• Rugged electrical and mechanical design
• Integrated power factor correction
• Operating ambient temperature range –40...71 °C with convection cooling
Input voltage range from 85...255 V AC 1or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage
LGA
Selection chart
Output 1 Output 2 Input voltage Efficiency Type Options
U
o nomIo nom
U
o nomIo nom
U
i
h
min
[V DC] [A] [V DC] [A] [V AC] [%]
5.1 25 - - 85...255 78 LK 4003-6R -9, E, D, V, P, T, B1 12 12 - - 85...255 85 LK 4301-7R -9, E, D, P, T, B1 15 10 - - 85...255 85 LK 4501-7R -9, E, D, P, T, B1 24 6 - - 85...255 86 LK 4601-7R -9, E, D, P, T, B1
24 6 - - 85...255 83 LK 5320-7R -9, E, D, P, T, B1 30 5 - - 85...255 83 LK 5540-7R -9, E, D, P, T, B1 48 3 - - 85...255 84 LK 5660-7R -9, E, D, P, T, B1
12 6 12 6 85...255 83 LK 5320-7R -9, E, D, P, T, B1 15 5 15 5 85...255 83 LK 5540-7R -9, E, D, P, T, B1 24 3 24 3 85...255 84 LK 5660-7R -9, E, D, P, T, B1
Page 2
2
www.power-one.com
Edition 4/04.2001
Input
Input voltage AC wide input range 85...255 V AC Input frequency 50/60 Hz Power factor per IEC/EN 61000-3-2 >95% Inrush current limitation by thermistor
Output
Efficiency
U
i nom
,
I
o nom
up to 86 %
Output voltage setting accuracy
U
i nom
,
I
o nom
±0.6%
U
o nom
Output voltage switching noise IEC/EN 61204, total typ. 100 mV
pp
Line regulation
U
i min
...
U
i max
,
I
o nom
typ. ±0.1%
Load regulation
U
i nom
, 0.1...
I
o nom,
symmetrical output load typ. 0.4% Minimum load not required 0 A Current limitation rectangular U/I characteristic typ. 110...100%
I
o nom
Operation in parallel by current limitation Hold-up time
U
i nom
,
I
o nom
20 ms
Control and protection
Input fuse not user accessible 4 AT Input undervoltage lockout typ. 80%
U
i min
Input overvoltage lockout typ. 115%
U
i max
Input transient protection varistor Output no-load, overload and short circuit proof Output overvoltage suppressor diode in each output typ. 130%
U
o nom
Overtemperature switch-off with auto restart
T
C
typ. 100 °C
Output voltage adjustment 0...110%
U
o nom
Inhibit TTL input, output(s) disabled if open circuit Status indication LEDs: OK, inhibit, overload
Safety
Approvals EN 60950, UL 1950, CSA 22.2 No. 950 Class of equipment class I Protection degree IP 30 Electric strength test voltage I/case 2 kV AC
I/O 4 kV AC O/case 1 kV AC O/O 0.1 kV AC
EMC
Electrostatic discharge IEC/EN 61000-4-2, level 4 (8/15 kV) criterion A Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A Electr. fast transients/bursts IEC/EN 61000-4-4, level 4 (2/4 kV) criterion A Surge IEC/EN 61000-4-5, level 3 (2 kV) criterion A Conducted disturbances IEC/EN 61000-4-6, level 3 (10 V) criterion A Electromagnetic emissions CISPR 22/EN 55022 class B
Cassette Style K Series with PFC
Page 3
3
www.power-one.com
Edition 4/04.2001
Environmental
Operating ambient temperature
U
i nom
,
I
o nom
, convection cooled –25...71°C
Operating case temperature
TCU
i nom
,
I
o nom
–25...95°C Storage temperature non operational –40...100°C Damp heat IEC/EN 60068-2-3, 93%, 40 °C 56 days Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.35 mm/5 g
n
Shock IEC/EN 60068-2-27, 6 ms 100 g
n
Bump IEC/EN 60068-2-29, 6 ms 40 g
n
Random vibration IEC/EN 60068-2-64, 20...500 Hz 4.9 g
n rms
MTBF MIL-HDBK-217F, GB, 40°C 514'000 h
Options
Extended temperature range –40...71°C, ambient, operating -9 Electronic inrush current limitation E Output voltage adjustment 40...100%
U
o nom
, excludes feature R and vice versa P Input and/or output undervoltage monitoring, excludes option V D0…D9 Input and/or output undervoltage monitoring (VME), excludes option D V0, V2, V3 Current sharing T Cooling plate B1
32 28 24 20 16 12 8 4
Connector type H15
S10010
30 26 22 18 14 10 6
Pin allocation
Pin LK 4003 LK 4301, LK 4501, LK 4601 LK 5000
4 Vo1+ Output 1 Vo1+ Output 1 Vo2+ Output 2 6 Vo1+ Vo2+
8 Vo1– Output 1 Vo1– Output 1 Vo2– Output 2 10 Vo1– Vo2– 12 S+ Sense S+ Sense Vo1+ Output 1 14 S– Sense S– Sense Vo1– Output 1 16 R Control of
U
o1
R Control of
U
o1
R Control of
U
o1
18 i Inhibit i Inhibit i Inhibit 20 D Save data D Save data D Save data
V ACFAIL 22 T Current sharing T Current sharing T Current sharing 24 Protective earth Protective earth Protective earth 26 N Input N Input N Input or Neutral 28 N N 30 P Input P Input P Input or Phase 32 P P
4/630/32
Type H15 S2
10001
Page 4
4
www.power-one.com
Edition 4/04.2001
Cassette Style K Series with PFC
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
European Projection
Accessories
Front panels 19" (Schroff/Intermas) Mating H15/H15S4 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting
159 (6.25")
4.5 (0.18")
89 (3.50")
111 (3U) (4.37")
168.5 (6.63")
80 (3.15")
6.5 (0.26")
7 TE
9 TE
Measuring point of case temperature
T
C
171.93 (6.77") (DIN 41494)
50 (1.97")
S09002
Test jacks Option P (Uo)
Option D (Uti)
LED OK
LED i
LED IoL
Option D (Uto)
Loading...