Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
MODEL NO.:M190E5-C03
Customer :
pproved by :
Note :
www.jxlcd.com
www.jxlcd.com
記錄 工作 審核 角色 投票
2006-12-13 08:59:43 CST
2006-12-11 18:53:35 CST
Approve by Dept. Mgr.(QA RA)
Approve by Director
tomy_chen(陳永一 /52720/54140/43150)
teren_lin(林添仁 /56910/36064)
Department Manager(QA RA)
Director Accept
Accept
/15
1
Version 2.1
Page 2
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
- CONTENTS -
.
REVISION HISTORY ------------------------------------------------------- 3
1. GENERAL DESCRIPTION ------------------------------------------------------- 4
1.1 OVERVIEW
1.2 FEATURES
1.3 APPLICATION
1.4 GENERAL SPECIFICATIONS
2. ABSOLUTE MAXIMUM RATINGS ---------------------------------------------- 4
3. SUGGESTIVE DRIVING CONDITION ---------------------------------------------- 5
4. PANEL PIN DEFINITION ------------------------------------------------------- 6
5. OPTICAL CHARACTERISTICS ---------------------------------------------- 7
5.1 TEST CONDITIONS
5.2 OPTICAL SPECIFICATIONS
6. PACKAGING --------------------------------------------- 11
6.1 PACKING SPECIFICATIONS
6.2 PACKING METHOD
7. DEFINITION OF LABELS ---------------------------------------------- 13
8. PRECAUTIONS ---------------------------------------------- 14
8.1 ASSEMBLY AND HANDLING PRECAUTIONS
8.2 SAFETY PRECAUTIONS
9. PANEL DRAWING ---------------------------------------------- 15
www.jxlcd.com
www.jxlcd.com
/15
2
Version 2.1
Page 3
REVISION HISTORY
Version Date Section Description
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
Ver 2.0
Ver 2.1
Oct,23 ’06
Dec.11 ‘06
-
M190E5-C03 Approval Specifications was first issued
9
Modify cell drawing
www.jxlcd.com
www.jxlcd.com
/15
3
Version 2.1
Page 4
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
1.GENERAL DESCRIPTION
1.1 OVERVIEW
The M190E5-C03 is a 19-inch LCD cell with thin film transistors as active elements and contains
1280x1024 pixels. Each pixel is divided into red, green and blue dot, which are arranged in vertical stripe.
The cell is normally white mode, and can be applied to the transmission type display. Backlight unit (BLU)
and circuit board for the cell are not built in.
1.2 FEATURES
- Wide viewing angle
- High contrast ratio
- Fast response time
- SXGA (1280 x 1024 pixels) resolution
1.3 APPLICATION
- LCD Monitor
- LCD TV
1.4 GENERAL SPECIFICATIONS
Item Specification Unit Max Panel Dimension (TFT) 387.52 X 312.056 mm Glass thickness( TFT/ CF ) 0.7/ 0.7 mm Active Area 376.32 (H) x 301.056 (V) (19.0” diagonal) mm Driver Element a-si TFT active matrix ­Pixel Number 1280X R.G.B X 1024 pixel Pixel Pitch 0.294 (H) X 0.294 (V) mm Pixel Arrangement RGB vertical stripe ­Transmissive Mode Normally white ­Surface Treatment Hardness (3H), AG (Haze 25%) ­Polarizer Type E-Wide View -
Polarizer Dimension
Polarizer Thickness
2. ABSOLUTE MAXIMUM RATINGS
1. Storage condition : With shipping package.
www.jxlcd.com
www.jxlcd.com
TFT 380.52 X 304.13 mm
CF 383.15 X 307.85 mm
TFT 0.21 mm
CF 0.21 mm
Weight 470(typ.) g
2. Storage temperature range : 25±5 ℃.
3. Storage humidity range : 50±10% RH.
4. Shelf life : 30 days
Version 2.1
/15
4
Page 5
3. Suggestive Driving Condition
Item Min. Typ. Max. Unit
VG
Driving Voltage
B: Black pattern
W: White pattern
VD
V
G-D offset
Charging time - 9.8 - us
On 23.7 24.5 25.3 V Off -7.0 -6.8 -6.6 V
Gam1 -
B
Gam14 -
Gam7 -
W
Gam8 -
Center 4.81 5.31 5.81 V
COM
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
12.105
0.128
6.688
6.283
2.0 - - us
- V
- V
- V
- V
Gamma Voltage : Gam1 > Gam2 > Gam3 > … > Gam10
G: gate pulse falling edge
DRIVING TIMING DIAGRAM
www.jxlcd.com
www.jxlcd.com
VCOM
VD
VG
/15
5
Version 2.1
Page 6
4. PANEL PIN DEFINITION
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
Pin No.
TAB1 TAB2 ~ 9 TAB10
1~2 Test pin* Test pin* Test pin*
3 Test pin* NC NC
4 NC NC NC 5 NC NC NC 6 XAO NC NC 7 OE NC NC 8 CPV NC NC
9 STV NC NC 10~12 Vss NC NC 13~15 Vdd NC NC 16~17 Vee NC NC
18 NC NC NC
19~24 Vgl NC NC
25 NC NC NC
26~31 Vgh NC NC
32 NC NC NC
33~34 Vcom NC NC
35 Vcom Vcom Vcom
www.jxlcd.com
36 Test pin* Test pin* Test pin* 37 Out1 Out1 Out1
38 ~ 419 out2 ~out 383 out2 ~out 383 out2 ~out 383
420 out384 out384 out384 421 Test pin* Test pin* Test pin* 422 NC NC Test pin*
423 NC NC NC 424~425 NC NC GND 426~427 NC NC Vgl
428 NC NC NC 429~430 NC NC Vcom
431 NC NC Test pin*
432 NC NC NC 433~434 Vcom Vcom Vcom 435~436 Test pin* Test pin* Test pin*
Note: Recommended Gate IC for the cell is HiMAX’s HX8633APD400, 256Ch, or equivalent.
www.jxlcd.com
Data driver Pin Define
/15
6
Version 2.1
Page 7
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
5. OPTICAL CHARACTERISTICS
5.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta Ambient Humidity Ha Gamma voltage - Refer to Item 3 driving condition V
Vcom - most suitable Vcom V
25±2
50±10
5.2 OPTICAL SPECIFICATION
ITEM Symbol Condition MIN. TYP. MAX. UNIT NOTE
Contrast Ratio CR θx=θy=0° 450 800 - % 4,1
Response Time
(Black/White)
Center point Transmittance T% θx=θy=0° 5.1 5.7 - % 7,1
Tr θx=θy=0° ­Tf θx=θy=0° -
1.3 6
3.7 8
Doc No.: 1406Y149
Approval
o
C
%RH
ms ms
5,1
Transmittance uniformity
(9pts)
Horizontal θx
Viewing
Angle
Color
Coordinate
at center
point
(θy=0°)
Vertical θy
(θx=0°)
Red
Green
Blue
www.jxlcd.com
www.jxlcd.com
White
δT%
Right
Left 70
Up 70
Down
Rcx θx=θy=0° 0.646 ­Rcy θx=θy=0° 0.326 ­Gcx θx=θy=0° 0.276 ­Gcy θx=θy=0° 0.592 ­Bcx θx=θy=0° 0.148 -
Bcy θx=θy=0° 0.105 ­Wcx θx=θy=0° 0.314 ­Wcy θx=θy=0°
θx=θy=0° - 1.25 1.4 - 6,1
CR10
Note (0)
Light source is the standard light source “C” which is defined by CIE and driving voltages are based on
suitable gamma voltages. The calculating method is as following
1.Measure Module’s and BLU’s spectrums. White is without signal input and R, G, B are with signal input.
BLU is supplied by CMO.
2.Calculate cell’s spectrum.
70 80
80 80
70
Typ.
-0.03
80
0.350
- Deg
- Deg
- Deg
- Deg
Typ.
+0.03
-
2,3,1
2,0
3.Calculate cell’s chromaticity by using the spectrum of standard light source “C”
/15
7
Version 2.1
Page 8
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
Note (1)
Light source is the BLU which is supplied by CMO and driving voltages are based on suitable gamma
voltages. White is without signal input and R, G, B are with signal input. SPEC is judged by CMO’s golden sample .
Note (2) : Measurement setup:
The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt temperature
change during measuring. In order to stabilize the luminance, the measurement should be executed after lighting
backlight for 20 minutes in a windless room.
LCD Module
LCD Panel
USB2000
Center of the Screen
500 mm
www.jxlcd.com
www.jxlcd.com
CS-1000T
Light Shield Room (Ambient Luminance < 2 lux)
/15
8
Version 2.1
Page 9
Note (3) : Definition of viewing angle (θx ,θy):
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
Note (4) : Definition of Contrast Ratio (CR):
Ratio of gray max (Gmax), gray min (Gmin), at the center point of panel.
www.jxlcd.com
CR =
Note (5) : Definition of Response Time (T
Response
www.jxlcd.com
100%
90%
Optical
10%
Luminance with all pixel white (Gmax)
Luminance with all pixel Black (Gmin)
Gray Level 255
R, TF):
Gray Level 255
Gray Level 0
Version 2.1
0%
T
R
/15
9
FT
Time
Page 10
Note (6) : Definition of Transmittance Variation (δT%):
Measure the transmittance at 9 points
δT% =
Maximum [T%(1), T%(2), … T%(9)]
Minimum [T%(1), T%(2), … T%(9)]
D/10
Horizontal Line
D
D/2
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
9D/10
W
W/10
W/2
1
4
Vertical Line
www.jxlcd.com
Note (7) : Definition of Transmittance(T%):
Module is without signal input.
BLU is Supplied by CMO .
www.jxlcd.com
Transmittance
9W/10
=
7 8 9
Luminance of LCD module
Luminance of backlight
2
5
Active Area
100%
3
X
6
: Test Point
X=1 to 9
/15
10
Version 2.1
Page 11
6. PACKAGING
6.1 PACKING METHOD
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
www.jxlcd.com
www.jxlcd.com
Figure. 6-1 Packing method
/15
11
Version 2.1
Page 12
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
www.jxlcd.com
www.jxlcd.com
Figure. 6-2 Packing method
/15
12
Version 2.1
Page 13
7. DEFINITION OF LABEL
1. Mode Name: M190E5- C03
2. Panel Type: version control
3. Quantity: 20pcs / box
4. Case ID: serial number.
5. Note: Notification, if necessary.
6. Barcode: Case ID in code39 format
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
Figure. 7-1 Carton Label
www.jxlcd.com
www.jxlcd.com
/15
13
Version 2.1
Page 14
Doc No.: 1406Y149
Issued Date: Dec.11, 2006
Model No.: M190E5-C03
Approval
8. PRECAUTIONS
8.1 ASSEMBLY AND HANDLING PRECAUTIONS
1. Do not apply rough force such as bending or twisting to the cell during assembly.
2. To assemble or install cell into customer’s module can be only in clean working areas. The dust and
oil may cause electrical short or worsen the polarizer.
3. It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight
will be damaged.
4. Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
5. It is dangerous that moisture come into or contacted the LCD panel, because moisture may damage
TFT circuit .
6. High temperature or humidity may reduce the performance of cell. Please store LCD cell within the
specified storage conditions.
8.2 SAFETY PRECAUTIONS