Datasheet LWR-1601-6, LWN1701-6, LWN1240-6M1, LWN-1801-6, LWN-1601-6 Datasheet (POWER-ONE)

...
Page 1
1
www.power-one.com
Edition 5/07.2001
• Electrically and mechanically rugged DIN-rail front end
• Outputs individually controlled with 150% output peak power
Input range 85...264 V AC with PFC 1 or 2 isolated, regulated outputs up to 96 V 3 kV AC I/O electric strength test voltage
Selection chart for front ends
Output 1 Output 2 Input voltage Rated power Type Options
1
U
o nomIo nom
U
o nomIo nom
U
i min Ui max
T
A
= 60°C
[V DC] [A] [V DC ] [A]
P
o tot
[W]
24.7 5 - - 125 LWR-1601-6 R
24.7 10 - - 250 LWN-1601-6 D1D5 37 3.3 - - 85...264 VAC 125 LWR 1701-6 S
37 6.6 - -
(14440 Hz)
3
250 LWN 1701-6 M2
49.4 2.6 - - 90350 VDC 125 LWR 1801-6 F, F1
49.4 5 - - 250 LWN-1801-6 K2
24.7 5 24.7 5 250 LWN-2660-6
49.4 2.5 49.4 2.5 250 LWN 2880-6
W Series 125 and 250 Watt AC-DC Converters
LGA
Selection chart for battery chargers
Output Input voltage Rated power Type Options
1
U
o nom
I
o nom
U
i min Ui max
T
A
= 60°C
[V DC] [A]
P
o tot
[W]
25.7...29.3 4.2 85264 VAC 115 LWR 1240-6 M1 F, F1
25.7...29.3 8.45
(14440 Hz)
3
230 LWN 1240-6 M1 K2
51.4...58.6 2.1 90350 VDC 115 LWR 1740-6 M1
51.4...58.6 4.2 230 LWN 1740-6 M1
1
For lead times and minimum order quantity contact Power-One.
2
For availability contact Power-One.
3
Input frequency range certified for 14...440 Hz. For continuous operating frequency <40 Hz and >100 Hz contact
factory.
Page 2
2
www.power-one.com
Edition 5/07.2001
Input
Input voltage world wide mains, single phase 85...264 V AC
derating information see application note 90...350 V DC Input frequency 14...440 Hz Power factor active PFC up to 0.99 Inrush current virtually no inrush current
Output
Efficiency
U
i nom
,
I
o nom
up to 89 %
Output voltage setting accuracy
U
i nom
,
I
o nom
± 1.3%
U
o nom
Output voltage noise IEC/EN 61204 typ. 50 mV Output voltage ripple sinusoidal output ripple at wice the line frequency 1.2 V
pp
Line and cross regulation
U
i min
...
U
i max
typ. 50 mV
Load regulation 0...100%
I
o nom
,
U
i nom
–1.6%
U
o nom
Minimum load not required Current limitation rectangular U/I characteristic 101...112%
I
o nom
Short term peak power 1 s, electronically controlled 150 %
I
o nom
Operation in parallel enabled by droop current share Hold-up time
I
o nom
,
U
o
decreases to 80% of
U
o nom
typ. 15 ms
Control
Status indication LED output(s) OK
Protection
Input fuse not user accessible6.3 A, slow blow Input reverse polarity bridge rectifier Input undervoltage lockout typ. 80%
U
i min
Input overvoltage lockout typ. 105 %
U
i max
Input transient protection voltage depending resistor (VDR) Output(s) no-load, overload and short circuit proof Output overvoltage second control loop, each output, 24 V/48 V 30/60 V SELV Overtemperature reduced output power if thermally overloaded
Safety
Approvals EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed Electric strength test voltage class I, I/case 2 kV AC
class I, I/O 3 kV AC
class I, O/case 1 kV AC
class I, O/O 0.35 kV AC Pollution degree AC-in / DC-in 3/2 Degree of protection IP 20
W Series 125 and 250 Watt AC-DC Converters
Page 3
3
www.power-one.com
Edition 5/07.2001
DIN Rail Mountable W Series
EMC
Electrostatic discharge IEC/EN 61000-4-2, level 4, contact/air (8/15 kV) criterion A Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A Electr. fast transients/bursts IEC/EN 61000-4-4, level 4, capacitive/direct (4/2 kV) criterion A Surge IEC/EN 61000-4-5, level 3, in and out, line to line (2 kV) criterion B
level >3, input, line to case (3.5 kV) criterion B
level 2, output, line to case (1 kV) criterion A Conducted disturbances IEC/EN 61000-4-6, level 3 (10 V) criterion A Electromagnetic emissions CISPR 22/EN 55022, conducted class A
Environmental
Operating ambient temperature
U
i nom
,
I
o nom
, convection cooled –40...60°C
Operating case temperature
TCU
i nom
,
I
o nom
–40...87°C Storage temperature non operational –40...100°C Damp heat IEC/EN 60068-2-3, 93%, 40°C 56 days Shock and vibration unit wall mounted with brackets Shock IEC/EN 60068-2-27, 11 ms 50 g
n
Bump IEC/EN 60068-2-29, 11 ms 25 g
n
Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.35 mm/5 g
n
Vibration, random IEC/EN 60068-2-64, 20...500 Hz 0.05 g2/Hz MTBF MIL-HDBK-217E, GB, 40°C >600'000 h
Options
Input and output undervoltage monitoring D1...D5 Output voltage adjustment 10 V...110% of
U
o nom
R Remote on/off S Multi option choice (D1...D5, R, S) via Sub-D connector M1...M2 Built-in second input fuse in the neutral F No fuse fittet (for operation from high DC) F1 System connectors with screw terminals K2
Page 4
4
www.power-one.com
Edition 5/07.2001
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
106.6 (4.2"
)
113.6 (4.47"
)
118 (4.65"
)
103 (4.05"
)
3
(
1.3"
)
9
(
1.93"
)
09107
105 (4.15"
)
Wall mounting brackets (accessory)
Measuring point for case temperature T
C
T
A
A
T
C
Option
M
()
31 (1.22"
)
29.4 (1.16"
)
3
(
1.69"
)
W Series 125 and 250 Watt AC-DC Converters
European Projection
Page 5
5
www.power-one.com
Edition 5/07.2001
1
3
2
S10066
1
35
7
9
11
S10067
2
4
6
8
10
Terminal allocation output side
Pin Des. Single output Double output
1 Earth to load Earth to load 2 + Output pos. Output 1 pos. 3 + Output pos. Output 1 pos. 4 Output neg. Output 1 neg. 5 Output neg. Output 1 neg. 6 + Output pos. Output 2 pos. 7 + Output pos. Output 2 pos. 8 Output neg. Output 2 neg.
9 Output neg. Output 2 neg. 10 Aux. Options Options 11 Earth to load Earth to load
Terminal allocation input side
Pin Des. Determination
1 Protective earth
2NInput neutral
3PInput phase
Accessories
Mounting brackets for vertical chassis/ wall mounting Fixing brackets for enhanced vibrations on DIN-rail Protective covers over input and output terminals
DIN Rail Mountable W Series
Loading...