Datasheet LM385Z-2.5, LM385MX-2.5, LM385M3-2.5, LM385BZ-2.5, LM385BXM-2.5 Datasheet (NSC)

...
Page 1
LM185-2.5/LM285-2.5/LM385-2.5 Micropower Voltage Reference Diode
General Description
The LM185-2.5/LM285-2.5/LM385-2.5 are micropower 2-terminal band-gap voltage regulator diodes. Operating over a 20 µAto20mAcurrent range, they feature exception­ally low dynamic impedance and good temperature stability. On-chip trimming is used to provide tight voltage tolerance. Since the LM-185-2.5 band-gap reference uses only transis­tors and resistors, low noise and good long term stability re­sult.
Careful design of the LM185-2.5 has made the device ex­ceptionally tolerant of capacitive loading, making it easy to use in almost any reference application. The wide dynamic operating range allows its use with widely varying supplies with excellent regulation.
The extremely low power drain of the LM185-2.5 makes it useful for micropower circuitry.This voltage reference can be used to make portable meters, regulators or general purpose analog circuitry with battery life approaching shelf life. Fur­ther, the wide operating current allows it to replace older ref­erences with a tighter tolerance part. For applications requir­ing 1.2V see LM185-1.2.
The LM185-2.5 is rated for operation over a −55˚C to 125˚C temperature range while the LM285-2.5 is rated −40˚C to 85˚C and the LM385-2.5 0˚C to 70˚C. The LM185-2.5/ LM285-2.5 are available in a hermetic TO-46 package and the LM285-2.5/LM385-2.5 are also available in a low-cost TO-92 molded package, as well as S.O. and SOT-23. The LM185-2.5 is also available in a hermetic leadless chip car­rier package.
Features
n
±
20 mV (±0.8%) max. initial tolerance (A grade)
n Operating current of 20 µA to 20 mA n 0.6dynamic impedance (A grade) n Low temperature coefficient n Low voltage reference— 2.5V n 1.2V device and adjustable device also
available— LM185-1.2 series and LM185 series, respectively
Connection Diagrams
TO-92
Plastic Package
DS005519-8
Bottom View
Order Number LM285Z-2.5,
LM285BXZ-2.5, LM285BYZ-2.5
LM385Z-2.5, LM385AXZ-2.5
LM385AYZ-2.5, LM385BZ-2.5,
LM385BXZ-2.5 or LM385BYZ-2.5
See NS Package Number Z03A
SO Package
DS005519-11
Order Number LM285M-2.5,
LM285BXM-2.5, LM285BYM-2.5
LM385M-2.5, LM385BM-2.5
LM385BXM-2.5 or LM385BYM-2.5
See NS Package Number M08A
SOT-23
DS005519-29
*
Pin 3 is attached to the Die Attach Pad (DAP) and should be connected to Pin 2 or left floating.
Order Number LM385M3-2.5
See NS Package Number MA03B
December 1999
LM185-2.5/LM285-2.5/LM385-2.5 Micropower Voltage Reference Diode
© 1999 National Semiconductor Corporation DS005519 www.national.com
Page 2
Connection Diagrams (Continued)
LCC
Leadless Chip Carrier
DS005519-14
Order Number LM185E-2.5/883
See NS Package Number E20A
TO-46
Metal Can Package
DS005519-13
Bottom View
Order Number LM185H-2.5,
LM185H-2.5/883, LM185BXH-2.5,
LM185BXH-2.5/883, LM185BYH-2.5,
LM185BYH2.5/883, LM285H-2.5,
or LM285BYH-2.5
See NS Package Number H02A
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 2
Page 3
Absolute Maximum Ratings (Notes 1, 2)
If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications.
Reverse Current 30 mA Forward Current 10 mA Operating Temperature Range (Note 3)
LM185-2.5 −55˚C to + 125˚C LM285-2.5 −40˚C to + 85˚C LM385-2.5 0˚C to 70˚C
Storage Temperature −55˚C to + 150˚C
Soldering Information
TO-92 Package (10 sec.) 260˚C TO-46 Package (10 sec.) 300˚C SO and SOT Package
Vapor Phase (60 sec.) 215˚C Infrared (15 sec.) 220˚C
See AN-450 “Surface Mounting Methods and Their Effect on Product Reliability” for other methods of soldering surface mount devices.
Electrical Characteristics
(Note 4)
Parameter Conditions Typ
LM385A-2.5
Units
(Limits)
LM385AX-2.5 LM385AY-2.5
Tested Design
Limit Limit
(Note 5) (Note 6)
Reverse Breakdown I
R
=
100 µA 2.500 2.480 V(Min)
Voltage 2.520 V(Max)
2.500 2.470 V(Min)
2.530 V(Max)
Minimum Operating 12 18 20 µA Current (Max) Reverse Breakdown I
MIN
IR≤ 1mA 1 1.5 mV Voltage Change with (Max) Current 1 mA I
R
20 mA 10 20 mV
(Max)
Reverse Dynamic I
R
=
100 µA, 0.2 0.6 Impedance f=20 Hz 1.5 Wideband Noise (rms) I
R
=
100 µA 120 µV
10 Hz f 10 kHz
Long Term Stability I
R
=
100 µA,
T=1000 Hr, 20 ppm T
A
=
25˚C
±
0.1˚C
Average Temperature I
MIN
IR≤ 20 mA
Coefficient (Note 7) X Suffix 30 ppm/˚C
Y Suffix 50 (Max) All Others 150
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com3
Page 4
Electrical Characteristics (Continued)
LM185-2.5 LM185BX-2.5 LM385B-2.5 LM185BY-2.5 LM385BX-2.5 LM385-2.5 Units
LM285-2.5 LM385BY-2.5 (Limit)
Parameter Conditions Typ LM285BX-2.5
LM285BY-2.5
Tested Design Tested Design Tested Design
Limit Limit Limit Limit Limit Limit
(Note 5) (Note 8)
(Note 6) (Note 5) (Note 6) (Note 5) (Note 6)
Reverse Breakdown T
A
=
25˚C, 2.5 2.462 2.462 2.425 V(Min)
Voltage 20 µA I
R
20 mA 2.538 2.538 2.575 V(Max)
Minimum Operating Current
13 20 30 20 30 20 30 µA
(Max)
LM385M3-2.5 15 20
Reverse Breakdown Voltage Change with Current
20 µA I
R
1mA 1 1.5 2.0 2.5 2.0 2.5 mV
(Max)
1mAI
R
20 mA 10 20 20 25 20 25 mV
(Max)
Reverse Dynamic I
R
=
100 µA, 1 Impedance f=20 Hz Wideband Noise (rms) I
R
=
100 µA, 120 µV
10 Hz f 10 kHz
Long Term Stability I
R
=
100 µA,
T=1000 Hr, 20 ppm T
A
=
25˚C
±
0.1˚C
Average Temperature I
R
=
100 µA Coefficient (Note 7) X Suffix 30 30 ppm/˚C
Y Suffix 50 50 ppm/˚C All Others 150 150 150 ppm/˚C
(Max)
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is in­tended to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed.
Note 2: Refer to RETS185H-2.5 for military specifications. Note 3: For elevated temperature operation, T
J MAX
is: LM185 150˚C LM285 125˚C LM385 100˚C
Thermal Resistance TO-92 TO-46 SO-8 SOT-23
θ
ja
(Junction to Ambient) 180˚C/W (0.4" Leads) 440˚C/W 165˚C/W 283˚C/W
170˚C/W (0.125" Leads)
θ
jc
(Junction to Case) N/A 80˚C/W N/A N/A
Note 4: Parameters identified with boldface type apply at temperature extremes. All other numbers apply at T
A
=
T
J
=
25˚C.
Note 5: Guaranteed and 100%production tested. Note 6: Guaranteed, but not 100%production tested. These limits are not used to calculate average outgoing quality levels. Note 7: The average temperature coefficient is defined as the maximum deviation of reference voltage at all measured temperatures between the operating T
MAX
and T
MIN
, divided by T
MAX–TMIN
. The measured temperatures are −55˚C, −40˚C, 0˚C, 25˚C, 70˚C, 85˚C, 125˚C.
Note 8: A military RETS electrical specification available on request.
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 4
Page 5
Typical Performance Characteristics
Applications
LM385-2.5 Applications
Reverse Characteristics
DS005519-15
Reverse Characteristics
DS005519-16
Forward Characteristics
DS005519-17
Temperature Drift
DS005519-18
Reverse Dynamic Impedance
DS005519-19
Reverse Dynamic Impedance
DS005519-20
Noise Voltage
DS005519-21
Filtered Output Noise
DS005519-22
Response Time
DS005519-23
Wide Input Range Reference
DS005519-12
Micropower Reference from 9V Battery
DS005519-2
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com5
Page 6
LM385-2.5 Applications (Continued)
Micropower 5V Reference (Note 9)
DS005519-9
Note 9: I
Q
40 µA
Micropower 10V Reference (Note 10)
DS005519-10
Note 10: I
Q
30 µA standby current
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 6
Page 7
LM385-2.5 Applications (Continued)
Precision 1 µA to 1 mA Current Sources
DS005519-24
DS005519-25
METER THERMOMETERS
0˚C–100˚C Thermomemter
DS005519-26
Calibration
1. Short LM385-2.5, adjust R3 for I
OUT
=
temp at 1µA/˚K
2. Remove short, adjust R2 for correct reading in centi­grade
0˚F–50˚F Thermomemter
DS005519-27
Calibration
1. Short LM385-2.5, adjust R3 for I
OUT
=
temp at 1.8 µA/˚K
2. Remove short, adjust R2 for correct reading in ˚F
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com7
Page 8
LM385-2.5 Applications (Continued)
Seebeck Voltage Voltage
Thermocouple Co- R1 R2 Across R1 Across R2
Type efficient ()()
@
25˚C (mV)
(
µ
V/˚C) (mV)
J 52.3 523 1.24k 15.60 14.32 T 42.8 432 1k 12.77 11.78 K 40.8 412 953 12.17 11.17 S 6.4 63.4 150 1.908 1.766
Typical supply current 50 µA
Micropower Thermocouple Cold Junction
Compensator
DS005519-6
Adjustment Procedure
1. Adjust TC ADJ pot until voltage across R1 equals Kelvin temperature multiplied by the thermocouple Seebeck coefficient.
2. Adjust zero ADJ pot until voltage across R2 equals the thermocouple Seebeck coefficient multiplied by 273.2.
Improving Regulation of Adjstable Regulators
DS005519-7
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 8
Page 9
Schematic Diagram
DS005519-1
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com9
Page 10
Physical Dimensions inches (millimeters) unless otherwise noted
Order Number LM185E-2.5/883
NS Package Number E20A
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 10
Page 11
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
TO-46 Metal Can Package (H)
Order Number LM185H-2.5, LM185H-2.5/883, LM185BXH-2.5, LM185BXH-2.5/883,
LM185BYH-2.5, LM185BYH-2.5/883, LM285H-2.5, or LM285BYH-2.5
NS Package Number H02A
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com11
Page 12
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
SOT-23 Package (M3)
Order Number LM385M3-2.5
NS Package Number MA03B
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com 12
Page 13
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
Small Outline (SO-8) Package (M)
Order Number LM285M-2.5, LM285BXM-2.5, LM285BYM-2.5,
LM385M-2.5, LM385BM-2.5, LM385BXM-2.5 or LM385BYM-2.5
NS Package Number M08A
LM185-2.5/LM285-2.5/LM385-2.5
www.national.com13
Page 14
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
National Semiconductor Corporation
Americas Tel: 1-800-272-9959 Fax: 1-800-737-7018 Email: support@nsc.com
National Semiconductor Europe
Fax: +49 (0) 1 80-530 85 86
Email: europe.support@nsc.com Deutsch Tel: +49 (0) 1 80-530 85 85 English Tel: +49 (0) 1 80-532 78 32 Français Tel: +49 (0) 1 80-532 93 58 Italiano Tel: +49 (0) 1 80-534 16 80
National Semiconductor Asia Pacific Customer Response Group
Tel: 65-2544466 Fax: 65-2504466 Email: sea.support@nsc.com
National Semiconductor Japan Ltd.
Tel: 81-3-5639-7560 Fax: 81-3-5639-7507
www.national.com
TO-92 Plastic Package (Z)
Order Number LM285Z-2.5, LM285BXZ-2.5, LM285BYZ-2.5,
LM385Z-2.5, LM385AXZ-2.5, LM385AYZ-2.5,
LM385BZ-2.5, LM385BXZ-2.5 or LM385BYZ-2.5
NS Package Number Z03A
LM185-2.5/LM285-2.5/LM385-2.5 Micropower Voltage Reference Diode
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
Loading...