Datasheet KBP10, KBP04, KBP06, KBP02, KBP005 Datasheet (INVAC)

...
Page 1
FEATURES
KBP0 SERIES
2.0 AMPERE SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE
50 to 1000 Volts PRV
CURRENT
2.0 Amperes
Plastic material has Underwriters Laboratory flammability classification 94V-0.
Low leakage. Surge overload rating - 50 amperes peak. Ideal for printed circuit boards. Exceeds environmental standards of
MIL - STD - 19500.
MECHANICAL DATA
Case
Terminals
Polarity Weight
: Reliable low cost construction utilizing
: moulded plastic technique results in : inexpensive product.
: Leads, solderable per MIL - STD - 202,
: Method 208.
: Polarity symbols printed on body. : 0.1 ounce, 2.8 grams.
+~~
Ø 0.8
2.1
18.0 max
Dimensions in millimetres
13.0 max
±
12.0 min
4.1
3.6
6.6 max
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
KBP08
800
800
Reformatted by Anglia 9907
Maximum Recurrent Peak Reverse Voltage Maximum Bridge Input Voltage RMS
Maximum DC Blocking Voltage Maximum Average Forward Current at
A = 25
T Peak Forward Surge Current, 8.3 ms single
half sine - wave superimposed on rated load Maximum Forward Voltage Drop
per Element at 1.0A Maximum Reverse Current at Rated DC
Blocking Voltage per Element Operating Temperature Range Storage Temperature Range
°C
(see Fig 4)
(see Fig 2)
(see Fig 1) (see Fig 3)
T
A = 25°C A = 100°C
T
V
RRM
VRMS
VDC
IF(AV)
IFSM
VF
IR
TJ
TSTG
KBP005
50 35 70 140 280 420 560 700
50
KBP01
100
100
KBP02
200
200
KBP04
400
400
2.0
50
1.1
10.0
1.0
- 55 to + 125
- 55 to + 150
KBP06
600
600
KBP10
1000
1000
V V
V A
A
V µA
mA °C °C
Page 2
RATING AND CHARACTERISTIC CURVES KBP0 SERIES
50
40
30
20
PEAK FORWARD SURGE
CURRENT, AMPERES
10
0
1 10 100
FIG 1 : MAXIMUM NON-REPETITIVE SURGE CURRENT PER ELEMENT
8.3ms Single Half Sine Wave TJ = 125°C
NUMBER OF CYCLES AT 60Hz
FIG 2 : DERATING CURVE FOR RECTIFIED OUTPUT CURRENT
2.0
1.5
1.0
.5
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
0
20 40 60 80 100 120 140
Resistive or Inductive Load
AMBIENT TEMPERATURE °C
INSTANTANEOUS FORWARD
CURRENT, AMPERES
FIG 3 : TYPICAL FORWARD CHARACTERISTICS PER ELEMENT
10
TJ = 25°C Pulse Width = 300µs
1.0
0.1
.01
0.4 0.6 0.8 1.0 1.2 1.4 INSTANTANEOUS FORWARD
VOLTAGE, VOLTS
FIG 4 : TYPICAL REVERSE CHARACTERISTICS PER ELEMENT
10
1.0
0.1
INSTANTANEOUS REVERSE
CURRENT, MICROAMPERES
.01
0 20 40 60 80 100 120 140
TJ = 100°C
TJ = 25°C
PERCENT OF RATED PEAK REVERSE VOLTAGE
Reformatted by Anglia 9907
Loading...