1
Power-One’s MAP130 series of single and multiple output power
supplies provide fully regulated outputs with high-peak current
capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis.
Other standard features include autoselect AC input, EMI level B
filtering, power fail, thermal shutdown (with warning), remote sense,
and metric and SAE mounting inserts.
This convection-cooled series is designed for use in commercial and
industrial environments in temperatures up to 50 degrees C. All
products are approved to the latest international regulatory standards,
and display the CE Mark.
FEATURES
• Automatic 115/230 Input Voltage Selection
• All Outputs Fully Regulated
• Remote Sense, Overvoltage Protection, and Overtemperature Protection
• Power Fail Signal Included
• Greater than 100,000 Hour MTBF
• U-Channel Chassis: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm)
• Optional Cover
• Metric and SAE Mounting Inserts
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT ADJUSTMENT CONTINUOUS PEAK LINE LOAD TYPICAL RIPPLE & INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION NOISE %p-p (NOTE 1) ACCURACY
MAP130-1005 5V 4.75V to 5.50V 26A 30A 0.2% 1% 1% 5.1V to 5.2V
MAP130-1012 12V/15V 11.4V to 15.75V 12A/10A (Note 2) 13.8A/11A 0.2% 1% 1% 12.0V to 12.2V
MAP130-1024 24V/28V 22.5V to 30.0V 6.2A/5.4A (Note 2) 6.8A/5.9A 0.2% 1% 1% 23.9V to 24.1V
NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
MULTIPLE OUTPUT MODEL SELECTION CHART – 130W CONTINUOUS OUTPUT POWER
MODEL
OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
MAP130-4000
+12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.75V to 12.0V
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
MAP130-4001
+24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
MAP130-4002
+12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.9V to 12.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V
MAP130 SERIES
Rev. 04/2000
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.