Datasheet LC4100C Datasheet (SANYO)

Page 1
Overview
The LC4100C is a common driver for large-scale dot matrix LCD panels. It includes a 240-bit bidirectional shift register and 4-level LCD driver circuits. The number of bits can be further increased by using the provided input and output pins to connect multiple LC4100Cs in cascade. The LC4100C and LC4101C form a large-screen LCD panel driver chip set.
Features
• Fabricated in a CMOS (P-sub) high-voltage process.
• LCD drive voltage: 36 V
• Logic system power-supply voltage: 3.0 to 5.5 V
•f
load
max: 1 MHz
• Slim chip (output pads are concentrated on one of the longer sides)
• 240 outputs (pad pitch: 70 µm)
• Bidirectional shift register
• The shift register can be split into two 120-bit registers.
• DISPOFF function that locks the drive voltages output to the LCD at fixed levels.
• Display duty: 1/160 to 1/480
CMOS LSI
93096HA (OT)/31596HA (OT) No. 5279-1/8
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
LCD Dot Matrix Common Driver
for STN Displays
LC4100C
Ordering number : EN5279B
Parameter Symbol Conditions Ratings Unit
V
DD
–0.3 to +7 V
Supply voltage V
EEn
–0.3 to +40 V
V
SSn
–0.3 to +0.3 V
V
IN
LOAD, L/R, DISP, DF, EIO1, EIO3, EIO4 –0.3 to VDD+ 0.3 V
Input voltage
V
0
, V
1
VEE– 7 to VDD+ 0.3 V
V
4
–0.3 to VSS+7 V
V
5
–0.3 to +0.3 V Operating temperature Topr –20 to +75 °C Storage temperature Tstg –55 to +125 °C
Specifications
Absolute Maximum Ratings at Ta = 25°C ± 2°C, standard VSS, V
EEn
= V
EE1
or V
EE2
, V
SSn
= V
SS1
or V
SS2
Note: The voltages V1, V2, V3, V4, and V5must obey the relationships V
EEn
+ 0.3 V0≥ V1≥ VEE– 7, and 7 V4≥ V5≥ V
SSn
– 0.3. (Unit: V)
Page 2
No. 5279-2/8
LC4100C
Parameter Symbol Conditions
Ratings
Unit
min typ max
V
DD
3.0 5.5 V
Supply voltage V
EEn
20 36 V
V
SSn
0 V
Input high-level voltage V
IH
LOAD, L/R, DISP, DF, EIO1, EIO3, EIO4 0.8 V
DD
V
DD
V
Input low-level voltage V
IL
LOAD, L/R, DISP, DF, EIO1, EIO3, EIO4 0 0.2 V
DD
V
V
0
, V1V0, V
1
V
EEn
– 7 V
EEn
V
Input voltage V
4
V
4
0 V
EEn
+ 7 V
V
5
V
5
0 V
Clock frequency f
load
LOAD 1 MHz
V
DD
=
High-level clock
t
w (ldh)
LOAD 50 ns
5 V ± 10%
pulse width EIO input setup time t
su (ei)
LOAD, EIO1, EIO3, EIO4 100 ns
EIO input hold time t
ho (ei)
LOAD, EIO1, EIO3, EIO4 30 ns
Clock frequency f
load
LOAD 200 kHz
V
DD
=
High-level clock
t
w (ldh)
LOAD 120 ns
3 to 4.5 V
pulse width EIO input setup time t
su (ei)
LOAD, EIO1, EIO3, EIO4 120 ns
EIO input hold time t
ho (ei)
LOAD, EIO1, EIO3, EIO4 40 ns
Allowable Operating Ranges at Ta = –20 to +75°C, standard VSS, V
EEn
= V
EE1
or V
EE2
, V
SSn
= V
SS1
or V
SS2
Parameter Symbol Conditions
Ratings
Unit
min typ max
Input high-level current I
IH
VIN= VDD: LOAD, L/R, DISP, DF, EIO1, EIO3, EIO4 1 µA
Input low-level current I
IL
VIN= VSS: LOAD, L/R, DISP, DF, EIO1, EIO3, EIO4 –1 µA
Output high-level voltage V
OH
IO= –0.4 mA: EIO1, EIO4 0.8 V
DD
V
DD
V
Output low-level voltage V
OL
IO= 0.4 mA: EIO1, EIO4 V
SS
0.2 V
DD
V
V
EE1
, V
EE2
= 20 V, V0= 20 V, V0– V0= 0.5 V,
Output on resistance R
OUT
V1= 20 V, V1– V0= 0.5 V, V4= 0 V, V0– V4= 0.5 V, 0.3 0.6 k V
5
= 0 V, V0– V5= 0.5 V: OUT1 to OUT240
Current drain (1) I
DD
VDD= 3 to 5.5 V, fcp= 50 kHz, fDF= 100 Hz,
300 µA
with no output load
Current drain (2) I
EE
V
EEn
= 36 V, 1 data shift 750 µA
Electrical Characteristics at Ta = –20 to +75°C, standard VSS, VDD= 3 to 5.5 V
Note: 1. The voltages V1, V2, V3, V4, and V5must obey the relationships V
EEn
V0≥ V1≥ VEE– 7, and 7 V4≥ V5≥ V
SSn
. (Unit: V)
2. When turning on the power supplies, first turn on the logic system power supply and then turn on the high-voltage system power supply; alternatively, turn both on at the same time. When turning off the power supplies, first turn off the high-voltage system power supply and then turn off the logic system power supply; alternatively, turn both off at the same time.
Page 3
Block Diagram
No. 5279-3/8
LC4100C
Parameter Symbol Conditions
Ratings
Unit
min typ max
EIO output delay time t
d (eo)
30 pF capacitance load: LOAD, EIO1, EIO4 180 ns
LOAD-OUTn delay time t
d (ldo)
100 pF capacitance load: LOAD, OUTn 700 ns
DF-OUTn delay time t
d (dfo)
100 pF capacitance load: DF, OUTn 1.2 µs
Switching Characteristics at VDD= 5 V ± 10%, Ta = –20 to +75°C
Parameter Symbol Conditions
Ratings
Unit
min typ max
EIO output delay time t
d (eo)
30 pF capacitance load: LOAD, EIO1, EIO4 350 ns
LOAD-OUTn delay time t
d (ldo)
100 pF capacitance load: LOAD, OUTn 3 µs
DF-OUTn delay time t
d (dfo)
100 pF capacitance load: DF, OUTn 3 µs
Switching Characteristics at VDD= 3 to 4.5 V, Ta = 25°C ± 2°C
Page 4
No. 5279-4/8
LC4100C
Pin Functions
Symbol I/O Function
OUT1 to OUT240
V
0
V
1
V
4
V
5
V
EE1/VEE2
V
SS1/VSS2
DISP
DF
LOAD
L/R
CH120
EIO1 EIO3 EIO4
V
DD
V
SS
O
I I I I
– –
I I I I I
I/O
I
I/O
——Logic system power supply
Logic system ground
LCD drive outputs
Note: * don’t care (0 or 1). These values must be fixed at either 0 or 1.
V
0
level drive voltage input
V
1
level drive voltage input
All pins with the same name must be set to the same potential.
V
4
level drive voltage input
V
5
level drive voltage input
High-voltage block power supply. V
EE1
and V
EE2
must have the same potential.
High-voltage block ground. V
SS1
and V
SS2
must have the same potential.
All outputs will be held at a fixed V
5
level when this pin is low. Alternation input Data shift pulse input (falling edge) Data shift direction specification input High: 120
× 2, low: 240 ×1
Enable inputs and outputs
DF Data DISP OUTn
0 1 1 V
0
1 0 1 V
1
0 0 1 V
4
1 1 1 V
5
* * 0 V
5
L/R CH120 Shift direction
H L EIO1 OUT1 OUT240 EIO4 H H
EIO1 OUT1 OUT120 EIO3 OUT121 OUT240 EIO4
L L EIO1 OUT1 OUT240 EIO4 L H
EIO1 OUT1 OUT120 EIO3 OUT121 OUT240 EIO4
Page 5
Pad Assignment
No. 5279-5/8
LC4100C
Page 6
No. 5279-6/8
LC4100C
Pad Coordinates
Pad No. Signal X coordinate Y coordinate Pad No. Signal X coordinate Y coordinate
1 OUT1 –8365 897 51 OUT51 –4865 897 2 OUT2 –8295 727 52 OUT52 –4795 727 3 OUT3 –8225 897 53 OUT53 –4725 897 4 OUT4 –8155 727 54 OUT54 –4655 727 5 OUT5 –8085 897 55 OUT55 –4585 897 6 OUT6 –8015 727 56 OUT56 –4515 727 7 OUT7 –7945 897 57 OUT57 –4445 897 8 OUT8 –7875 727 58 OUT58 –4375 727
9 OUT9 –7805 897 59 OUT59 –4305 897 10 OUT10 –7735 727 60 OUT60 –4235 727 11 OUT11 –7665 897 61 OUT61 –4165 897 12 OUT12 –7595 727 62 OUT62 –4095 727 13 OUT13 –7525 897 63 OUT63 –4025 897 14 OUT14 –7455 727 64 OUT64 –3955 727 15 OUT15 –7385 897 65 OUT65 –3885 897 16 OUT16 –7315 727 66 OUT66 –3815 727 17 OUT17 –7245 897 67 OUT67 –3745 897 18 OUT18 –7175 727 68 OUT68 –3675 727 19 OUT19 –7105 897 69 OUT69 –3605 897 20 OUT20 –7035 727 70 OUT70 –3535 727 21 OUT21 –6965 897 71 OUT71 –3465 897 22 OUT22 –6895 727 72 OUT72 –3395 727 23 OUT23 –6825 897 73 OUT73 –3325 897 24 OUT24 –6755 727 74 OUT74 –3255 727 25 OUT25 –6685 897 75 OUT75 –3185 897 26 OUT26 –6615 727 76 OUT76 –3115 727 27 OUT27 –6545 897 77 OUT77 –3045 897 28 OUT28 –6475 727 78 OUT78 –2975 727 29 OUT29 –6405 897 79 OUT79 –2905 897 30 OUT30 –6335 727 80 OUT80 –2835 727 31 OUT31 –6265 897 81 OUT81 –2765 897 32 OUT32 –6195 727 82 OUT82 –2695 727 33 OUT33 –6125 897 83 OUT83 –2625 897 34 OUT34 –6055 727 84 OUT84 –2555 727 35 OUT35 –5985 897 85 OUT85 –2485 897 36 OUT36 –5915 727 86 OUT86 –2415 727 37 OUT37 –5845 897 87 OUT87 –2345 897 38 OUT38 –5775 727 88 OUT88 –2275 727 39 OUT39 –5705 897 89 OUT89 –2205 897 40 OUT40 –5635 727 90 OUT90 –2135 727 41 OUT41 –5565 897 91 OUT91 –2065 897 42 OUT42 –5495 727 92 OUT92 –1995 727 43 OUT43 –5425 897 93 OUT93 –1925 897 44 OUT44 –5355 727 94 OUT94 –1855 727 45 OUT45 –5285 897 95 OUT95 –1785 897 46 OUT46 –5215 727 96 OUT96 –1715 727 47 OUT47 –5145 897 97 OUT97 –1645 897 48 OUT48 –5075 727 98 OUT98 –1575 727 49 OUT49 –5005 897 99 OUT99 –1505 897 50 OUT50 –4935 727 100 OUT100 –1435 727
Continued on next page.
Page 7
No. 5279-7/8
LC4100C
Continued from preceding page.
Pad No. Signal X coordinate Y coordinate Pad No. Signal X coordinate Y coordinate
101 OUT101 –1365 897 151 OUT151 2135 897 102 OUT102 –1295 727 152 OUT152 2205 727 103 OUT103 –1225 897 153 OUT153 2275 897 104 OUT104 –1155 727 154 OUT154 2345 727 105 OUT105 –1085 897 155 OUT155 2415 897 106 OUT106 –1015 727 156 OUT156 2485 727 107 OUT107 –945 897 157 OUT157 2555 897 108 OUT108 –875 727 158 OUT158 2625 727 109 OUT109 –805 897 159 OUT159 2695 897 110 OUT110 –735 727 160 OUT160 2765 727 111 OUT111 –665 897 161 OUT161 2835 897 112 OUT112 –595 727 162 OUT162 2905 727 113 OUT113 –525 897 163 OUT163 2975 897 114 OUT114 –455 727 164 OUT164 3045 727 115 OUT115 –385 897 165 OUT165 3115 897 116 OUT116 –315 727 166 OUT166 3185 727 117 OUT117 –245 897 167 OUT167 3255 897 118 OUT118 –175 727 168 OUT168 3325 727 119 OUT119 –105 897 169 OUT169 3395 897 120 OUT120 –35 727 170 OUT170 3465 727 121 OUT121 35 897 171 OUT171 3535 897 122 OUT122 105 727 172 OUT172 3605 727 123 OUT123 175 897 173 OUT173 3675 897 124 OUT124 245 727 174 OUT174 3745 727 125 OUT125 315 897 175 OUT175 3815 897 126 OUT126 385 727 176 OUT176 3885 727 127 OUT127 455 897 177 OUT177 3955 897 128 OUT128 525 727 178 OUT178 4025 727 129 OUT129 595 897 179 OUT179 4095 897 130 OUT130 665 727 180 OUT180 4165 727 131 OUT131 735 897 181 OUT181 4235 897 132 OUT132 805 727 182 OUT182 4305 727 133 OUT133 875 897 183 OUT183 4375 897 134 OUT134 945 727 184 OUT184 4445 727 135 OUT135 1015 897 185 OUT185 4515 897 136 OUT136 1085 727 186 OUT186 4585 727 137 OUT137 1155 897 187 OUT187 4655 897 138 OUT138 1225 727 188 OUT188 4725 727 139 OUT139 1295 897 189 OUT189 4795 897 140 OUT140 1365 727 190 OUT190 4865 727 141 OUT141 1435 897 191 OUT191 4935 897 142 OUT142 1505 727 192 OUT192 5005 727
143 OUT143 1575 897 193 OUT193 5075 897 144 OUT144 1645 727 194 OUT194 5145 727 145 OUT145 1715 897 195 OUT195 5215 897 146 OUT146 1785 727 196 OUT196 5285 727 147 OUT147 1855 897 197 OUT197 5355 897 148 OUT148 1925 727 198 OUT198 5425 727 149 OUT149 1995 897 199 OUT199 5495 897 150 OUT150 2065 727 200 OUT200 5565 727
Continued on next page.
Page 8
No. 5279-8/8
LC4100C
This catalog provides information as of September, 1996. Specifications and information herein are subject to change without notice.
No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of which may directly or indirectly cause injury, death or property loss.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and
distributors and all their officers and employees, jointly and severally, against any and all claims and litigation and all damages, cost and expenses associated with such use:
Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on
SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties.
Continued from preceding page.
Pad No. Signal X coordinate Y coordinate Pad No. Signal X coordinate Y coordinate
201 OUT201 5635 897 232 OUT232 7805 727 202 OUT202 5705 727 233 OUT233 7875 897 203 OUT203 5775 897 234 OUT234 7945 727 204 OUT204 5845 727 235 OUT235 8015 897 205 OUT205 5915 897 236 OUT236 8085 727 206 OUT206 5985 727 237 OUT237 8155 897 207 OUT207 6055 897 238 OUT238 8225 727 208 OUT208 6125 727 239 OUT239 8295 897 209 OUT209 6195 897 240 OUT240 8365 727 210 OUT210 6265 727 241 V
EE1
8295 –886
211 OUT211 6335 897 242 V
0
7895 –863
212 OUT212 6405 727 243 V
1
7495 –859
213 OUT213 6475 897 244 V
5
7095 –859
214 OUT214 6545 727 245 V
4
6695 –859
215 OUT215 6615 897 246 V
SS1
6295 –859
216 OUT216 6685 727 247 V
DD
3295 –870 217 OUT217 6755 897 248 EIO4 –1295 –870 218 OUT218 6825 727 249 EIO3 –1495 –870 219 OUT219 6895 897 250 EIO1 –1895 –870 220 OUT220 6965 727 251 V
SS
–3095 –887 221 OUT221 7035 897 252 LOAD –3695 –870 222 OUT222 7105 727 253 DF –3895 –870 223 OUT223 7175 897 254 DISP –4095 –870 224 OUT224 7245 727 255 L/R –4495 –870 225 OUT225 7315 897 256 CH120 –4895 –870 226 OUT226 7385 727 257 V
SS2
–6295 –859 227 OUT227 7455 897 258 V
4
–6695 –859 228 OUT228 7525 727 259 V
5
–7095 –859 229 OUT229 7595 897 260 V
1
–7495 –859 230 OUT230 7665 727 261 V
0
–7895 –863 231 OUT231 7735 897 262 V
EE2
–8295 –886