POWR-GARD® Blocks and Holders Datasheet
TO LOAD
TO
SOURCE
ELECTRICAL TAPE
IMPROVED
Description
Recently redesigned, the Littelfuse 600 V in-line watertight fuse holders allow maximum protection for high humidity and corrosive environments. The fuse holders are designed to be touch-safe and flexible for use in a variety of applications. See the list below for the redesigned part numbers.
Applications
• Street lighting and parking lot lighting
• Sports lighting and various outdoor illuminated signs
• Boat electrical circuits, tractors/yard equipment and
general outdoor circuit protection (such as traffic signals, alley lighting and electric wheelchairs)
LEB/LEX
LEC/LEY
Specifications
Voltage rating 600 V Ampere rating up to 30 A Interrupting rating 200 kA rms symmetrical (with Class CC fuses) Approvals LEB/LEX series UL Recognized Miscellaneous
Fuse holder per UL UL 4248 (File: E14721) CSA Certified per C22.2, No. 39 (File: LR7316) LEC/LEY series UL Listed Class CC Branch Circuit Fuse holder per UL 512 (File: E14721) CSA Certified per C22.2, No. 39 (File: LR7316)
Features/Benefits
• Design increases safety by facilitating individual device disconnection for easy servicing, eliminating shock risk
• Increases efficiency by preventing faulted ballast from severely damaging fixture or device
• Designed to meet IP67 touch-safe standards
• Watertight o-ring seal
• Variety of terminations available for flexible design
• Insulating boots available for harsh environments
Recommended Fuses
LEB/LEX series:
Class CC Series: CCMR, KLDR, KLKR Midget Series: BLF, BLN, FLM, FLQ, KLK, KLKD
LEC/LEY series: Class CC Series: CCMR, KLDR, KLKR
Web Resources
Sample requests, downloadable CAD drawings and other technical information: littelfuse.com/in-line
Look for these part numbers featuring our improved design
• Better surface area for ergonomic comfort, improved grip and better torque
• More pronounced seating – automatically seats as user begins twisting
• Chamfered edges for additional installation comfort
BASE PART
NUMBER
LEB-AA 0LEB00AAX 0LEB00AAXK
LEB-AA-S 0LEB0AASX 0LEB0AASXK
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
1 of 6
LEB-AB 0LEB00ABX 0LEB00ABXK
LE B-AYC-S 0LEBAYCSX 0LEBAYCSXK
LEB-BB 0LEB00BBX 0LEB00BBXK
LEB-JJ 0LEB00JJX 0LEB00JJXK
LEB-JJ-S 0LEB0JJSX 0LEB0JJSXK
PREVIOUS ORDERING
NUMBER
NEW ORDERING
NUMBER
Rev: 012414
Page 2
POWR-GARD® Blocks and Holders Datasheet
4.5"
10.3"
( ASSEMBLED LENGTH )
5.4"
( ASSEMBLED LENGTH )
4.5"
9.3"
( ASSEMBLED LENGTH )
WPB1 BOOT (OPTIONAL)
WPB1 BOOT (OPTIONAL)
INSULATING BOOT
(STANDARD)
INSULATING BOOT
(STANDARD)
4.2"
4.5"
9.3"
( ASSEMBLED LENGTH )
10.3"
( ASSEMBLED LENGTH )
5.3"
( ASSEMBLED LENGTH )
Ordering Information
To order Littelfuse in-line fuse holders by part number, refer to the charts on the next page.
LEB - AA - S
Littelfuse Series
Load Side/Terminal Size
SERIES DESCRIPTION
LEB One-pole in-line fuse holder for Midget and Class CC fuses
LEC One-pole in-line fuse holder for Class CC fuses
LET
One-pole in-line fuse holder with
permanently installed solid neutral
LEX Two-pole in-line fuse holder for Midget and Class CC fuses
LEY Two-pole in-line fuse holder for Class CC fuses
Breakaway Feature
Line Side/Terminal Size
A & B Crimp Terminal
C & D Crimp Terminal
Recommended Crimping Tools
The following crimping tools or equivalents may be used on either the non-breakaway or breakaway watertight in-line fuse holders.
TERMINAL SIZE T&B PART NUMBER BURNDY PART NUMBER
A WT161M –
B WT161M MR4C
C M5-GREY Hypress Y34A
D M5-BROWN Hypress Y34A
Dimensions Inches
1-Pole
1-Pole Breakaway
J Terminal
Y Terminal
Insulating Boots
• Molded from engineering-grade thermoplastics which provide high resistance to corrosive environments
• For watertight protection of non-breakaway Y-pole termination, order one WPB1 and one WPB3 boot
ORDERING NUMBER TERMINAL TYPE
WPB1 A, B, C, D, J
WPB3 Y
2-Pole
2-Pole Breakaway
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
2 of 6
Rev: 012414
Page 3
POWR-GARD® Blocks and Holders Datasheet
Ordering Information (1-Pole LEB/LEC and 2-Pole LEX/LEY for Class CC and Midget Fuses)
SINGLE POLE DOUBLE POLE LOAD TERMINAL SELECTION LINE TERMINAL SELECTION
STANDARD
PART
NUMBER
LEB-AA LEC-AA
LEB-AB LEC-AB
LEB-AC LEC-AC
LEB-AD LEC-AD
LEB-AJ LEC-AJ
LEB-AYC LEC-AYC
LEB-BA LEC-BA
LEB-BB LEC-BB
LEB-BC LEC-BC
LEB-BD LEC-BD
LEB-BJ LEC-BJ
LEB-BYC LEC-BYC
LEB-CA LEC-CA
LEB-CB LEC-CB
LEB-CC LEC-CC
LEB-CD LEC-CD
LEB-CJ LEC-CJ
LEB-CYC LEC-CYC
LEB-DA LEC-DA
LEB-DB LEC-DB
LEB-DC LEC-DC
LEB-DD LEC-DD
LEB-DJ LEC-DJ
LEB-DYC LEC-DYC
LEB-JJ LEC-JJ
LEB-JYC LEC-JYC
BREAKAWAY
PART
NUMBER
LEB-AA-S LEC-AA-S
LEB-AB-S LEC-AB-S
— —
— —
LEB-AJ- S LEC-AJ-S
LEB-AYC-S LEC-AYC-S
LEB-BA-S LEC-BA-S
LEB-BB-S LEC-BB-S
— —
— —
LEB-BJ-S LEC-BJ-S
LEB-BYC-S LEC-BYC-S
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
LEB-JJ-S LEC-JJ-S
LEB-JYC-S LEC-JYC-S
STANDARD
PART
NUMBER
LEX-AA LEY-AA
LEX-AB LEY-AB
LEX-AC LEY-AC
LEX-AD LEY-AD
LEX-AYC
LEY-AYC
LEX-BA LEY-BA
LEX-BB
LEY-BB
LEX-BC
LEY-BC
LEX-BD LEY-BD
LEX-BYC
LEY-BYC
LEX-CA LEY-CA
LEX-CB
LEY-CB
LEX-CC
LEY-CC
LEX-CD LEY-CD
LEX-CJ LEY-CJ
LEX-CYC
LEY-CYC
LEX-DA LEY-DA
LEX-DB LEY-DB
LEX-DC LEY-DC
LEX-DD LEY-DD
LEX-DJ
LEY-DJ
LEX-DYC LEY-DYC
LEX-JJ LEY-JJ
BREAKAWAY
PART
NUMBER
LEX-AA-S LEY-AA-S
LEX-AB-S LEY-AB-S
—
— —
— —
LEX-AYC-S LEY-AYC-S
LEX-BA-S LEY-BA-S
LEX-BB-S
LEY-BB-S
— —
— —
— —
— —
— —
LEX-BYC-S LEY-BYC-S
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
LEX-JJ-S LEY-JJ-S
— —
TERMINAL
TYPE
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
Copper
Set-Screw
WIRE SIZE
#12 to #8
#12 to #8
#12 to #8
#12 to #8
#12 to #8
#12 to #8
#12 to #8 #10 to #211
#12 to #8 #10 to #211
RANGE
#12
#12
#12
#12
#12
#12 #10
#6 #4
#10
#6 #4
#10
#6 #4
#10
#6 #4
#10
#6 #4
#10
#6 #4
#8 #4
#8 #4
#8 #4
#8 #4
#8 #4
#8 #4
#6 #2
#6 #2
#6 #2
#6 #2
#6 #2
#6 #2
WIRES PER
TERMINAL
SOLID
STRANDED
WIRE
1 2
1 2
1 2
1 2
1 2
1 2
2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
2 1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
•
—
•
•
—
•
•
—
•
•
—
•
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
—
•
•
•
—
TERMINAL
WIRE
—•Copper
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
TYPE
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
"Y" Type
Copper
Set-Screw
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
"Y" Type
Copper
Set-Screw
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
"Y" Type
Copper
Set-Screw
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
"Y" Type
Copper
Set-Screw
Set-Screw
"Y" Type
Copper
Set-Screw
WIRE SIZE
#12 to #8
#12 to #8 #10 to #211
#12 to #8 #10 to #211
#12 to #8
#12 to #8
#10 - #2
#12 to #8
#10 - #2
#12 to #8
#12 to #8
#10 - #2
#12 to #8 #10 to #211
#12 to #8
#12 to #8
#10 - #8
#12 to #8 #10 to #811
#12 to #8 #10 to #211
#12 to #8 #10 to #211
RANGE
#12 #10
#6 #4
#8 #4
#6 #2
#12 #10
#6 #4
#8 #4
#6 #2
#12 #10
#6 #4
#8 #4
#6 #2
#12 #10
#6 #4
#8 #4
#6 #2
WIRES PER
TERMINAL
1 2
2 1 1
2 1
2 1
1 2
2 1 1
2 1
2 1
1 1
1 1
1 2
2 1 1
2 1
2 1
1 1
1 2
2 1 1
2 1
2 1
2 1
SOLID
WIRE
•
•
•
•
—
•
—
•
—
•
—
•
—
•
•
•
•
—
•
—
•
—
•
—
•
—
•
•
•
•
—
•
—
•
—
•
—
•
—
•
•
•
•
—
•
—
•
—
•
—
•
—
•
—
•
—
STRANDED
WIRE
•
•
•
•
•
•
•
•
•
—
•
—
•
•
•
•
•
•
•
•
•
•
—
•
—
•
•
•
•
•
•
•
•
•
•
•
•
—
•
—
•
•
•
•
•
•
•
•
•
•
—
•
—
•
—
•
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
3 of 6
Rev: 012414
Page 4
POWR-GARD® Blocks and Holders Datasheet
Ordering Information (Solid Neutral LET Fuse Holders)
LOAD TERMINAL SELECTION LINE TERMINAL SELECTION
STANDARD
NUMBER
PART
BREAKAWAY
PART
NUMBER
FUSE TYPE
TERMINAL
TYPE
WIRE SIZE
RANGE
WIRES PER
TERMINAL
SOLID
WIRE
STRANDED
WIRE
TERMINAL
TYPE
WIRE SIZE
RANGE
WIRES PER
TERMINAL
SOLID
WIRE
STRANDED
WIRE
LET-AA LET-AA-S
LET-AB LET-AB-S
LET-AYC LET-AYC-S
LET-BA LET-BA-S
LET-BB LET-BB-S
LET-BYC LET-BYC-S
LET-JJ LET-JJ-S
LET-JYC LET-JYC-S
Solid
Neutral
Solid
Neutral
Solid
Neutral
Solid
Neutral
Solid
Neutral
Solid
Neutral
Solid
Neutral
Solid
Neutral
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
Copper
Set-Screw
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#10
#6 #4
#10
#6 #4
#10
#6 #4
#12 to #8 #10 to #2
#12 to #8 #10 to #2
1 2
1 2
1 2
2 1 1
2 1 1
2 1 1
1 1
1 1
•
•
•
•
•
•
•
•
—
•
•
—
•
•
—
•
—
•
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
—
•
Copper
Crimp
Copper
Crimp
“Y” Type
Copper
Set-Screw
Copper
Crimp
Copper
Crimp
“Y” Type
Copper
Set-Screw
Copper
Set-Screw
“Y” Type
Copper
Set-Screw
#12 to #8
#12
#10
#6 #4
#12 to #8 #10 to #2
#12 to #8
#12
#10
#6 #4
#12 to #8 #10 to #2
#12 to #8 #10 to #2
#12 to #8 #10 to #2
1 2
2 1 1
1 1
1 2
2
1 1
1 1
1 1
1 1
•
•
•
•
—
•
—
•
•
•
•
—
•
—
•
—
•
—
•
•
•
•
•
—
•
•
•
•
•
•
—
•
—
•
—
•
Ordering Information (Terminals)
TERMINAL DESIGNATION TERMINAL DESCRIPTION WIRES PER TERMINAL WIRE RANGE SOLID WIRE STRANDED WIRE
A Copper Crimp
B Copper Crimp
C Copper Crimp
D Copper Crimp
J Copper Set-Screw
Y (2 terminals) “Y” Style Copper Set-Screw
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
1 #12-#8 • • 2 #12 • • 2 #10 • • 1 #6 1 #4 2 #8 • •
1 #4 — • 2 #6 • • 1 #2 — • 1 #12-#8 • — 1 #10-#2 — • 1 #12-#8 • — 1 #10-#2 — •
•
—
4 of 6
•
•
Rev: 012414
Page 5
POWR-GARD® Blocks and Holders Datasheet
IN-LINE WATERTIGHT FUSE HOLDERS
Two-Pole Breakaway Holder
Features/Benefits
• LEXT-YY version has a permanently installed “neutral” slug to prevent the neutral from accidentally being fused
• LEX-YYC version allows for fusing of line-to-line loads or other applications requiring two fuses to disconnect under strain
• Fiberglass polymer body resists damage from impact
• Four “Y” type set-screw terminals accommodate a wide
range of solid and stranded Cu or Al conductors
• O-ring and terminal boots form watertight seal, preventing leakage
Specifications
Description
Littelfuse LEXT-YY-S and LEX-YYC-S series breakaway fuse holders meet state and federal highway commission safety standards requiring fuse holders to readily disconnect from power in case of a pole knockdown.
The breakaway feature consists of a receptacle permanently attached to the power line and a fuse holder with matching terminals. If a knockdown occurs, the parts separate, leaving the energized conductor recessed and unexposed.
Ordering Information
LOAD TERMINAL SELECTION LINE TERMINAL SELECTION
Part numbers LEXT-YY-S (Solid neutral)
LEX-YYC-S
Voltage Rating 600 VAC/VDC Ampere Rating 30 A Interrupting Rating 200 kA with Class CC Fuses Y Terminals Tin Plated Copper w/ set screws Wire Size 1 solid #12 to #8 or
1 stranded #10 to #2
Approvals UL Recognized (File: E14721) CSA Certified (File: LR7316)
Applications
• Street lighting
• Marinas
• Travel trailer parks
• Physically strained fuse holders applications
Web Resources
Additional technical information:
littelfuse.com/In-Line
ORDERING
NUMBER
LEXTYYS LEXT0YYSX
LEXYYCS 0LEXYYCSX
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
FUSE TYPE
Midget
Class CC
Midget
Class CC
TERMINAL
TYPE
“Y” type
Copper
Set-Screw
“Y” type
Copper
Set-Screw
WIRE SIZE
RANGE
#12 to #8 1 • —
#10 to #2 1 — • 1 — •
#12 to #8
#10 to #2
WIRES PER
TERMINAL
SOLID
WIRE
1 • —
1 — • 1 — •
5 of 6
WIRE
STANDARD
TERMINAL
TYPE
“Y” type
Copper
Set-Screw
“Y” type
Copper
Set-Screw
WIRE SIZE
RANGE
#12 to #8
#10 to #2
#12 to #8
#10 to #2
WIRES PER
TERMINAL
1 • —
1 • —
SOLID
WIRE
Rev: 012414
STANDARD
WIRE
Page 6
POWR-GARD® Blocks and Holders Datasheet
4 9/16"
( ASSEMBLED LENGTH )
11 1/4"
( ASSEMBLED LENGTH )
5 1/8"
( ASSEMBLED LENGTH )
IN-LINE WATERTIGHT FUSE HOLDERS
Two-Pole Breakaway Holder
Dimensions Inches
LEXT-YY-S
LEX-YY-C-S
PERMANENT
NEUTRAL SLUG
4 9/16"
( ASSEMBLED LENGTH )
5 1/8"
( ASSEMBLED LENGTH )
11 1/4"
( ASSEMBLED LENGTH )
4 9/16"
( ASSEMBLED LENGTH )
5 1/8"
( ASSEMBLED LENGTH )
11 1/4"
( ASSEMBLED LENGTH )
Recommended Fuses
Class CC Series: CCMR, KLDR, KLKR Midget Series: BLF, BLN, FLM, FLQ, KLK, KLKD
Four WPB3 insulating boots come standard with the LEXT-YY-S and LEX-YY-C-S fuse holders. Molded from non-conductive engineering grade thermoplastic to deliver a watertight seal in corrosive environments, they can be trimmed to the specific conductor size insuring a snug fit.
littelfuse.com © 2014 Littelfuse POWR-GARD® Products
6 of 6
Rev: 012414
Loading...