Datasheet LVD2 Specification

Page 1
FOR USE BY COMPETENT PERSONS
Anyone using this instrument should be knowledgeable and trained about the risks involved with measuring voltage, especially in an industrial setting, and the importance of taking safety precautions and of testing the instrument before and after using it to ensure that it is in good working condition.
LVD2
VoltAlert
Safety Sheet
Read First: Safety Information
WX Warning
To prevent possible electric shock, fi re, or personal injury:
● Use the Product only as specifi ed, or the protection supplied by the Product can be compromised.
● Do not use if the fl ashlight does not operate.
● Detect a known voltage fi rst to make sure that the Product operates correctly.
● When using the Product if tip does not glow, voltage could still be present. The Product indicates active voltage in the presence of electric fi elds of suffi cient strength generated from the source (MAINS) voltage. If the fi eld strength is low, the Product may not provide indication of live voltages. Lack of an indication occurs if the Product is unable to sense the presence of voltage which may be infl uenced by several factors including, but not limited to:
• Shielded wire/cables
• Thickness and type of insulation
• Distance from the voltage source
• Fully-isolated users that prevent an eff ective ground
• Receptacles in recessed sockets/ diff erences in socket design
• Condition of the Product and Batteries
● Disable the Product if it is damaged.
● Do not use the Product if it is damaged.
● Use Product with arrow visible.
● Hold the Product behind the tactile barrier.
● Do not use for dc voltage detection or around voltages exceeding 600 volts, or in the presence of variable motor drives.
● Use caution with voltages above 30 V ac as a shock hazard may exist.
● Do not stare or look directly at the LED fl ash light. The light is extremely bright.
● Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and fl ame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
● Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean with water and get medical aid.
● Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
● Carefully read all instructions.
● Read all safety information before you use the Product.
PN 4572337 September 2014 Rev. 1, 10/19 © 2014 -2019 Fluke Corporation. Specifi cations are subject to change without notice. All rights reserved.
Page 2
For safe operation and maintenance of the product:
● Be sure that the battery polarity is correct to prevent battery leakage.
● Repair the Product before use if the battery leaks.
Symbols
Consult user documentation.
Double Insulated.
T
Hazardous Voltage. Risk of electric shock.
X
Risk of danger. Important information.
W
Conforms to European Union directives
P
Conforms to relevant Canadian and US Standards.
)
Conforms to relevant Australian standards.
This product complies with the WEEE Directive (2002/96/EC) marking
~
requirements. The affi xed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 “Monitoring and Control Instrumentation” product. Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
CAT IV Measurement Category IV is applicable to test and measuring circuits
connected at the source of the building’s low-voltage MAINS installation.
Battery
Safety Specifi cations
Altitude ....................................2000 m
Humidity ..................................80 % for temperatures up to 31 °C decreasing
Electrical supply .....................1.5 Vdc (1 x LR03 ‘AAA’ Battery)
Temperature ............................0 °C to 50 °C
Maximum Voltage to Earth
Ground ....................................600 V
Safety .......................................IEC61010-1:Pollution Degree 2. CAT IV 600V
Electromagnetic
Compatibility ..........................(EMC) IEC 61326-1: Portable Electromagnetic
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or use conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. There may be potential diffi culties in ensuring electromagnetic compatibility in other environments, due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio
linearly to 45 % relative humidity at 50 °C
Environment; IEC 61326-2-2
Page 3
reception in such environments
Contacting Fluke
● Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
● Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
● Canada: 1-800-36-FLUKE (1-800-363-5853)
● Anywhere in the world: +1-425-446-5500
Or, visit Fluke’s website at To register your product, visit To view, print, or download the latest manual supplement, visit
http://us.fl uke.com/usen/support/manuals.
This Fluke product will be free from defects in material and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
11/99
www.fl uke.com.
http://register.fl uke.com.
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands