency Switching frequency of main transformer. 22 kHz
Rev. 04/2000
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.